1000 resultados para Pluma de fase livre


Relevância:

100.00% 100.00%

Publicador:

Resumo:

High fuel consumption and its inadequate control in fuel stations caused the pollution of soil and aquifers. These consequences created more concern with the increased exploration of aquifers to supply the groundwater demand. The objective of this study was to evaluate the eficiency and efectiveness of the of pump and treat technique of the water applied to the Coastal Aquifer in the cleaning up of the plumes produced by the leaking of fuel in the gas station Auto Posto Baía do Sol Ltda. The gas station is located in São Sebastião, in the north coast of São Paulo State. In the case of Auto Posto Baía do Sol Ltda., the technique of pump and treat was eficient and the plume produced by the leakage was completely removed. However, the efectiveness of this technique was low due to the long time required for the complete operation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta tese trata da relação matemática entre as espessuras real e aparente em contaminações subterrâneas com gasolina e com gasolina e etanol. Foi testada a hipótese de que a relação entre as espessuras dos dois tipos de gasolinas pode ser descrita pela mesma relação matemática desde que esta relação incorpore as tensões interfaciais entre a água e a gasolina e gasolina e o ar que ocorrem no meio poroso. É proposta uma relação matemática hidrostática para o equilíbrio considerando o contato entre o poço de monitoramento e o meio poroso e a tensão interfacial responsável pelos efeitos capilares no meio poroso e a densidade dos fluidos. Os experimentos conduzidos em meio poroso e colunas acrílicas mostraram um ajuste estatisticamente melhor da equação matemática proposta para a gasolina pura e um ajuste que apresentou menor representatividade estatística para a gasolina com etanol. Esta discrepância está relacionada ao fato da transferência de massa do etanol presente na gasolina para a água não ser um fenômeno desprezível, causar grande influência no sistema e não estar contemplada na relação matemática proposta. Outro fenômeno observado em gotas de fluidos em experimentos para medir a tensão interfacial pode ser responsável pelo ajuste menos representativo da equação que é a presença de instabilidades na interface de contato entre a gasolina e a água. Estas instabilidades que são chamadas na literatura de Efeito Marangoni produzem variações na interface entre água e gasolina e são também responsáveis pela diferença no ajuste da equação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Previous studies show that in areas contaminated by fuel spill (NAPL- non-aqueous phase liquids), from operational activities, transport and storage, it was possible to observe a significant decrease of ²²²Rn (radon) gas concentration in the soil, even a non-uniform distribution of this gas in top soil, even with a geological situation was practically homogeneous. These anomalies may be associated with the preference partitioning of radon in NAPLs. This work consists of applying ²²²Rn as an indicator for locating subsurface contamination by NAPLs in an area of the city of Rio Claro (SP) where, according to the “Survey of Contaminated and Rehabilitated Areas in the State of São Paulo (Environmental Sanitation and Technology Company - CETESB), there was, in the year 2007, groundwater contamination from leaks of liquid fuels. The challenges of this research are: Promulgate the use of a new tool with greater efficiency in obtaining results, in addition to generate less impact in half and have less expenditure; disseminate scientific culture promoting greater integration of C&T (culture & technology) between universities and businesses. The emanometric technique to estimate the location, number and interfacial area of NAPL in saturated and non-saturated zone, has the advantage of locating and determining plumes of free phase even when the amount of VOC's (Volatile Organic Compounds) that reaches the surface is low or non-existent. In addition, the measurement techniques ²²²Rn are quite developed. The results obtained show that, similar to the other studies, the 222Rn soil gas presents an anomalous behavior in the area bounded by NAPL plume, being possible to note a significant deficit in the concentration of the gas in spots where the saturation by NAPLs is still critical. Therefore it is concluded that this tool is really promising, but we must be careful to evaluate the initial conditions of the area, as well as the type of...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Activities that have fuel subterranean storage system are considered potentially polluting fuels by CONAMA Resolution 273, due to the possibility of leak, outpouring and overflow of fuel into the ground. Being even more worrying when contaminate groundwater for public supply, as the case of Natal City. For this reason, the Public Ministry/RN, in partnership with UFRN, developed the project environmental suitability of Gas stations in Natal, of which 36% showed evidence of contamination. This paper describes the four stages of the management of contaminated areas: preliminary assessment of environmental liabilities, detailed confirmatory investigation of the contamination, risk analysis to human health (RBCA), as well as the remediation plan of degraded areas. Therefore it is presented a case study. For the area investigated has been proposed a mathematical method to estimate the volume of LNAPL by a free CAD software (ScketchUp) and compare it with the partition method for grid area. Were also performed 3D graphics designs of feathers contamination. Research results showed that passive benzene contamination in groundwater was 2791.77 μg/L, when the maximum allowed by CONAMA Resolution 420 is 5 μg/L which is the potability standards. The individual and cumulative risks were calculated from 4.4 x10-3, both above the limits of 1.0 x10-5 or by RBCA 1.0 x10-6 by the Public Ministry/RN. Corrective action points that remediation of dissolved phase benzene is expected to reach a concentration of 25 μg/L, based on carcinogenic risk for ingestion of groundwater by residents residential, diverging legislation. According to the proposed model, the volume of LNAPL using the ScketchUp was 17.59 m3, while by the grid partitioning method was 14.02 m3. Because of the low recovery, the expected removal of LNAPL is 11 years, if the multiphase extraction system installed in the enterprise is not optimized

