920 resultados para Physiological optics
Resumo:
"References" at end of some of the chapters.
Resumo:
"Edition limited to four hundred copies."
Resumo:
"A quarterly journal edited by Charles Sheard."
Resumo:
Earlier ed. published in 1872.
Resumo:
Includes bibliographies and indexes.
Resumo:
Purpose: To study the oculometric parameters of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods: Thirty-seven patients (5-8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett`s equations. Paired Student`s t-tests were used to compare ocular biometric measurements between amblyopic eyes and their fellow eyes. The associations of biometric parameters with refractive errors were assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results: Amblyopic eyes were found to have significantly more hyperopic refraction, less corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio (r(36) = -0.92, p < 0.001 for amblyopic and r(36) = 0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% (R(2)) of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. Adding corneal power to the model increased R(2) to 85.7% and 79.6%, respectively. A statistically significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes (r(36) = 0.53,p < 0.001) and fellow eyes (r(36) = -0.57, p < 0.001). A statistically significant correlation was also found between axial length and lens power, indicating decreasing lens power with increasing axial length (r(36) = -0.72, p < 0.001 for amblyopic eyes and r(36) = -0.69, p < 0.001 for fellow eyes). Conclusions: We observed that the correlation among the major oculometric parameters and their individual contribution to hyperopia in esotropic children were similar in amblyopic and non-amblyopic eyes. This finding suggests that the counterbalancing effect of greater corneal and lens power associated with shorter axial length is similar in both eyes of patients with esotropic amblyopia.
Resumo:
Purpose: Vergence and accommodation studies often use adult participants with experience of vision science. Reports of infant and clinical responses are generally more variable and of lower gain, with the implication that differences lie in immaturity or sub-optimal clinical characteristics but expert/naïve differences are rarely considered or quantified. Methods: Sixteen undergraduates, naïve to vision science, were individually matched by age, visual acuity, refractive error, heterophoria, stereoacuity and near point of accommodation to second- and third-year orthoptics and optometry undergraduates (‘experts’). Accommodation and vergence responses were assessed to targets moving between 33 cm, 50 cm, 1 m and 2 m using a haploscopic device incorporating a PlusoptiX SO4 autorefractor. Disparity, blur and looming cues were separately available or minimised in all combinations. Instruction set was minimal. Results: In all cases, vergence and accommodation response slopes (gain) were steeper and closer to 1.0 in the expert group (p = 0.001), with the largest expert/naïve differences for both vergence and accommodation being for near targets (p = 0.012). For vergence, the differences between expert and naïve response slopes increased with increasingly open-loop targets (linear trend p = 0.025). Although we predicted that proximal cues would drive additional response in the experts, the proximity-only cue was the only condition that showed no statistical effect of experience. Conclusions: Expert observers provide more accurate responses to near target demand than closely matched naïve observers. We suggest that attention, practice, voluntary and proprioceptive effects may enhance responses in experienced participants when compared to a more typical general population. Differences between adult reports and the developmental and clinical literature may partially reflect expert/naïve effects, as well as developmental change. If developmental and clinical studies are to be compared to adult normative data, uninstructed naïve adult data should be used.
Resumo:
A remote haploscopic photorefractor was used to assess objective binocular vergence and accommodation responses in 157 full-term healthy infants aged 1-6 months while fixating a brightly coloured target moving between fixation distances at 2, 1, 0.5 and 0.33 m. Vergence and accommodation response gain matured rapidly from 'flat' neonatal responses at an intercept of approximately 2 dioptres (D) for accommodation and 2.5 metre angles(MA) for vergence, reaching adult-like values at 4 months. Vergence gain was marginally higher in females (p = 0.064), but accommodation gain (p = 0.034) was higher and accommodative intercept closer to zero (p = 0.004) in males in the first 3 months as they relaxed accommodation more appropriately for distant targets. More females showed flat accommodation responses (p = 0.029). More males behaved hypermetropically in the first two months of life, but when these hypermetropic infants were excluded from the analysis, the gender difference remained. Gender differences disappeared after three months. Data showed variable responses and infants could behave appropriately and simultaneously on both, neither or only one measure at all ages. If accommodation was appropriate (gain between 0.7 and 1.3; r(2) > 0.7) but vergence was not, males over- and under-converged equally, while the females who accommodated appropriately were more likely to overconverge (p = 0.008). The apparent earlier maturity of the male accommodative responses may be due to refractive error differences but could also reflect gender-specific male preference for blur cues while females show earlier preference for disparity, which may underpin the earlier emerging, disparity dependent, stereopsis and full vergence found in females in other studies.
