986 resultados para SMALL ANIMALS
Resumo:
The ovarian remnant syndrome (ORS) is an iatrogenic disorder in bitches and queens, which is characterized by recurrence of estrus following surgical spay, due to the presence of a piece of ovarian tissue within the abdominal cavity. In most cases, the remnant ovary is found in the right ovarian pedicle, due to its topographic position, deeper and more cranial than the left ovary. The main clinical signs of ORS in small animals are the heat behavior and the presence of vaginal swelling/secretion, especially in canines. The diagnosis should be performed by means of vaginal cytology when attraction of males is detected, serum estrogen and progesterone levels and/or by challenging test with GnRH or hCG administration. However, vaginal citology is the most suitable and less expensive diagnostic tool. Nowadays the treatment of choice is a new laparotomy or laparoscopy, followed by removal of the remnant ovarian tissue. The surgical treatment has more chances of success if it is performed in the diestrus (i.e., between 15 and 60 days after the detection of attraction of males). Furthermore, a careful and accurate surgical procedure aided by advanced visualization techniques during ovariohysterectomy or ovariectomy is the best way to prevent ORS in companion animals.
Resumo:
During the acute phase response, there is an increased production and release of certain proteins known as acute phase proteins (APPs) which can be produced by hepatocytes and peripheral tissues such as C-reactive protein (CRP), serum amyloid A (SAA), haptoglobin (Hp), alpha-1 acid glycoprotein (AGP). These proteins have been investigated as markers of various infectious diseases in small animals and the purpose of this review is to update the current knowledge about APPs in infectious diseases in dogs and cats.
Resumo:
Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT protocols for liver imaging in small animals. The purpose of this study is to assess the rule of MDCT in the characterization of hepatobiliary diseases in small animals; and to compare this method with conventional US. Candidates for this prospective study were 175 consecutive patients (dogs and cats) referred for evaluation of hepatobiliary disease. The patients underwent liver US and MDCT. Percutaneous needle biopsy was performed on all liver lesions or alterations encountered. As for gallbladder, histopatological evaluation was obtained from cholecystectomy specimens. Ultrasonographic findings in this study agreed well with those of previous reports. A protocol for dual-phase liver MDCT in small animals has been described. MDCT findings in parenchymal disorders of the liver, hepatic neoplasia and biliary disorders are here first described in dogs and cats and compared with the corresponding features in human medicine. The ability of MDCT in detection and characterization of hepatobiliary diseases in small animals is overall superior to conventional US. Ultrasonography and MDCT scanning, however, play complementary rules in the evaluation of these diseases. Many conditions have distinctive imaging features that may permit diagnosis. In most instances biopsy is required for definitive diagnosis.
Resumo:
Avulsion of nerve roots of the brachial plexus can be diagnosed clinically, neurologically, radiographically and by electromyography. But like the myelography these techniques are inprecise for determination of the severity (partial or complete disruption) and the localization of the lesion. In human medicine the combination of computerized tomography with myelography shows high accuracy. Veterinary reports of experience in this field are not yet known. The aim of the present study was to demonstrate nerve root avulsions using myelography and computerized tomography. Three dogs and one cat with traumatic lesions of the brachial plexus were examined. The lesion could be seen in all patients. Thus CT-myelography results in an improved prognostic assessment of brachial plexus paralysis. Moreover, this technique could become one of the most important diagnostic methods for brachial plexus lesions involving nerve root reinsertion--neurotizations in veterinary medicine.
