979 resultados para QT DISPERSION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE - Studies have shown that therapy with beta-blockers reduces mortality in patients with heart failure. However, there are no studies describing the effects of propranolol on the QT dispersion in this population. The objective of this study was to assess the electrophysiological profile, mainly QT dispersion, of patients with heart failure regularly using propranolol. METHODS - Fifteen patients with heart failure and using propranolol were assessed over a period of 12 months. Twelve-lead electrocardiograms (ECG) were recorded prior to the onset of beta-blocker therapy and after 3 months of drug use. RESULTS - A significant reduction in heart rate, in QT dispersion and in QTc dispersion was observed, as was also an increase in the PR interval and in the QT interval, after the use of propranolol in an average dosage of 100 mg/day. CONCLUSION - Reduction in QT dispersion in patients with heart failure using propranolol may explain the reduction in the risk of sudden cardiac death with beta-blocker therapy, in this specific group of patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Parasympathetic dysfunction is an independent risk factor in individuals with coronary artery disease, and cholinergic stimulation is a potential therapeutical option. We determined the effects of pyridostigmine bromide, a reversible anticholinesterase agent, on electrocardiographic variables of healthy individuals. METHODS: We carried out a cross-sectional, double blind, randomized, placebo-controlled study. We obtained electrocardiographic tracings in 12 simultaneous leads of 10 healthy young individuals at rest before and after oral administration of 45 mg of pyridostigmine or placebo. RESULTS: Pyridostigmine increased RR intervals (before: 886±27 ms vs after: 1054±37 ms) and decreased QTc dispersion (before: 72±9ms vs after: 45±3ms), without changing other electrocardiographic variables (PR segment, QT interval, QTc, and QT dispersion). CONCLUSION: Bradycardia and the reduction in QTc dispersion induced by pyridostigmine may effectively represent a protective mechanism if these results can be reproduced in individuals with cardiovascular diseases.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between P-wave and QT dispersions in elderly patients with heart failure. METHODS: Forty-seven elderly patients (75.6±6 years) with stable heart failure in NYHA functional classes II or III and with ejection fractions of 37±6% underwent body surface mapping to analyze P-wave and QT dispersions. The degree of correlation between P-wave and QT dispersions was assessed, and P-wave dispersion values in patients with QT dispersion greater than and smaller than 100 ms were compared. RESULTS: The mean values of P-wave and QT dispersions were 54±14 ms and 68±27 ms, respectively. The correlation between the 2 variables was R=0.41 (p=0.04). In patients with QT dispersion values > 100 ms, P-wave dispersion was significantly greater than in those with QT dispersion values < 100 ms (58±16 vs 53±12 ms, p=0.04 ). CONCLUSION: Our results suggest that, in elderly patients with heart failure, a correlation between the values of P-wave and QT dispersions exists. These findings may have etiopathogenic, pathophysiologic, prognostic, and therapeutic implications, which should be investigated in other studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reconhecer com precisão indivíduos com maior risco imediato de morte súbita cardíaca (MSC) ainda é uma questão em aberto. A natureza fortuita dos eventos cardiovasculares agudos não parece se adequar ao conhecido modelo de indução de taquicardia/fibrilação ventricular por um gatilho em sincronia a um substrato arritmogênico estático. Quanto ao mecanismo da MSC, uma instabilidade elétrica dinâmica explicaria melhor a raridade da associação simultânea de um gatilho certo a um substrato cardíaco apropriado. Diversos estudos tentaram medir essa instabilidade elétrica cardíaca (ou um equivalente válido) em uma sequência de batimentos cardíacos no ECG. Dentre os mecanismos possíveis podemos citar o prolongamento do QT, dispersão do QT, potenciais tardios, alternância de onda T ou T-wave alternans (TWA), e turbulência da frequência cardíaca. Este artigo se atém em particular ao papel da TWA no panorama atual da estratificação de risco cardíaco. Os achados sobre TWA ainda são heterogêneos, variando de um desempenho prognóstico muito bom até um quase nulo, dependendo da população clínica observada e protocolo clínico usado. Para preencher as atuais lacunas no conhecimento sobre TWA, profissionais médicos e pesquisadores devem explorar melhor as características técnicas das diversas tecnologias disponíveis para a avaliação de TWA e atentar ao fato de que os valores de TWA respondem a diversos outros fatores, além de medicamentos. Informações sobre mecanismos celulares e subcelulares da TWA estão fora do escopo deste artigo, mas são referenciados alguns dos principais trabalhos sobre este tópico, com o intuito de auxiliar no entendimento dos conceitos e fatos cobertos neste