981 resultados para Poly(methylene blue)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical behavior of poly(methylene blue) on different electrodes has been investigated by electrochemical quartz crystal microbalance and in situ spectrophotometric measurements coupled to cyclic voltammetry. Polymeric films were obtained potentiodynamically and the charge transport mechanism was analyzed. The electrochemical results show that polymer electroactivity depends not only on pH but also on the substrate. Charge compensation changes with both pH and the size of the anions showing a transition in the pH range of polymer pKa. It was demonstrated by spectroelectrochemical experiments that the electroactivity of the film depends on the radical/radical cation equilibrium. The potentials where the most electroactive species are formed have been determined. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the preparation, characterization, and use of poly (methylene blue) (PMB)-modified glassy carbon electrodes (GCE) (GCE-PMB) in the detection of the thiols L-cysteine (L-CySH) and N-acetyl cysteine (Acy), and the herbicide glyphosate (GLYP) in pH 5.3 aqueous solution. The polymer film prepared by electropolymerization showed different characteristics such as robustness, stability, and redox properties satisfactorily. The surface coverage concentration (Gamma) of PMB was found to be 7.90 x 10(-9) - mol cm(-2). Moreover, we observed strong adhesion of the polymer film to the electrode surface. The results using GCE-PMB as a sensor indicated that this modified electrode exhibited electrocatalytic activity toward the detection of thiols and glyphosate in 0.1 mol L-1 KO (pH 5.3). Meanwhile, strong adsorption of the analytes on the GCE-PMB electrodes was also observed. Otherwise, using a low concentration (1 x 10(-4) mol L-1) of L-cysteine and N-acetyl cysteine and 8.9 x 10(-6) mol L-1 of glyphosate, separately, it was possible to observe a well-defined electrochemical response, thus providing an opportunity to further understand the applicability of PMB as a sensor for amino acid-based molecules. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copper doped methylene blue sensitized poly(vinyl alcohol) (MBPVA)–acrylamide films were fabricated to improve the storage life of recorded gratings. The films were fabricated using gravity settling method and the copper chloride concentration was optimized as 3:18 10 3 mol/l for a dye concentration of 6:2 10 4 mol/l. The gratings recorded on the optimized film constitution could be stored for months with stable diffraction efficiency (24%) without any chemical or thermal fixing techniques. The resolution of the material is found to be unaffected with the addition of copper chloride.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copper doped methylene blue sensitized poly(vinyl alcohol) (MBPVA)–acrylamide films were fabricated to improve the storage life of recorded gratings. The films were fabricated using gravity settling method and the copper chloride concentration was optimized as 3:18 10 3 mol/l for a dye concentration of 6:2 10 4 mol/l. The gratings recorded on the optimized film constitution could be stored for months with stable diffraction efficiency (24%) without any chemical or thermal fixing techniques. The resolution of the material is found to be unaffected with the addition of copper chloride.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Significant results of our experimental investigations on the dependence of pH on real time transmission characteristics on recording media fabricated by doping PVC with complexed methylene blue are presented. The optimum pH value for faster bleaching was found to be 4×5. In typical applications, the illumination from one side, normal to the surface of this material, initiates a chemical sequence that records the incident light pattern in the polymer. Thus direct imaging can be successfully done on this sample. The recorded letters were very legible with good contrast and no scattering centres. Diffraction efficiency measurements were also carried out on this material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copper doped methylene blue sensitized poly(vinyl alcohol) (MBPVA)–acrylamide films were fabricated to improve the storage life of recorded gratings. The films were fabricated using gravity settling method and the copper chloride concentration was optimized as 3:18 10 3 mol/l for a dye concentration of 6:2 10 4 mol/l. The gratings recorded on the optimized film constitution could be stored for months with stable diffraction efficiency (24%) without any chemical or thermal fixing techniques. The resolution of the material is found to be unaffected with the addition of copper chloride.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Significant results of our experimental investigations on the dependence of pH on real time transmission characteristics on recording media fabricated by doping PVC with complexed methylene blue are presented. The optimum pH value for faster bleaching was found to be 4×5. In typical applications, the illumination from one side, normal to the surface of this material, initiates a chemical sequence that records the incident light pattern in the polymer. Thus direct imaging can be successfully done on this sample. The recorded letters were very legible with good contrast and no scattering centres. Diffraction efficiency measurements were also carried out on this material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Significant results of our experimental investigations on the dependence of pH on real time transmission characteristics on recording media fabricated by doping PVC with complexed methylene blue are presented. The optimum pH value for faster bleaching was found to be 4 . 