768 resultados para Retest Reliability
Resumo:
Accurate monitoring of prevalence and trends in population levels of physical activity (PA) is a fundamental public health need. Test-retest reliability (repeatability) was assessed in population samples for four self-report PA measures: the Active Australia survey (AA, N=356), the short International Physical Activity Questionnaire (IPAQ, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and in the Australian National Health Survey (NHS, N=122). Percent agreement and Kappa statistics were used to assess reliability of classification of activity status as 'active', 'insufficiently active' or 'sedentary'. Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and for total minutes. Percent agreement scores for activity status were very good on all four instruments, ranging from 60% for the NHS to 79% for the IPAQ. Corresponding Kappa statistics ranged from 0.40 (NHS) to 0.52 (AA). For individual items, ICCs were highest for walking (0.45 to 0.78) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity.
Resumo:
PURPOSE Accurate monitoring of prevalence and trends in population levels of physical activity is fundamental to the planning of health promotion and disease-prevention strategies. Test-retest reliability (repeatability) was assessed for four self-report measures of physical activity commonly used in population surveys: the Active Australia survey (AA, N=356), the short form of the International Physical Activity Questionnaire (IPAQ-S, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and the physical activity items in the Australian National Health Survey (NHS, N=122). METHODS Percent agreement and Kappa statistics were used to assess the reliability of classification of activity status (where ‘active’= 150 minutes of activity per week) and sedentariness (where ‘sedentary’ = reporting no physical activity). Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and on total minutes reported in each survey. RESULTS Percent agreement scores for both activity status and sedentariness were very good on all four instruments. Overall the percent agreement between repeated surveys was between 73% (NHS) and 87% (IPAQ) for the criterion measure of achieving 150 minutes per week, and between 77% (NHS) and 89% (IPAQ) for the criterion of being sedentary. Corresponding Kappa statistics ranged from 0.46 (NHS) to 0.61 (AA) for activity status and from 0.20 (BRFSS) to 0.52 (AA) for sedentariness. For the individual items ICCs were highest for walking (0.45 to 0.56) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). CONCLUSION All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity. Supported by the Australian Commonwealth Department of Health and Ageing.
Resumo:
The human connectome has recently become a popular research topic in neuroscience, and many new algorithms have been applied to analyze brain networks. In particular, network topology measures from graph theory have been adapted to analyze network efficiency and 'small-world' properties. While there has been a surge in the number of papers examining connectivity through graph theory, questions remain about its test-retest reliability (TRT). In particular, the reproducibility of structural connectivity measures has not been assessed. We examined the TRT of global connectivity measures generated from graph theory analyses of 17 young adults who underwent two high-angular resolution diffusion (HARDI) scans approximately 3 months apart. Of the measures assessed, modularity had the highest TRT, and it was stable across a range of sparsities (a thresholding parameter used to define which network edges are retained). These reliability measures underline the need to develop network descriptors that are robust to acquisition parameters.
Resumo:
The aims of this study were to 1) determine the relationship between performance on the court-based TIVRE-Basket® test and peak aerobic power determined from a criterion lab-based incremental treadmill test and 2) to examine the test-retest reliability of the TIVRE-Basket® test in elite male basketball players. To address aim 1, 36 elite male basketball players (age 25.2 + 4.7 years, weight 94.1 + 11.4 kg, height 195.83 + 9.6 cm) completed a graded treadmill exercise test and the TIVRE-Basket® within 72 hours. Mean distance recorded during the TIVRE-Basket® test was 4001.8 + 176.4m, and mean VO2 peak was 54.7 + 2.8 ml.kg.min-1, and the correlation between the two parameters was r=0.824 (P= <0.001). Linear regression analysis identified TIVRE-Basket® distance (m) as the only unique predictor of VO2 peak in a single variable plus constant model: VO2 peak = 2.595 + ((0.13* TIVRE-Basket® distance (m)). Performance on the TIVRE-Basket® test accounted for 67.8% of the variance in VO2 peak (t=8.466, P=<.001, 95% CI 0.01 - 0.016, SEE 1.61). To address aim 2, 20 male basketball players (age 26.7±4.2; height 1.94±0.92; weight 94.0±9.1) performed the TIVRE-Basket® test on two occasions. There was no significant difference in total distance covered between Trial 1 (4138.8 + 677.3m) and Trial 2 (4188.0 + 648.8m; t = 0.5798, P = 0.5688). Mean difference between trials was 49.2 + 399.5m, with an ICC of 0.85 suggesting a moderate level of reliability. Standardised TEM was 0.88%, representing a moderate degree of trial to trial error, and the CV was 6.3%. The TIVRE-Basket® test therefore represents a valid and moderately reliable court-based sport-specific test of aerobic power for use with individuals and teams of elite level male basketball players. Future research is required to ascertain its validity and reliability in other basketball populations e.g. across age groups, at different levels of competition, in females and in different forms of the game e.g. wheelchair basketball.
Resumo:
This paper studies the test-retest reliability of distortion product otoacoustic emissions (DPOAE) in newborns in a neonatal intensive care unit.
Resumo:
This paper is a review of a study to measure acoustic impedance of the ear using a Madsen ZO70 bridge model.
Resumo:
The primary objective of this research study is to determine which form of testing, the PEST algorithm or an operator-controlled condition is most accurate and time efficient for administration of the gaze stabilization test
Resumo:
Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)