901 resultados para Resistance to penetration


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of different methods of soil preparation on soil moisture loss, weed growth and soil resistance to penetration has been quantified for the Latosols of Bebedouro experiment station of CPATSA-EMBRAPA, Petrolina,PE, Brazil. The methods studied are manual preparation, preparation by animal drawn wheeled tool carrier and tractorized implements. The drying characteristics of three fields with different soil physical properties were studied prior to conducting the experiment. The different methods of soil preparation caused the soil moisture loss differently. The plot prepared by animal drawn tool carrier retained more moisture for longer time even at deeper layers. The soil resistance to penetration on the surface increased with time with little variation at deeper layers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental study to evaluate effect of cumulative lightweight aggregate (LWA) content (including lightweight sand) in concrete [water/cement ratio (w/c) = 0.38] on its water absorption, water permeability, and resistance to chloride-ion penetration. Rapid chloride penetrability test (ASTM C 1202), rapid migration test (NT Build 492), and salt ponding test (AASHTO T 259) were conducted to evaluate the concrete resistance to chloride-ion penetration. The results were compared with those of a cement paste and a control normal weight aggregate concrete (NWAC) with the same w/c and a NWAC (w/c = 0.54) with 28-day compressive strength similar to some of the lightweight aggregate concrete (LWAC). Results indicate that although the total charge passed, migration coefficient, and diffusion coefficient of the LWAC were not significantly different from those of NWAC with the same w/c of 0.38, resistance of the LWAC to chloride penetration decreased with increase in the cumulative LWA content in the concretes. The water penetration depth under pressure and water sorptivity showed, in general, similar trends. The LWAC with only coarse LWA had similar water sorptivity, water permeability coefficient, and resistance to chloride-ion penetration compared to NWAC with similar w/c. The LWAC had lower water sorptivity, water permeability and higher resistance to chloride-ion penetration than the NWAC with similar 28-day strength but higher w/c. Both the NWAC and LWAC had lower sorptivity and higher resistance to chloride-ion penetration than the cement paste with similar w/c.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental study to evaluate the influence of coarse lightweight aggregate (LWA), fine LWA and the quality of the paste matrix on water absorption and permeability, and resistance to chloride-ion penetration in concrete. The results indicate that incorporation of pre-soaked coarse LWA in concrete increases water sorptivity and permeability slightly compared to normal weight concrete (NWC) of similar water-to-cementitious materials ratio (w/cm). Furthermore, resistance of the sand lightweight concrete (LWC) to water permeability and chloride-ion penetration decreases with an increase in porosity of the coarse LWA. The use of fine LWA including a crushed fraction <1.18 mm reduced resistance of the all-LWC to water and chloride-ion penetration compared with the sand-LWC which has the same coarse LWA. Overall, the quality of the paste matrix was dominant in controlling the transport properties of the concrete, regardless of porosity of the aggregates used. With low w/cm and silica fume, low unit weight LWC (_1300 kg/m3) was produced with a higher resistance to water and chloride-ion penetration compared with NWC and LWC of higher unit weights.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental study on the resistance of lightweight aggregate concretes to chloride-ion penetration in comparison to that of normal weight concrete of similar w/c. Salt ponding test (based on AASHTO T 259), rapid chloride permeability test (ASTM C 1202) and rapid migration test (NT Build 492) were carried out to evaluate the concrete resistance to the chloride-ion penetration. Results indicate that in general the resistance of the LWAC to the chloride-ion penetration was in the same order as that of NWAC of similar w/c. However, the increase in cumulative LWA volume and the incorporation of finer LWA particles led to higher charge passed, migration coefficient, and diffusion coefficient. Since the LWACs had lower 28-day compressive strength compared with that of the NWAC of similar w/c, the LWACs may have equal or better resistance to the chloride-ion penetration compared with the NWAC of equivalent strength. The trend of the resistance of concretes to chloride-ion penetration determined by the three test methods was reasonably consistent although there were some discrepancies due to different test methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To ensure better concrete quality and long-term durability, there has been an increasing focus in recent years on the development of test methods for quality control of concrete. This paper presents a study to evaluate the effect of water accessible porosity and oven-dry unit weight on the resistance of concrete to chloride-ion penetration. Based on the experimental results and regression analyses, empirical relationships of the charge passed (ASTM C 1202) and chloride migration coefficient (NT Build 492) versus the water accessible porosity and oven dry unit weight of the concrete are established. Using basic physical properties of water accessible porosity and oven dry unit weight which can be easily determined, total charge passed and migration coefficient of the concrete can be estimated for quality control and for estimating durability of concrete.