5. In typical applications, the illumination from one side, normal to the surface of this material, initiates a chemical sequence that records the incident light pattern in the polymer. Thus direct imaging can be successfully done on this sample. The recorded letters were very legible with good contrast and no scattering centres. Diffraction efficiency measurements were also carried out on this material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dept.of Polymer Science and Rubber Technology,Cochin University of Science and Technology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of chromium doping on methylene blue sensitized Poly (vinyl alcohol)/Acrylamide was carried out by varying the ratios of Ammonium dichromate and methylene blue. In the case of films without ammonium dichromate, the diffraction efficiency was found to decrease on storage. On chromium doping the storage life was improved. Interestingly, a self-enhancement in efficiency was observed for a particular ratio of methylene blue and ammonium dichromate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: We sought to investigate the wound-healing process after photodynamic therapy (PDT) mediated by methylene blue dye (MB). Background Data: Few scientific studies show the PDT roles in wound healing. Materials and Methods: One hundred rats were given a circular wound on the back, inflicted with a 6-mm-diameter punch. The animals were divided into four groups: control (no treatment); dye (topical application of MB); laser (InGaAlP, 117.85 J/cm(2), 100 mW, 660 nm, single point); and PDT (topical application of MB followed by laser irradiation). After 1, 3, 5, 7, and 14 days, the cutaneous wounds were photographed and assessed with histopathologic examination by using light microscope. Changes seen in edema, necrosis, inflammation, granulation tissue, re-epithelialization, and number of young fibroblasts were semiquantitatively evaluated. The wound-area changes were measured with special software and submitted to statistical analysis. Results: The laser group demonstrated the smallest wound area at 14 days after the surgical procedure (p<0.01). Concerning complete re-epithelialization, the laser group showed it at 5-7 days after surgery, whereas the PDT and the other groups showed it at 14 days. Conclusions: Laser interaction with tissue is somehow changed when exposed to the MB. PDT mediated by MB was not prejudicial to wound healing, as no delay occurred compared with the control group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antimicrobial photodynamic treatment (PDT) is a promising method that can be used to control localized mycoses or kill fungi in the environment. A major objective of the current study was to compare the conidial photosensitization of two fungal species (Metarhizium anisopliae and Aspergillus nidulans) with methylene blue (MB) and toluidine blue (TBO) under different incubation and light conditions. Parameters examined were media, photosensitizer (PS) concentration and light source. PDT with MB and TBO resulted in an incomplete inactivation of the conidia of both fungal species. Conidial inactivation reached up to 99.7%, but none of the treatments was sufficient to achieve a 100% fungicidal effect using either MB or TBO. PDT delayed the germination of the surviving conidia. Washing the conidia to remove unbound PS before light exposure drastically reduced the photosensitization of A. nidulans. The reduction was much smaller in M. anisopliae conidia, indicating that the conidia of the two species interact differently with MB and TBO. Conidia of green and yellow M. anisopliae mutants were less affected by PDT than mutants with white and violet conidia. In contrast to what occurred in PBS, photosensitization of M. anisopliae and A. nidulans conidia was not observed when PDT was performed in potato dextrose media.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Acrylic cement has been used for years on orthopaedic surgeries, especially on knee arthroplasties, deserving special attention when added to antibiotics (for treatment of deep bone infections) or stains (to facilitate its removal). The present study was conducted in order to evaluate potential mechanical differences between the orthopaedic cement itself and when this is added to antibiotic and/or stains. Methods: Surgical bone cement Simplex@P Stryker, vancomycin and methylene blue were used, and the mixtures were submitted to physical and mechanical tests according the ABNT NBR ISO 5833 rule. The parameters studied here were: time for mass formation, intrusion capability, resistance to compression, resistance to flexion and maximum temperature reached by the mixtures. Results: The evaluated mixtures were approved as to mass formation, maximum temperature, intrusion capability and resistance to compression. Only the one containing pure cement was approved on the flexion essay. Conclusion: The addition of vancomycin and/or methylene blue to Surgical Simplex@P Stryker bone cement reduces its resistance to flexion, being unacceptable by the ABNT NBR ISO 5833 rule.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To evaluate the extent sensory and motor blocks produced by the epidural injection of different volumes of 0.25% bupivacaine (Bu) with methylene blue (MB), in dogs. Study design Prospective experimental trial. Animals Twenty healthy adult mongrel dogs, weighing 9.9 +/- 1.9 kg. Methods Dogs were randomly allocated into one of four groups that received 0.2, 0.4, 0.6 or 0.8 mL kg-1 of an epidural solution containing 0.25% Bu and MB. Sensory block was evaluated against time by pinching the tail, hind limb interdigital web, toenail bases and the skin over the vertebral dermatomes. Motor block was assessed by ataxia, hind limb weight-bearing ability and by loss of muscle tone of the tail and pelvic limbs. Data were collected at 2, 5, 10, 15 and 30 minutes after the end of epidural injection. After the final time point, dogs were euthanatized and laminectomies were conducted to expose the extent of the dural dye staining. Results The volumes 0.2, 0.4, 0.6 and 0.8 mL kg-1 of 0.25% Bu and MB blocked a mean of 5, 14.2, 20.2 and 21 dermatomes, respectively. The extent of the senory block increased up to a volume of 0.6 mL kg-1. Motor block was longer-lasting and more intense than sensory block. Complete dyeing of the spinal cord with MB was achieved in some dogs at 0.4 mL kg-1 and all dogs at 0.6 mL kg-1. Conclusions The volume of anesthetic injected into the epidural space plays an important role in the quality of the epidural anesthesia. At 0.25%, bupivacaine provided an efficient sensory block at 0.6 mL kg-1. Clinical relevance Relatively high volumes (0.6 mL kg-1) of 0.25%, BU and MB were needed to produce an effective sensory and motor block caudal to the umbilicus, but all spinal cord segments were reached by MB at this dose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Agência Financiadora - Fundação para a Ciência e Tecnologia - PTDC/CTM NAN/113021/2009