995 resultados para Platelet monoamine changes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study we assessed plasma and platelet monoamine content using high performance liquid chromatography (HPLC). The study included 22 subjects consisting of 12 freshly-detected male diabetic patients and 10 age and sex-matched healthy controls. The same parameters were measured in streptozotocin -induced diabetic rat models consisting of controls , diabetic and insulin - treated diabetic rats. The platelet counts were significantly reduced (P < 0.05) in rat models as well as human diabetic samples. The plasma norepinephrine (NE) and epinephrine (EPI) concentrations were significantly increased (P < 0.05). The platelet showed a significant increase (P < 0.01) in NE, EPI and serotonin content. Increase in the plasma and platelet content of neurotransmitters may be due to increased sympathetic function, which is an adaptation for the decreased platelet count observed in our study . The results indicate that changes in the neurotransmitter content of the platelet may be a good index to assess the neurotransmitter status in pathological condition such as diabetes mellitus.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it`s more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Variation in the personality trait of neuroticism is known to be affected by genetic influences, but despite a number of association studies, the genes involved have not yet been characterized. In a recent study of platelet monoamine oxidase in 1,551 twin subjects, we found a significant association between monoamine oxidase activity and scores on the Eysenck Personality Questionnaire neuroticism scale. Further analyses presented here indicate that both neuroticism and monoamine oxidase activity are associated with variation in smoking habits, and that adjusting for the effect of smoking strengthens the association between MAO and neuroticism. Analysis of the genetic and environmental sources of covariation between neuroticism, smoking, and monoamine oxidase activity show that approximately 8% of the genetic variance in neuroticism is due to the same additive genetic effects that contribute to variation in monoamine oxidase activity, suggesting that variation in neuroticism is associated in part with aspects of serotonin metabolism. (C) 2001 Wiley-Liss, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An increased or disturbed activation and aggregation of platelets plays a major role in the pathophysiology of thrombosis and haemostasis and is related to cardiovascular disease processes. In addition to qualitative disturbances of platelet function, changes in thrombopoiesis or an increased elimination of platelets, (e. g., in autoimmune thrombocytopenia), are also of major clinical relevance. Flow cytometry is increasingly used for the specific characterisation of phenotypic alterations of platelets which are related to cellular activation, haemostatic function and to maturation of precursor cells. These new techniques also allow the study of the in vitro response of platelets to stimuli and the modification thereof under platelet-targeted therapy as well as the characterisation of platelet-specific antibodies. In this protocol, specific flow cytometric techniques for platelet analysis are recommended based on a description of the current state of flow cytometric methodology. These recommendations are an attempt to promote the use of these new techniques which are at present broadly evaluated for diagnostic purposes. Furthermore, the definition of the still open questions primarily related to the technical details of the method should help to promote the multi-center evaluation of procedures with the goal to finally develop standardized operation procedures as the basis of interlaboratory reproducibility when applied to diagnostic testing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it's more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION To what extent haematocrit levels (Hct) and platelet counts (PLT) influence the measurement of parameters of thromboelastometry when assessed with the ROTEM® device is unclear. We investigated to what extent thromboelastometry measurements depend on Hct and PLT. MATERIALS AND METHODS Whole blood samples were taken for in-vitro preparations of mixtures with three different levels of PLT and a varying Hct. Maximum clot firmness (MCF), clotting time (CT), clot formation time (CFT) and alpha angle (α) for INTEM, EXTEM, FIBTEM and APTEM was recorded. RESULTS Measurements depended substantially on Hct and PLT. MCF readings were systematically lower with increasing Hct (0.2 vs. 0.4: -7.8 (-8.3 to -7.2); p<0.001, 0.2 vs. 0.55: -14.5 (-17.3 to -14.3); p<0.001) but higher with increasing PLT (50 vs. 125×10(9)/l: 8.2 (4.2 to 12.3); p=0.005, 50 vs. 250×10(9)/l: 12.0 (7.2 to 16.8); p=0.002). CT readings were systematically higher with increasing Hct (0.2 vs. 0.4: 9.2 (6.2 to 12.1); p=0.001, 0.2 vs. 0.55: 38.2 (21.5 to 54.9); p=0.003) while increasing PLT had no influence. CFT readings were also systematically higher with increasing Hct (0.2 vs. 0.4: 83.8 (40.2 to 127.6); p=0.006, 0.2 vs. 0.55: 226.2 (110.7 to 341.7); p=0.006) but systematically lower with increasing PLT (50 vs. 125×10(9)/l: -144.0 (-272.3 to -15.6); p=0.036, 50 vs. 250×10(9)/l: -189.2 (-330.4 to -48.0); p=0.02); readings of the alpha angle showed a similar pattern. CONCLUSIONS Our results suggest that readings of thromboelastometry parameters need to be adjusted by Hct and PLT to avoid potential confounding and miss-interpretations in clinical practice.