artigo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La mort subite est la première cause de mortalité chez les patients souffrant d'une insuffisance rénale terminale traités par dialyse chronique. La technique de dialyse utilisée et la composition chimique du dialysat influencent l'incidence des arythmies. Des études pilotes démontrent que l'utilisation d'un dialysat sans acétate avec perfusion de bicarbonate de sodium en aval du filtre de dialyse, couplée à une modulation du profil de potassium pendant la séance de dialyse, ou acetate free biofiltration with potassium profiled dialysate, permet de réduire l'incidence des arythmies, l'intervalle QT et sa dispersion. La limitation du volume de soustraction liquidienne pendant la dialyse et l'augmentation de la concentration de calcium dans le dialysat constituent d'autres stratégies anti-arythmogènes possibles Sudden death is the first cause of mortality in patients with end stage renal disease undergoing chronic dialysis treatment. The technique of dialysis as well as the chemical composition of the dialysate can impact on the incidence of cardiac arrhythmias. Pilot studies reveal that the use of an acetate-free dialysate with a downstream filter infusion of sodium bicarbonate, coupled with a modulated potassium-profiled dialysate during hemodialysis, or acetate free biofiltration with potassium profiled dialysate, reduces the incidence of arrhythmias, the QT interval and QT dispersion. The limitation of the ultrafiltration volume during the dialysis session, and the increase in calcium concentration in the dialysate are other possible strategies to reduce cardiac arrhythmias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: La surcharge de pression ventriculaire augmente à l’exercice chez les patients avec une sténose de valve aortique (SVA). Lorsqu’il n’y a aucun symptôme apparent, il est cependant difficile d’indiquer l’intervention chirurgicale en utilisant seulement les indices de surcharge de pression ventriculaire. D’autres paramètres, tels que la dispersion de la repolarisation ventriculaire (d-QT), qui augmentent avec le gradient de pression transvalvulaire (GPT), n’ont pas été étudiés dans la SVA. L’objectif de l’étude était de déterminer le modèle de réponse du segment QT et de la d-QT à l’épreuve d’effort chez des enfants avec une SVA congénitale modérée afin d’évaluer l’impact de la surcharge de pression ventriculaire selon une perspective électrophysiologique. Matériel et méthodes: 15 patients SVA modérés ont été comparés à 15 sujets contrôles appariés pour l’âge (14.8±2.5 ans vs. 14.2±1.5 ans) et pour le sexe (66,7% de sujets mâles). Tous les sujets ont fait une épreuve d’effort avec enregistrement électrocardiographique à 12 dérivations. Le segment QT a été mesuré à partir du début du complexe QRS jusqu’à l’apex de l’onde T (QTa) au repos, à l’effort maximal ainsi qu’après 1 et 3 minutes de récupération. La longueur du segment QT a été corrigée selon l’équation de Fridericia et la d-QT a été calculée. Résultats: La longueur du segment QT corrigée (QTc) était similaire au repos entre les groupes d’étude, mais était significativement élevée chez les SVA en comparaison avec le groupe contrôle à l’effort maximal (p=0.004) ainsi qu’après 1 (p<0.001) et 3 (p<0.001) minutes de récupération. Une interaction significative a été identifiée entre les groupes pour la d-QT (p=0.034) et les tests post hoc ont révélé une différence significative seulement au repos (p=0.001). Conclusions: Les anomalies de repolarisation ventriculaire peuvent être révélées par l’évaluation de la repolarisation électrique lors de l’épreuve d’effort chez les SVA modérées asymptomatiques. L’utilisation de la réponse du QT à l’effort pourrait être bénéfique pour l’optimisation de la stratification du risque chez ces patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The controversial effects promoted by cardiac resynchronization therapy (CRT) on the ventricular repolarization (VR) have motivated VR evaluation by body surface potential mapping (BSPM) in CRT patients. Methods: Fifty-two CRT patients, mean age 58.8 +/- 12.3 years, 31 male, LVEF 27.5 +/- 9.2, NYHA III-IV heart failure with QRS181.5 +/- 14.2 ms, underwent 87-lead BSPM in sinus rhythm (BASELINE) and biventricular pacing (BIV). Measurements of mean and corrected QT intervals and dispersion, mean and corrected T peak end intervals and their dispersion, and JT intervals characterized global and regional (RV, Intermediate, and LV regions) ventricular repolarization response. Results: Global QTm (P < 0.001) and QTcm (P < 0.05) were decreased in BIV; QTm was similar across regions in both modes (P = ns); QTcm values were lower in RV/LV than in Intermediate region in BASELINE and BIV (P < 0.001); only RV/Septum showed a significant difference (P < 0.01) in the BIV mode. QTD values both of BASELINE (P < 0.01) and BIV (P < 0.001) were greater in the Intermediate than in the LV region. CRT effect significantly reduced global/regional QTm and QTcm values. QTD was globally decreased in RV/LV (Intermediate: P = ns). BIV mode significantly reduced global T peak end mean and corrected