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The geoelectrical methods have been widely used in research involving the evaluation and monitoring of areas with environmental risk. This paper presents the results of applying the Electrical Resistivity method by electrical profiling technique to investigate the fuel presence in soil and groundwater proceeding in station gas, located in an urban area Caçapava do Sul (RS), on soil in situ, from modification of Caçapava granite. The results suggest an association between low resistivity anomalies zone with potentially degraded from underground tanks worthless on the form of free phase, now represented as residual phase. The results of the model inversion are consistent with the standards expected for hydrocarbons present in the saturated zone. The electrical resistivity method proved to be an important tool for assessment and environmental monitoring in conjunction with direct methods of investigation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Activities that have fuel subterranean storage system are considered potentially polluting fuels by CONAMA Resolution 273, due to the possibility of leak, outpouring and overflow of fuel into the ground. Being even more worrying when contaminate groundwater for public supply, as the case of Natal City. For this reason, the Public Ministry/RN, in partnership with UFRN, developed the project environmental suitability of Gas stations in Natal, of which 36% showed evidence of contamination. This paper describes the four stages of the management of contaminated areas: preliminary assessment of environmental liabilities, detailed confirmatory investigation of the contamination, risk analysis to human health (RBCA), as well as the remediation plan of degraded areas. Therefore it is presented a case study. For the area investigated has been proposed a mathematical method to estimate the volume of LNAPL by a free CAD software (ScketchUp) and compare it with the partition method for grid area. Were also performed 3D graphics designs of feathers contamination. Research results showed that passive benzene contamination in groundwater was 2791.77 μg/L, when the maximum allowed by CONAMA Resolution 420 is 5 μg/L which is the potability standards. The individual and cumulative risks were calculated from 4.4 x10-3, both above the limits of 1.0 x10-5 or by RBCA 1.0 x10-6 by the Public Ministry/RN. Corrective action points that remediation of dissolved phase benzene is expected to reach a concentration of 25 μg/L, based on carcinogenic risk for ingestion of groundwater by residents residential, diverging legislation. According to the proposed model, the volume of LNAPL using the ScketchUp was 17.59 m3, while by the grid partitioning method was 14.02 m3. Because of the low recovery, the expected removal of LNAPL is 11 years, if the multiphase extraction system installed in the enterprise is not optimized

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Steady-State Free Precession (SSFP) sequence has been widely used in low-field and low-resolution imaging NMR experiments to increase the signal-to-noise ratio (s/n) of the signals. Here, we analyzed the Scrambled Steady State - SSS and Unscrambled Steady State - USS sequences to suppress phase anomalies and sidebands of the 13C NMR spectrum acquired in the SSFP regime. The results showed that the application of the USS sequence allowed a uniform distribution of the time interval between pulses (Tp), in the established time range, allowing a greater suppression of phase anomalies and sidebands, when compared with the SSS sequence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Steady-State Free Precession (SSFP) sequence has been widely used in low-field and low-resolution imaging NMR experiments to increase the signal-to-noise ratio (s/n) of the signals. Here, we analyzed the Scrambled Steady State - SSS and Unscrambled Steady State - USS sequences to suppress phase anomalies and sidebands of the 13C NMR spectrum acquired in the SSFP regime. The results showed that the application of the USS sequence allowed a uniform distribution of the time interval between pulses (Tp), in the established time range, allowing a greater suppression of phase anomalies and sidebands, when compared with the SSS sequence.