948 resultados para Radio waves
Resumo:
The equations of Milsom are evaluated, giving the ground range and group delay of radio waves propagated via the horizontally stratified model ionosphere proposed by Bradley and Dudeney. Expressions for the ground range which allow for the effects of the underlying E- and F1-regions are used to evaluate the basic maximum usable frequency or M-factors for single F-layer hops. An algorithm for the rapid calculation of the M-factor at a given range is developed, and shown to be accurate to within 5%. The results reveal that the M(3000)F2-factor scaled from vertical-incidence ionograms using the standard URSI procedure can be up to 7.5% in error. A simple addition to the algorithm effects a correction to ionogram values to make these accurate to 0.5%.
Resumo:
"ASTIA document no. AD 117044."
Resumo:
Mode of access: Internet.
Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.
Resumo:
OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.
Resumo:
We investigated the association between exposure to radio-frequency electromagnetic fields (RF-EMFs) from broadcast transmitters and childhood cancer. First, we conducted a time-to-event analysis including children under age 16 years living in Switzerland on December 5, 2000. Follow-up lasted until December 31, 2008. Second, all children living in Switzerland for some time between 1985 and 2008 were included in an incidence density cohort. RF-EMF exposure from broadcast transmitters was modeled. Based on 997 cancer cases, adjusted hazard ratios in the time-to-event analysis for the highest exposure category (>0.2 V/m) as compared with the reference category (<0.05 V/m) were 1.03 (95% confidence interval (CI): 0.74, 1.43) for all cancers, 0.55 (95% CI: 0.26, 1.19) for childhood leukemia, and 1.68 (95% CI: 0.98, 2.91) for childhood central nervous system (CNS) tumors. Results of the incidence density analysis, based on 4,246 cancer cases, were similar for all types of cancer and leukemia but did not indicate a CNS tumor risk (incidence rate ratio = 1.03, 95% CI: 0.73, 1.46). This large census-based cohort study did not suggest an association between predicted RF-EMF exposure from broadcasting and childhood leukemia. Results for CNS tumors were less consistent, but the most comprehensive analysis did not suggest an association.
Resumo:
A ressonância magnética é a propriedade física exibida por núcleos de determinados elementos que, quando submetidos a um campo magnético forte e excitados por ondas de rádio em determinada freqüência (Freqüência de Larmor), emitem rádio sinal, o qual pode ser captado por uma antena e transformado em imagem. A imagem por ressonância magnética (IRM) é o método de diagnóstico por imagem não-invasivo mais sensível para avaliar partes moles, particularmente o encéfalo, porém trata-se de uma técnica onerosa. Ela apresenta grande potencial diagnóstico, poucos efeitos deletérios e muitos benefícios a serem obtidos com o seu uso. Além disso, a IRM fornece informações anatômicas acuradas, imagens em qualquer plano do corpo, bom contraste e resolução espacial e por si só pode sugerir um diagnóstico. Porém, não permite um diagnóstico histológico específico e deve ser interpretada em contexto com outros achados clínicos e patológicos. Esta revisão teve como objetivos mostrar as bases físicas da ressonância magnética e propiciar mais conhecimento aos veterinários.