Resumo:
A recombinant Mycobacterium bovis bacillus Calmette-Guérin (BCG) vector-based vaccine that secretes the V3 principal neutralizing epitope of human immunodeficiency virus (HIV) could induce immune response to the epitope and prevent the viral infection. By using the Japanese consensus sequence of HIV-1, we successfully constructed chimeric protein secretion vectors by selecting an appropriate insertion site of a carrier protein and established the principal neutralizing determinant (PND)-peptide secretion system in BCG. The recombinant BCG (rBCG)-inoculated guinea pigs were initially screened by delayed-type hypersensitivity (DTH) skin reactions to the PND peptide, followed by passive transfer of the DTH by the systemic route. Further, immunization of mice with the rBCG resulted in induction of cytotoxic T lymphocytes. The guinea pig immune antisera showed elevated titers to the PND peptide and neutralized HIVMN, and administration of serum IgG from the vaccinated guinea pigs was effective in completely blocking the HIV infection in thymus/liver transplanted severe combined immunodeficiency (SCID)/hu or SCID/PBL mice. In addition, the immune serum IgG was shown to neutralize primary field isolates of HIV that match the neutralizing sequence motif by a peripheral blood mononuclear cell-based virus neutralization assay. The data support the idea that the antigen-secreting rBCG system can be used as a tool for development of HIV vaccines.
Outline for a course in first aid for and control of small animals for use during the war emergency,
Resumo:
Cover title.
Resumo:
Sudden cardiac death in small animals is uncommon but often occurs due to cardiac conduction defects or myocardial diseases. Primary cardiac conduction defects are mainly caused by mutations in genes involved in impulse conduction processes (e.g., gapjunction genes and transcription factors) or repolarisation processes (e.g., ion-channel genes), whereas primary cardiomyopathies are mainly caused by defective force generation or force transmission due to gene mutations in either sarcomeric or cytoskeleton proteins. Although over 50 genes have been identified in humans directly or indirectly related to sudden cardiac death, no genetic aetiologies have been identified in small animals. Sudden cardiac deaths have been also reported in German Shepherds and Boxers. A better understanding of molecular genetic aetiologies for sudden cardiac death will be required for future study toward unveiling actiology in sudden cardiac death in small animals. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.
Resumo:
The presence of anti-Toxoplasma gondii IgM and IgG antibodies was studied in samples of blood serum taken from eighty dogs with nervous symptoms at the Serviço de Enfermidades Infecciosas dos Animais, Faculdade de Medicina Veterinária e Zootecnia, Unesp, Botucatu, São Paulo, Brazil. The frequency of IgG titers were 16 (13.7%), 64 (13.7%), and 256 (5%), and for IgM titers were 16 (7.5%), 64 (15%), and 256 (8.7%). Positive reactions were more frequent in the older animals, males, from a rural environment, in constant contact with small animals, principally birds and rodents. There was a higher frequency of a positive reaction in dogs fed with kitchen food, especially in those fed with raw ingredients. The most common neurological pictures were alterations in consciousness, in movement, and in the hand-cart test. The percentage of reagents with specific IgM antibodies was high, indicating active infections, but the possibility of co-infection with the distemper virus can not be discarded, and this may be a predisposing factor for toxoplasmosis infection, once the distemper virus has a potent immunosupressive action.
Resumo:
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.
Resumo:
The presence of anti-Toxoplasma gondii IgM and IgG antibodies was studied in samples of blood serum taken from eighty dogs with nervous symptoms at the Serviço de Enfermidades Infecciosas dos Animais, Faculdade de Medicina Veterinária e Zootecnia, Unesp, Botucatu, São Paulo, Brazil. The frequency of IgG titers were 16 (13.7%), 64 (13.7%), and 256 (5%), and for IgM titers were 16 (7.5%), 64 (15%), and 256 (8.7%). Positive reactions were more frequent in the older animals, males, from a rural environment, in constant contact with small animals, principally birds and rodents. There was a higher frequency of a positive reaction in dogs fed with kitchen food, especially in those fed with raw ingredients. The most common neurological pictures were alterations in consciousness, in movement, and in the hand-cart test. The percentage of reagents with specific IgM antibodies was high, indicating active infections, but the possibility of co-infection with the distemper virus can not be discarded, and this may be a predisposing factor for toxoplasmosis infection, once the distemper virus has a potent immunosupressive action.