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved. Funding The study was funded by TENOVUS Scotland (G12/14). Jan Jansen is in receipt of salary support through the NHS Research Scotland (NRS) fellowship scheme. Acknowledgements The authors are extremely grateful for the expert assistance and contributions of Dr Neil Scott (Medical Statistician, University of Aberdeen), Win Culley (Research Nurse, Woodend Hospital), Dr Karen Cranfield (Consultant Anaesthetist), and Ms Sharon Wood, (Research Technician, Rowett Institute of Nutrition and Health) for fibrinogen measurement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reported in vitro data implicated soluble CD40 ligand (sCD40L) in endothelial dysfunction and angiogenesis. However, whether sCD40L could exert that influence in endothelial dysfunction and angiogenesis after injury in acute myocardial infarction (AMI) patients remains unclear. In the present study, we evaluated the association of sCD40L with markers of platelet activation, endothelial, and vascular function during a recovery period early after AMI. To achieve this goal, the time changes of soluble, platelet-bound, and microparticle-bound CD40L levels over 1 month were assessed in AMI patients and correlated with endothelial nitric oxide synthase (eNOS) polymorphisms, vascular endothelial growth factor (VEGF) concentrations, and platelet expression of P-selectin (CD62P). The association of soluble form, platelet-bound, and microparticle-bound CD40L with CD62P expression on platelets, a marker of platelet activation, was also assessed to evaluate the role of CD40L in the thrombosis, whereas the association with eNOS and VEGF was to evaluate the role of CD40L in vascular dysfunction. This work shows for the first time that time changes of sCD40L over 1 month after myocardial infarct onset were associated with G894T eNOS polymorphism and with the VEGF concentrations, but not to the platelet CD62P expression. These results indicate that, in terms of AMI pathophysiology, the sCD40L cannot be consider just as being involved in thrombosis and inflammation but also as having a relevant role in vascular and endothelial dysfunction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chronic hepatitis C (CHC) is one of the most important causes of chronic liver disease in the world, potentially resulting in cirrhosis, hepatocellular carcinoma, and the need for liver transplantation. Liver biopsy is currently performed before therapy indication. Although, it is the golden standard there are many reasons to avoid or delay the procedure. APRI Score is an easy, low cost and practice alternative method which was described as an alternative for assessing structural changes in chronic hepatitis C (CHC). The rationale of this study was to observe the accuracy of APRI Score in comparison to liver biopsy in 400 patients divided into two groups of 200 carriers (Validation and Experimental groups respectively) selected at random or according to liver fibrosis staging (METAVIR). The ROC curves showed a concordance among these two methods of 92% and 88.5% when 1.05 was the cut off (F3 and F4), and 87% and 83%, on 0.75 cut offs (F2-F4). The discordance in advanced fibrosis staging (F3 and F4) was only 16 (8%) and 22 (11%) out of 200 patients in the experimental and validation groups, respectively. In 26 (13%) out of 200 patients in the experimental group and 34 (17%) out of 200 patients in the validation group, there was discordance between APRI Score and liver biopsy in moderate and advanced fibrosis (F2-F4). In conclusion APRI is a serological marker that has satisfactory sensitivity and specificity together with a high predictive value and it can be useful either in the absence of a biopsy or to reduce the frequency with which biopsies need to be carried out to monitor the evolution of chronic hepatitis C and the right moment for treatment indication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Mesenchymal stem cells (MSCs) have been considered for human regenerative therapy applications, and safe culture and expansion protocols are needed especially in the context of interspecies contamination. Human platelet lysate (PL) has been proposed as animal serum substitute during in vitro MSC expansion. In this work, a simplified and efficient method to obtain autologous PL to replace animal serum in