intervals and their dispersion. JT values were not significant. Conclusions: Ventricular repolarization parameters QTm, QTcm, and QTD global/regional values, as assessed by BSPM, were reduced in patients under CRT with severe HF and LBBB. Greater recovery impairment in the Intermediate region was detected by the smaller variation of its dispersion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sickle cell anemia (SCA) is associated to increased cardiac output, normal heart rate (HR), abnormal QT dispersion and lower diastolic blood pressure (DBP). The mechanisms are still unknown. The objective of this study was to test the hypothesis that there is cardiovascular autonomic dysfunction (CAD) in SCA. The secondary objectives were to distinguish the roles of chronic anemia and hemoglobinopathy and to evaluate the predominance of the sympathetic or parasympathetic systems in the pathogenesis of CAD. Sixteen subjects with SCA, 13 with sickle cell trait (SCT), 13 with iron deficiency anemia (IDA), and 13 healthy volunteers (HV) were evaluated. All subjects were submitted to 24 h-electrocardiogram (24 h-ECG), plasma norepinephrine (NE) measurement before and after isometric exercise (IE), and also Valsalva maneuver (VM), diving maneuver (DV), and tilt test (TT). Baroreflex sensitivity (BRS) was also evaluated. The minimum, average and maximum HR as well as the percentage of bradycardia and tachycardia at 24-h ECG were similar in all groups. NE at baseline and after IE did not differ between groups. The SCA group showed less bradycardia at phase IV of VM, less bradycardia during DV, and also less tachycardia and lower DBP during TT. BRS for bradycardia and tachycardia reflex was decreased in the SCA and SCT groups. In conclusion, 1) there is CAD in SCA, and it is characterized by the reduction of BRS and the limitation of HR modulation mediated by the parasympathetic system; 2) cardiovascular sympathetic activity is preserved in SCA; and 3) hemoglobinopathy is the preponderant ethiopathogenic factor. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To determine in arrhythmogenic right ventricular cardiomyopathy the value of QT interval dispersion for identifying the induction of sustained ventricular tachycardia in the electrophysiological study or the risk of sudden cardiac death. METHODS: We assessed QT interval dispersion in the 12-lead electrocardiogram of 26 patients with arrhythmogenic right ventricular cardiomyopathy. We analyzed its association with sustained ventricular tachycardia and sudden cardiac death, and in 16 controls similar in age and sex. RESULTS: (mean ± SD). QT interval dispersion: patients = 53.8±14.1ms; control group = 35.0±10.6ms, p=0.001. Patients with induction of ventricular tachycardia: 52.5±13.8ms; without induction of ventricular tachycardia: 57.5±12.8ms, p=0.420. In a mean follow-up period of 41±11 months, five sudden cardiac deaths occurred. QT interval dispersion in this group was 62.0±17.8, and in the others it was 51.9±12.8ms, p=0.852. Using a cutoff > or = 60ms to define an increase in the degree of the QT interval dispersion, we were able to identify patients at risk of sudden cardiac death with a sensitivity of 60%, a specificity of 57%, and positive and negative predictive values of 25% and 85%, respectively. CONCLUSION: Patients with arrhythmogenic right ventricular cardiomyopathy have a significant increase in the degree of QT interval dispersion when compared with the healthy population. However it, did not identify patients with induction of ventricular tachycardia in the electrophysiological study, showing a very low predictive value for defining the risk of sudden cardiac death in the population studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we discuss the use of photonic crystal fibers (PCFs) as discrete devices for simultaneous wideband dispersion compensation and Raman amplification. The performance of the PCFs in terms of gain, ripple, optical signal-to-noise ratio (OSNR) and required fiber length for complete dispersion compensation is compared with conventional dispersion compensating fibers (DCFs). The main goal is to determine the minimum PCF loss beyond which its performance surpasses a state-of-the-art DCF and justifies practical use in telecommunication systems. (C) 2009 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Leifsonia xyli is a xylem-inhabiting bacterial species comprised of two subspecies: L. xyli subsp. xyli (Lxx) and L. xyli subsp. cynodontis (Lxc). Lxx is the causal agent of ratoon stunting disease in sugarcane commercial fields and Lxc colonizes the xylem of several grasses causing either mild or no symptoms of disease. The completely sequenced genome of Lxx provided insights into its biology and pathogenicity. Since IS elements are largely reported as an important source of bacterial genome diversification and nothing is known about their role in chromosome architecture of L. xyli, a comparative analysis of Lxc and Lxx elements was performed. Results: Sample sequencing of Lxc genome and comparative analysis with Lxx complete DNA sequence revealed a variable number of IS transposable