Resumo:
Purpose The relative efficiency of different eye exercise regimes is unclear, and in particular the influences of practice, placebo and the amount of effort required are rarely considered. This study measured conventional clinical measures after different regimes in typical young adults. Methods 156 asymptomatic young adults were directed to carry out eye exercises 3 times daily for two weeks. Exercises were directed at improving blur responses (accommodation), disparity responses (convergence), both in a naturalistic relationship, convergence in excess of accommodation, accommodation in excess of convergence, and a placebo regime. They were compared to two control groups, neither of which were given exercises, but the second of which were asked to make maximum effort during the second testing. Results Instruction set and participant effort were more effective than many exercises. Convergence exercises independent of accommodation were the most effective treatment, followed by accommodation exercises, and both regimes resulted in changes in both vergence and accommodation test responses. Exercises targeting convergence and accommodation working together were less effective than those where they were separated. Accommodation measures were prone to large instruction/effort effects and monocular accommodation facility was subject to large practice effects. Conclusions Separating convergence and accommodation exercises seemed more effective than exercising both systems concurrently and suggests that stimulation of accommodation and convergence may act in an additive fashion to aid responses. Instruction/effort effects are large and should be carefully controlled if claims for the efficacy of any exercise regime are to be made.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.
Resumo:
Stereoscopic depth perception utilizes the disparity cues between the images that fall on the retinae of the two eyes. The purpose of this study was to determine what role aging and optical blur play in stereoscopic disparity sensitivity for real depth stimuli. Forty-six volunteers were tested ranging in age from 15 to 60 years. Crossed and uncrossed disparity thresholds were measured using white light under conditions of best optical correction. The uncrossed disparity thresholds were also measured with optical blur (from +1.0D to +5.0D added to the best correction). Stereothresholds were measured using the Frisby Stereo Test, which utilizes a four-alternative forced-choice staircase procedure. The threshold disparities measured for young adults were frequently lower than 10 arcsec, a value considerably lower than the clinical estimates commonly obtained using Random Dot Stereograms (20 arcsec) or Titmus Fly Test (40 arcsec) tests. Contrary to previous reports, disparity thresholds increased between the ages of 31 and 45 years. This finding should be taken into account in clinical evaluation of visual function of older patients. Optical blur degrades visual acuity and stereoacuity similarly under white-light conditions, indicating that both functions are affected proportionally by optical defocus.
Resumo:
Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test.
Resumo:
Color vision was examined in subjects with long-term occupational exposure to mercury (Hg) vapor. The color vision impairment was assessed by employing a quantitative measure of distortion of individual and group perceptual color spaces. Hg subjects (n = 18; 42.1 +/- 6.5 years old; exposure time = 10.4 +/- 5.0 years; time away from the exposure source = 6.8 +/- 4.6 years) and controls (n = 18; 46.1 +/- 8.4 years old) were examined using two arrangement tests, D-15 and D-15d, in the traditional way, and also in a triadic procedure. From each subject`s `odd-one-out` choices, matrices of inter-cap subjective dissimilarities were derived and processed by non-metric multidimensional scaling (MDS). D-15d results differed significantly between the Hg-group and the control group (p < 0.05), with the impairment predominantly along the tritan axis. 2D perceptual color spaces, individual and group, were reconstructed, with the dimensions interpreted as the red-green (RG) and the blue-yellow (BY) systems. When color configurations from the Hg-group were compared to those of the controls, they presented more fluctuations along both chromatic dimensions, indicating a statistically significant difference along the BY axis. In conclusion, the present findings confirm that color vision impairments persist in subjects that have received long-term occupational exposure to Hg-vapor although, at the time of testing, they were presenting mean urinary concentration within the normal range for non-exposed individuals. Considering the advantages of the triadic procedure in clinical evaluation of acquired color vision deficiencies, further studies should attempt to verify and/or improve its efficacy.
Resumo:
Purpose: Most recently light and mobile reading devices with high display resolutions have become popular and they may open new possibilities for reading applications in education, business and the private sector. The ability to adapt font size may also open new reading opportunities for people with impaired or low vision. Based on their display technology two major groups of reading devices can be distinguished. One type, predominantly found in dedicated e-book readers, uses electronic paper also known as e-Ink. Other devices, mostly multifunction tablet-PCs, are equipped with backlit LCD displays. While it has long been accepted that reading on electronic displays is slow and associated with visual fatigue, this new generation is explicitly promoted for reading. Since research has shown that, compared to reading on electronic displays, reading on paper is faster and requires fewer fixations per line, one would expect differential effects when comparing reading behaviour on e-Ink and LCD. In the present study we therefore compared experimentally how these two display types are suited for reading over an extended period of time. Methods: Participants read for several hours on either e-Ink or LCD, and different measures of reading behaviour and visual strain were regularly recorded. These dependent measures included subjective (visual) fatigue, a letter search task, reading speed, oculomotor behaviour and the pupillary light reflex. Results: Results suggested that reading on the two display types is very similar in terms of both subjective and objective measures. Conclusions: It is not the technology itself, but rather the image quality that seems crucial for reading. Compared to the visual display units used in the previous few decades, these more recent electronic displays allow for good and comfortable reading, even for extended periods of time.