Resumo:
Magnetic resonance imaging (MRI) relies on the physical properties of unpaired protons in tissues to generate images. Unpaired protons behave like tiny bar magnets and will align themselves in a magnetic field. Radiofrequency pulses will excite these aligned protons to higher energy states. As they return to their original state, they will release this energy as radio waves. The frequency of the radio waves depends on the local magnetic field and by varying this over a subject, it is possible to build the images we are familiar with. In general, MRI has not been sufficiently sensitive or specific in the assessment of diffuse liver disease for clinical use. However, because of the specific characteristics of fat and iron, it may be useful in the assessment of hepatic steatosis and iron overload. Magnetic resonance imaging is useful in the assessment of focal liver disease, particularly in conjunction with contrast agents. Haemangiomas have a characteristic bright appearance on T-2 weighted images because of the slow flowing blood in dilated sinusoids. Focal nodular hyperplasia (FNH) has a homogenous appearance, and enhances early in the arterial phase after gadolinium injection, while the central scar typically enhances late. Hepatic adenomas have a more heterogenous appearance and also enhance in the arterial phase, but less briskly than FNH. Hepatocellular carcinoma is similar to an adenoma, but typically occurs in a cirrhotic liver and has earlier washout of contrast. The appearance of metastases depends on the underlying primary malignancy. Overall, MRI appears more sensitive and specific than computed tomography with contrast for the detection and evaluation of malignant lesions. (C) 2000 Blackwell Science Asia Pty Ltd.
Resumo:
A T(2) magnetization-preparation (T(2) Prep) sequence is proposed that is insensitive to B(1) field variations and simultaneously provides fat suppression without any further increase in specific absorption rate (SAR). Increased B(1) inhomogeneity at higher magnetic field strength (B(0) > or = 3T) necessitates a preparation sequence that is less sensitive to B(1) variations. For the proposed technique, T(2) weighting in the image is achieved using a segmented B(1)-insensitive rotation (BIR-4) adiabatic pulse by inserting two equally long delays, one after the initial reverse adiabatic half passage (AHP), and the other before the final AHP segment of a BIR-4 pulse. This sequence yields T(2) weighting with both B(1) and B(0) insensitivity. To simultaneously suppress fat signal (at the cost of B(0) insensitivity), the second delay is prolonged so that fat accumulates additional phase due to its chemical shift. Numerical simulations as well as phantom and in vivo image acquisitions were performed to show the efficacy of the proposed technique.
Resumo:
In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.
Resumo:
RFID-tekniikka on radiotaajuudella toimivaa etätunnistusta, jossa hyödynnetään RFID-tunnisteiksi kutsuttuja tageja, sekä RFID-lukijoita. RFID-tekniikan käyttökohteet ovat erittäin laajat. Tässä kandidaatintyössä tutkitaan RFID-tekniikan hyödyntämismahdollisuuksia teollisuuden huoltopalvelusuhteessa. Työ keskittyy huollettavien laitteiden etätunnistamiseen mobiileja RFID-lukijoita hyödyntäen. Laitteiden tiedot noudetaan olemassa olevasta tietokannasta web-käyttöliittymän kautta. Koska laitteet koostuvat pääosin metallista, joudutaan tunnistetyyppien valintaa pohtimaan tarkasti. Metallipinnat sekä nesteet vaikuttavat erittäin negatiivisesti useiden tunnisteiden lukuetäisyyteen. Työssä keskitytään vaadittavan järjestelmän suunnittelemiseen aikaisempia tutkimuksia hyödyntäen, mutta itse järjestelmän toteutus ei kuulu tähän kandidaatintyöhön. Lopussa järjestelmän alustava suunnitelma esitellään.
Resumo:
Tekniikan kehityksen myötä reaalimaailman ilmiöitä voidaan mallintaa yhä tarkemmin. Tässä työssä tutkitaan VIRVE-radioverkon tukiaseman peittoalueen mallintamista. Työn tavoitteena oli mallintaa VIRVE-tukiaseman peittoalue mahdollisimman tarkasti. Tavoitteena oli myös löytää VIRVE-tukiasemaan peittoalueen kannalta nykyistä paremmat antenniratkaisut. Tutkimuksen teoreettisessa osuudessa selvitettiin tukiaseman peittoalueen mallintamiseen liittyviä tekijöitä, kuten radioaaltojen ominaisuuksia ja etenemismalleja sekä antennien teoriaa. Eri etenemismalleilla laskettuja tukiasemien peittoennusteita verrattiin empiirisesti toteutettuihin tukiasemien peittoalueiden mittaustuloksiin. Työn tuloksena löydettiin radioaaltojen etenemismalli, jolla mallinnettavien tukiasemien peittoalue-ennusteet vastasivat hyvin empiirisesti mitattuja tuloksia. Lisäksi löydettiin nykyistä paremmat antenniratkaisut VIRVE-tukiasemiin.