elements acting upon genomic diversity. A detailed characterization of Lxc IS elements and a comparative review with IS elements of Lxx are presented. Each genome showed a unique set of elements although related to same IS families when considering features such as similarity among transposases, inverted and direct repeats, and element size. Most of the Lxc and Lxx IS families assigned were reported to maintain transposition at low levels using translation regulatory mechanisms, consistent with our in silico analysis. Some of the IS elements were found associated with rearrangements and specific regions of each genome. Differences were also found in the effect of IS elements upon insertion, although none of the elements were preferentially associated with gene disruption. A survey of transposases among genomes of Actinobacteria showed no correlation between phylogenetic relatedness and distribution of IS families. By using Southern hybridization, we suggested that diversification of Lxc isolates is also mediated by insertion sequences in probably recent events. Conclusion: Collectively our data indicate that transposable elements are involved in genome diversification of Lxc and Lxx. The IS elements were probably acquired after the divergence of the two subspecies and are associated with genome organization and gene contents. In addition to enhancing understanding of IS element dynamics in general, these data will contribute to our ongoing comparative analyses aimed at understanding the biological differences of the Lxc and Lxx.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Discussion surrounding the settlement of the New World has recently gained momentum with advances in molecular biology, archaeology and bioanthropology. Recent evidence from these diverse fields is found to support different colonization scenarios. The currently available genetic evidence suggests a ""single migration'' model, in which both early and later Native American groups derive from one expansion event into the continent. In contrast, the pronounced anatomical differences between early and late Native American populations have led others to propose more complex scenarios, involving separate colonization events of the New World and a distinct origin for these groups. Methodology/Principal Findings: Using large samples of Early American crania, we: 1) calculated the rate of morphological differentiation between Early and Late American samples under three different time divergence assumptions, and compared our findings to the predicted morphological differentiation under neutral conditions in each case; and 2) further tested three dispersal scenarios for the colonization of the New World by comparing the morphological distances among early and late Amerindians, East Asians, Australo-Melanesians and early modern humans from Asia to geographical distances associated with each dispersion model. Results indicate that the assumption of a last shared common ancestor outside the continent better explains the observed morphological differences between early and late American groups. This result is corroborated by our finding that a model comprising two Asian waves of migration coming through Bering into the Americas fits the cranial anatomical evidence best, especially when the effects of diversifying selection to climate are taken into account. Conclusions: We conclude that the morphological diversity documented through time in the New World is best accounted for by a model postulating two waves of human expansion into the continent originating in East Asia and entering through Beringia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron paramagnetic resonance measurements of NiCl(2)-4SC(NH(2))(2) reveal the low-energy spin dispersion, including a magnetic-field interval in which the two-magnon continuum is within k(B)T of the ground state, allowing a continuum of excitations over a range of k states, rather than only the k=0 single-magnon excitations. This produces a novel Y shape in the frequency-field EPR spectrum measured at T >= 1.5 K. Since the interchain coupling J(perpendicular to)< k(B)T, this shape can be reproduced by a single S=1 antiferromagnetic Heisenberg chain with a strong easy-plane single-ion anisotropy. Importantly, the combination of experiment and modeling we report herein demonstrates a powerful approach to probing spin dispersion in a wide range of interacting magnetic systems without the stringent sample requirements and complications associated with inelastic scattering experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron spin precession about an external magnetic field was studied by Faraday rotation on an inhomogeneous ensemble of singly charged, self-assembled (In,Ga)As/GaAs quantum dots. From the data the dependence of electron g-factor on optical transition energy was derived. A comparison with literature reports shows that the electron g-factors are quite similar for quantum dots with very different geometrical parameters, and their change with transition energy is almost identical. (C) 2011 American Institute of Physics. [doi:10.1063/1.3588413]