cell culture applications is described. STUDY DESIGN AND METHODS: PL obtained by freezing and centrifugation procedures was tested as medium supplement for human adipose mesenchymal stem cell (hASC) culture. Differential proliferation, immunophenotypic changes, and differentiation under PL or fetal bovine serum (FBS) were assessed. RESULTS: In contrast to 10% FBS supplementation, cell population doubling time was significantly lower when hASCs were cultured with the same concentration of PL ( PL 22.9 +/- 1.5 hr vs. FBS 106.7 +/- 6.5 hr, t test, p < 0.05). Furthermore, hASCs maintained with 2.5% PL supplementation also showed satisfactory results. Immunophenotypic analysis revealed no differences between hASCs cultivated with PL or FBS supplementation and both cultures retained the potential to differentiate into adipose cells. These results demonstrate that autologous PL obtained from the same donor can be used as animal serum substitute in hASC culture. CONCLUSIONS: Taken together, evidence is provided that platelets provided by a single donor are sufficient to obtain PL for hASC propagation for clinical-scale applications mitigating the potential untoward side effects associated with the use of animal-derived reagents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Thrombocytopenia is a common complication in malaria patients. The relationship between abnormal platelet profile and clinical status in malaria patients is unclear. In low and unstable endemic regions where vivax malaria predominates, the hematologic profiles of malaria patients and their clinical utility are poorly understood. The aim of this study was to characterize the thrombograms of malaria patients from Colombia, where Plasmodium vivax infection is common, and to explore the relationship between thrombograms and clinical status. Methods Eight hundred sixty-two malaria patients were enrolled, including 533 (61.8%) patients infected with Plasmodium falciparum, 311 (36.1%) patients infected with Plasmodium vivax and 18 (2.1%) patients with mixed infections. Results The most frequently observed changes were low platelet count (PC) and high platelet distribution width (PDW), which were observed in 65% of patients; thrombocytopenia with <50,000 platelets/µL was identified in 11% of patients. Patients with complications had lower PC and plateletcrit (PT) and higher PDW values. A higher risk of thrombocytopenia was identified in patients with severe anemia, neurologic complications, pulmonary complications, liver dysfunction, renal impairment and severe hypoglycemia. The presence of thrombocytopenia (<150,000 platelets/µL) was associated with a higher probability of liver dysfunction. Conclusions Young age, longer duration of illness and higher parasitemia are associated with severe thrombocytopenia. Our study showed that thrombocytopenia is related to malaria complications, especially liver dysfunction. High PDW in patients with severe malaria may explain the mechanisms of thrombocytopenia that is common in this group of patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A first episode of depression after 65 years of age has long been associated with both severe macrovascular and small microvascular pathology. Among the three more frequent forms of depression in old age, post-stroke depression has been associated with an abrupt damage of cortical circuits involved in monoamine production and mood regulation. Late-onset depression (LOD) in the absence of stroke has been related to lacunes and white matter lesions that invade both the neocortex and subcortical nuclei. Recurrent late-life depression is thought to induce neuronal loss in the hippocampal formation and white matter lesions that affect limbic pathways. Despite an impressive number of magnetic resonance imaging (MRI) studies in this field, the presence of a causal relationship between structural changes in the human brain and LOD is still controversial. The present article provides a critical overview of the contribution of neuropathology in post-stroke, late-onset, and late-life recurrent depression. Recent autopsy findings challenge the role of stroke location in the occurrence of post-stroke depression by pointing to the deleterious effect of subcortical lacunes. Despite the lines of evidences supporting the association between MRI-assessed white matter changes and mood dysregulation, lacunes, periventricular and deep white matter demyelination are all unrelated to the occurrence of LOD. In the same line, neuropathological data show that early-onset depression is not associated with an acceleration of aging-related neurodegenerative changes in the human brain. However, they also provide data in favor of the neurotoxic theory of depression by showing that neuronal loss occurs in the hippocampus of chronically depressed patients. These three paradigms are discussed in the light of the complex relationships between psychosocial determinants and biological vulnerability in affective disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Platelet free cytosolic calcium (PFCC) was measured in 21 healthy volunteers before and after cigarette smoking or physical exercise. The aim was to investigate whether acute blood pressure changes and increases in circulating levels of catecholamines and vasopressin modify PFCC. PFCC was determined using the Quin-2 method. Following cigarette smoking, significant increases in blood pressure, heart rate, plasma epinephrine (35 +/- 18 pg/ml before versus 51 +/- 31 pg/ml after smoking, P less than 0.05, mean +/- s.d.) and vasopressin levels (0.8 +/- 0.3 pg/ml before and 4.2 +/- 4.1 pg/ml after smoking, P less than 0.001) were observed. However, despite these acute hormonal and hemodynamic changes, PFCC remained stable at 156 +/- 55 nmol/l prior to the study and 157 +/- 29 nmol/l and 156 +/- 38 nmol/l at 20 and 80 min post-smoking, respectively. Acute physical exercise led to an increase in heart rate and systolic blood pressure but to a decrease in diastolic pressure. Moreover, a marked increase in plasma norepinephrine levels was observed after exercise (213 +/- 71 pg/ml before versus 747 +/- 501 pg/ml after exercise, P +/- 0.001). Again, PFCC was stable at 185 +/- 56 nmol/l at baseline versus 188 +/- 51 nmol/l at 20 min and 155 +/- 26 nmol/l at 80 min after exercise. These results therefore demonstrate that PFCC is not influenced acutely either by blood pressure increases, or by elevations in circulating catecholamine and vasopressin concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: We investigated changes in biomarkers of liver disease in HIV-HCV-coinfected individuals during successful combination antiretroviral therapy (cART) compared to changes in biomarker levels during untreated HIV infection and to HIV-monoinfected individuals. METHODS: Non-invasive biomarkers of liver disease (hyaluronic acid [HYA], aspartate aminotransferase-to-platelet ratio index [APRI], Fibrosis-4 [FIB-4] index and cytokeratin-18 [CK-18]) were correlated with liver histology in 49 HIV-HCV-coinfected patients. Changes in biomarkers over time were then assessed longitudinally in HIV-HCV-coinfected patients during successful cART (n=58), during untreated HIV-infection (n=59), and in HIV-monoinfected individuals (n=17). The median follow-up time was 3.4 years on cART. All analyses were conducted before starting HCV treatment. RESULTS: Non-invasive biomarkers of liver disease correlated significantly with the histological METAVIR stage (P<0.002 for all comparisons). The mean ±sd area under the receiver operating characteristic (AUROC) curve values for advanced fibrosis (≥F3 METAVIR) for HYA, APRI, FIB-4 and CK-18 were 0.86 ±0.05, 0.84 ±0.08, 0.80 ±0.09 and 0.81 ±0.07, respectively. HYA, APRI and CK-18 levels were higher in HIV-HCV-coinfected compared to HIV-monoinfected patients (P<0.01). In the first year on cART, APRI and FIB-4 scores decreased (-35% and -33%, respectively; P=0.1), mainly due to the reversion of HIV-induced thrombocytopaenia, whereas HYA and CK-18 levels remained unchanged. During long-term cART, there were only small changes (<5%) in median biomarker levels. Median biomarker levels changed <3% during untreated HIV-infection. Overall, 3 patients died from end-stage liver disease, and 10 from other causes. CONCLUSIONS: Biomarkers of liver disease highly correlated with fibrosis in HIV-HCV-coinfected individuals and did not change significantly during successful cART. These findings suggest a slower than expected liver disease progression in many HIV-HCV-coinfected individuals, at least during successful cART.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is not known whether the addition of ezetimibe to statins adds cardiovascular protection beyond the expected changes in lipid levels. Subjects with coronary heart disease were treated with four consecutive 1-week courses of therapy (T) and evaluations. The courses were: T1, 100 mg aspirin alone; T2, 100 mg aspirin and 40 mg simvastatin/10 mg ezetimibe; T3, 40 mg simvastatin/10 mg ezetimibe, and 75 mg clopidogrel (300 mg initial loading dose); T4, 75 mg clopidogrel alone. Platelet aggregation was examined in whole blood. Endothelial microparticles (CD51), platelet microparticles (CD42/CD31), and endothelial progenitor cells (CD34/CD133; CDKDR/CD133, or CD34/KDR) were quantified by flow cytometry. Endothelial function was examined by flow-mediated dilation. Comparisons between therapies revealed differences in lipids (T2 and T3T1 and T4, P=0.001). Decreased platelet aggregation was observed after aspirin (arachidonic acid, T1platelet aggregation, the amount of circulating endothelial and platelet microparticles, or endothelial progenitor cells. Cardiovascular protection following therapy with simvastatin/ezetimibe seems restricted to lipid changes and improvement of endothelial function not affecting the release of microparticles, mobilization of endothelial progenitor cells or decreased platelet aggregation.