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental study to evaluate the effect of coarse and fine LWA in concrete on its water absorption and permeability, and resistance to chloride-ion penetration. In additions, LWC with lower unit weight of about 1300 kg/m3 but high resistance to water and chloride-ion penetration was developed and evaluated. The results indicate that the incorporation of coarse LWA in concrete increases water sorptivity and permeability slightly compared to NWC of similar w/c. The resistance of the sand-LWC to chloride-ion penetration depends on porosity of the coarse LWA. Fine LWA has more influence on the transport proper-ties of concrete than coarse LWA. Use of lightweight crushed sand <1.18 mm reduced the resistance of the LWC to water and chloride-ion penetration to some extent. With low w/cm and silica fume, low unit weight LWC (~1300 kg/m3) was produced with higher resistance to water and chloride ion penetration compared with concretes of higher unit weights.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is an invited contribution in a special issue of the Journal of Cement and Concrete Composites

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mining process promotes land modification and complete landscape alteration. Those alterations in the surface are shown more obviously in the aesthetical aspect as the visual elements of form, texture, climbs, complexity and color which composes the landscape. As a consequence, mining has impacts on the topography, in the soil, in the vegetation and in the area's drainage, with a direct influence on the enterprise. A quite common problem in the recovery of degraded areas in mineral exploration is the compaction of the soil due to the intense traffic of machines and earth movement. The most common problem of the compaction of a degraded surface is an increase of the mechanical resistance to the penetration of plant roots, a reduction of the aeration, an alteration of the flow of water and heat, also in the availability of water and nutrients. Thus, the present work had the basic objective of diagnosing the compaction of an area degraded by mining in a spacial way, through the mechanical resistance and the penetration, to guide the future subsoiling in the area requiring recovery. Through the studies, it was concluded that the krigagem method in agreement with the space variation allows the division of the area under study into sub areas facilitating a future work to reduce costs and unnecessary interference to the atmosphere. The method was shown to be quite appropriate and it can be used in the diagnosis of compaction in a degraded area by mining, foreseeing the subsoiling requirement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Monosporascus cannonballus is the main causal agent of melon vine decline disease. Several studies have been carried out mainly focused on the study of the penetration of this pathogen into melon roots, the evaluation of symptoms severity on infected roots, and screening assays for breeding programs. However, a detailed molecular view on the early interaction between M. cannonballus and melon roots in either susceptible or resistant genotypes is lacking. In the present study, we used a melon oligo-based microarray to investigate the gene expression responses of two melon genotypes, Cucumis melo 'Piel de sapo' ('PS') and C. melo 'Pat 81', with contrasting resistance to the disease. This study was carried out at 1 and 3 days after infection (DPI) by M. cannonballus. Results: Our results indicate a dissimilar behavior of the susceptible vs. the resistant genotypes from 1 to 3 DPI. 'PS' responded with a more rapid infection response than 'Pat 81' at 1 DPI. At 3 DPI the total number of differentially expressed genes identified in 'PS' declined from 451 to 359, while the total number of differentially expressed transcripts in 'Pat 81' increased from 187 to 849. Several deregulated transcripts coded for components of Ca2+ and jasmonic acid (JA) signalling pathways, as well as for other proteins related to defence mechanisms. Transcriptional differences in the activation of the JA-mediated response in 'Pat 81' compared to 'PS' suggested that JA response might be partially responsible for their observed differences in resistance. Conclusions: As a result of this study we have identified for the first time a set of candidate genes involved in the root response to the infection of the pathogen causing melon vine decline. This information is useful for understanding the disease progression and resistance mechanisms