Resumo:
RFID on radioaaltoja hyväksikäyttävä langaton kommunikointitekniikka, jota käytetään tunnistamaan tunnisteella merkittyjä esineitä tai ihmisiä yksilöinä. RFID on jo pitkään ollut tunnettu tekniikka, mutta vasta viime vuosikymmeninä sitä on alettu hyödyntämään kaupallisesti eri sovellusaloilla. Kandidaatintyön tarkoituksena on tehdä yleiskatsaus RFID:n historiaan, järjestelmien osiin ja niiden toimintaan sekä kartoittaa RFID-markkinoiden nykytilaa ja lähitulevaisuutta sekä globaalilta kannalta että Suomessa. Lopuksi työssä tarkastellaan RFID-perusteisten kulunvalvontajärjestelmien perusominaisuuksia ja niiden toimintaa.
Resumo:
We propose a mechanism to explain suggested links between seismic activity and ionospheric changes detected overhead. Specifically, we explain changes in the natural extremely low-frequency (ELF) radio noise recently observed in the topside ionosphere aboard the DEMETER satellite at night, before major earthquakes. Our mechanism utilises increased electrical conductivity of surface layer air before a major earthquake, which reduces the surface-ionosphere electrical resistance. This increases the vertical fair weather current, and (to maintain continuity of electron flow) lowers the ionosphere. Magnitudes of crucial parameters are estimated and found to be consistent with observations. Natural variability in ionospheric and atmospheric electrical properties is evaluated, and may be overcome using a hybrid detection approach. Suggested experiments to investigate the mechanism involve measuring the cut-off frequency of ELF “tweeks”, the amplitude and phase of very low frequency radio waves in the Earth–ionosphere waveguide, or medium frequency radar, incoherent scatter or rocket studies of the lower ionospheric electron density.
Resumo:
I was born human. But this was an accident of fate - a condition merely of time and place. I believe it's something we have the power to change. I will tell you why. In August 1998, a silicon chip was implanted in my arm, allowing a computer to monitor me as I moved through the halls and offices of the Department of Cybernetics at the University of Reading, just west of London, where I've been a professor since 1988. My implant communicated via radio waves with a network of antennas throughout the department that in turn transmitted the signals to a computer programmed to respond to my actions. At the main entrance, a voice box operated by the computer said "Hello" when I entered; the computer detected my progress through the building, opening the door to my lab for me as I approached it and switching on the lights. For the nine days the implant was in place, I performed seemingly magical acts simply by walking in a particular direction. The aim of this experiment was to determine whether information could be transmitted to and from an implant. Not only did we succeed, but the trial demonstrated how the principles behind cybernetics could perform in real-life applications.
Resumo:
The temporal variability of the atmosphere through which radio waves pass in the technique of differential radar interferometry can seriously limit the accuracy with which the method can measure surface motion. A forward, nested mesoscale model of the atmosphere can be used to simulate the variable water content along the radar path and the resultant phase delays. Using this approach we demonstrate how to correct an interferogram of Mount Etna in Sicily associated with an eruption in 2004-5. The regional mesoscale model (Unified Model) used to simulate the atmosphere at higher resolutions consists of four nested domains increasing in resolution (12, 4, 1, 0.3 km), sitting within the analysis version of a global numerical model that is used to initiate the simulation. Using the high resolution 3D model output we compute the surface pressure, temperature and the water vapour, liquid and solid water contents, enabling the dominant hydrostatic and wet delays to be calculated at specific times corresponding to the acquisition of the radar data. We can also simulate the second-order delay effects due to liquid water and ice.