few days after inoculation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi analizar a distribuição espacial da compactação do solo e a influência da umidade do solo na resistência à penetração. Esta última variável foi descrita pelo índice de cone. O solo estudado foi Nitossolo e os dados de índice de cone foram obtidos usando um penetrômetro. A resistência do solo foi avaliada a 5 profundidades diferentes, 0-10 cm, 10-20 cm, 20-30 cm, 30-40 cm e mais de 40 cm, porém o conteúdo de umidade do solo foi medido a 0-20 cm e 20-40 cm. As condições hídricas do solo variaram nas diferentes amostragems. Os coeficientes de variação para o índice de cone foram 16,5% a 45,8% e os do conteúdo de umidade do solo variaram entre 8,96% e 21,38%. Os resultados sugeriram elevada correlação entre a resistência do solo, estimada pelo índice de cone e a profundidade do solo. Sem embargo, a relação esperada com a umidade do solo não foi apreciada. Observou-se dependência espacial em 31 de 35 séries de dados de índice de cone e umidade do solo. Esta dependência foi ajustada por modelos exponenciais com efeito pepita variável de 0 a 90% o valor do patamar. em séries de dados o comportamento foi aleatório. Portanto, a técnica das distâncias inversas foi utilizada para cartografar a distribuição das variáveis que não tiveram estrutura espacial. Na krigagem constatou-se uma suavização dos mapas comparados com esses das distâncias inversas. A krigagem indicadora foi utilizada para cartografar a variabilidade espacial do índice de cone e recomendar melhor manejo do solo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A herança da resistência ao oídio na cultivar de ervilha MK-10 e alguns aspectos histológicos da infecção foram estudados. Para o estudo da herança, as gerações F1, F2, retrocuzamentos e geração F3 de MK-10 com duas populações suscetíveis foram avaliadas. Nas avaliações histológicas observou-se a porcentagem de conídios germinados, porcentagem de conídios que formaram apressório, porcentagem de conídios que estabeleceram colônia e número de haustórios por colônia. Para comparar as razões de segregação obtidas no estudo da herança da resistência, adotou-se o teste do Qui-quadrado (X²) e para os dados das análises histológicas, utilizou-se o teste Tukey a 5% de probabilidade. Concluiu-se que a resistência de MK-10 ao oídio é devida a um par de alelos recessivos e que a resistência é expressa na fase de pré-penetração, completada por uma morte celular localizada pós-penetração, característica da presença do par de alelos recessivos er1er1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inheritance of resistance to powdery mildew in the pea cultivar MK-10 and some histological aspects of infection were assessed. For the inheritance study, F1, F2, backcrosses and F3 generations of MK-10 crossed with two susceptible populations were evaluated. Histological evaluations included percentage of germinated conidia, percentage of conidia that formed appresoria, percentage of conidia that established colonies, and number of haustoria per colony. Segregation ratios obtained in the resistance inheritance study were compared by Chi-square (ײ) test and the histological data were analyzed by Tukey's test at 5% probability. It was concluded that resistance of MK-10 to powdery mildew is due to a pair of recessive alleles since it is expressed in the pre-penetration stage and completed by post-penetration localized cellular death, characteristic of the presence of the pair of recessive alleles er1er1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Benzo-(1,2,3)-thiadiazole-7-carbothioic acid S-methyl ester (BTH), a synthetic chemical, was applied as a foliar spray to tomato (Lycopersicon esculentum) plants and evaluated for its potential to confer increased resistance against the soil-borne pathogen Fusarium oxysporum f. sp. radicis-lycopersici (FORL). In nontreated tomato plants all root tissues were massively colonized by FORL hyphae. Pathogen ingress toward the vascular stele was accompanied by severe host cell alterations, including cell wall breakdown. In BTH-treated plants striking differences in the rate and extent of fungal colonization were observed. Pathogen growth was restricted to the epidermis and the outer cortex, and fungal ingress was apparently halted by the formation of callose-enriched wall appositions at sites of fungal penetration. In addition, aggregated deposits, which frequently established close contact with the invading hyphae, accumulated in densely colonized epidermal cells and filled most intercellular spaces. Upon incubation of sections with gold-complexed laccase for localization of phenolic-like compounds, a slight deposition of gold particles was observed over both the host cell walls and the wall appositions. Labeling was also detected over the walls of fungal cells showing signs of obvious alteration ranging from cytoplasm disorganization to protoplasm retraction. We provide evidence that foliar applications of BTH sensitize susceptible tomato plants to react more rapidly and more efficiently to FORL attack through the formation of protective layers at sites of potential fungal entry.