970 resultados para PULMONARY PERFUSION


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Visualization of the complex lung microvasculature and resolution of its three-dimensional architecture remains a difficult experimental challenge. We present a novel fluorescent microscopy technique to visualize both the normal and diseased pulmonary microvasculature. Physiologically relevant pulmonary perfusion conditions were applied using a low-viscosity perfusate infused under continuous airway ventilation. Intensely fluorescent polystyrene microspheres, confined to the vascular space, were imaged through confocal optical sectioning of 200 microm-thick lung sections. We applied this technique to rat lungs and the markedly enhanced depth of field in projected images allowed us to follow vascular branching patterns in both normal lungs and lungs from animals with experimentally induced pulmonary arterial hypertension. In addition, this method allowed complementary immunostaining and identification of cellular components surrounding the blood vessels. Fluorescent microangiography is a widely applicable and quantitative tool for the study of vascular changes in animal models of pulmonary disease.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

La perfusione polmonare extracorporea (EVLP) è una tecnica utilizzata dal 2010 per valutare e migliorare la qualità dell'organo da trapiantare e il danno da ischemia-ripefusione (IRI). Tale perfusione utilizza la soluzione di Steen, la cui composizione è solo parzialmente nota. Lo scopo è quello di identificare gli effetti di T3 su IRI polmonare ex vivo, in un modello di ratto di donatore a cuore non battente. Animali (40) randomizzati in otto gruppi e il protocollo EVLP sono stati standardizzati nel nostro centro. Sono state valutate la funzione polmonare, PEEP, la resistenza vascolare polmonare totale a 45, 60, 120 e 180 minuti di EVLP per eseguire analisi di gas, dosaggio del mediatore di infiammazione, mitocondriale libero DNA, freeT3 e freeT4. Alla fine dei campioni di tessuto polmonare sono stati congelati dal dosaggio ATP, espressione genica, DNA mitocondriale, T3. Non date le concentrazioni del produttore, abbiamo analizzato gli acidi grassi liberi, vitamine, ormoni e composizione della soluzione Steen. Risultati La soluzione di steen contiene albumina umana x2 nel siero umano (7,5-8 g/dl): le concentrazioni di ft4 e ft3 sono x2 quelle nel siero umano e vengono rilasciati dall'albumina. La concentrazione di ft4 e ft3 non è cambiata durante l'EVLP. La Steen ha alta fluorescenza per l'alta concentrazione delle molecole aromatiche (ormoni) mai descritto in precedenza. NADH e mtDNA nel perfused aumenta con danno ischemico e nel gruppo trattato con T3 Conclusione Il modello EVLP è già convalidato nella perfusione nel trapianto polmonare, ma è necessario approfondire l'effetto della Steen in termini di ormoni e analiti. L'effetto sull'IRI dell'EVLP sembra essere influenzato negativamente da un T3 troppo alto in Steen, cosa che descriviamo per la prima volta. L'ulteriore aggiunta di T3 provoca disfunzione mitocondriale e infiammazione.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A avaliação da função pulmonar em cães pode ser obtida mediante exames cintilográficos, os quais incluem a injeção de radiofármacos, seguida de radiografias. Neste estudo, foram utilizados 10 cães machos hígidos da raça Rottweiler e radiograficamente normais e soronegativos para dirofilariose, com administração de doses variadas de macroagregado de albumina sérica humana marcados com tecnécio-99m ([99mTc](MAA)). Os resultados foram avaliados qualitativa e quantitativamente, considerando o índice de perfusão pulmonar e sua homogeneidade, sendo dessa maneira visualizado um aumento na homogeneidade da imagem diretamente relacionado ao número de partículas de MAA injetado. Este estudo define os critérios de normalidade e de dosagem na perfusão pulmonar em cães hígidos da raça Rottweiller estabelecidos com a técnica de cintilografia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To compare immediate and late results in patients with or without fenestration who underwent cavopulmonary anastomosis so that we could assess the efficiency of the technique. METHODS: Sixty-two patients underwent surgery between 1988 and 1999, 41 with fenestration (group I -G I) and 21 without fenestration (group II -G II). Tricuspid atresia was prevalent in group I (23-56%) and single ventricle was prevalent in group II (14-66%). Mean ages at the time of operation were 7.3 years in group I and 7.6 in group II. At late follow-up, mean ages were 10.6 years in group I and 12.8 years in group II. RESULTS: Immediate and late mortality were 7.3% in G-I and 4.7% in G-II. Significant pleural effusion occurred in 41.4% of G-I patients and in 23.8% of G-II patients. Significant pericardial effusion occurred in 29.2% and 14.2%, respectively, in groups I and II. Central venous pressure was greater in G-II, 17.7 cm in H2O, as opposed to 15 cm in G-I. Hospital stay was similar between the groups, 26.3 and 21.8 days, respectively. Cyanosis and arterial insaturation occurred in 5 patients, and 4 patients were in functional class II, all from G-I. At late follow-up, 58 (93.5%) were in functional class I. Sinus rhythm was present in 94%, and pulmonary perfusion was similar in both groups. Eleven patients who underwent spirometry had good tolerance to physical effort. CONCLUSION: Atrial fenestration did not improve the immediate or late follow-up of patients who underwent cavopulmonary anastomosis, and is, therefore, dispensable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Breathing moves volumes of electrically insulating air into and out of the lungs, producing conductivity changes which can be seen by electrical impedance tomography (EIT). It has thus been apparent, since the early days of EIT research, that imaging of ventilation could become a key clinical application of EIT. In this paper, we review the current state and future prospects for lung EIT, by a synthesis of the presentations of the authors at the 'special lung sessions' of the annual biomedical EIT conferences in 2009-2011. We argue that lung EIT research has arrived at an important transition. It is now clear that valid and reproducible physiological information is available from EIT lung images. We must now ask the question: How can these data be used to help improve patient outcomes? To answer this question, we develop a classification of possible clinical scenarios in which EIT could play an important role, and we identify clinical and experimental research programmes and engineering developments required to turn EIT into a clinically useful tool for lung monitoring.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: In the last years cardiac surgery for congenital heart disease (CHD) reduced dramatically mortality modifying prognosis, but, at the same time, increased morbidity in this patient population. Respiratory and cardiovascular systems are strictly anatomically and functionally connected, so that alterations of pulmonary hemodynamic conditions modify respiratory function. While very short-term alterations of respiratory mechanics after surgery were investigated by many authors, not as much works focused on long-term changes. In these subjects rest respiratory function may be limited by several factor: CHD itself (fetal pulmonary perfusion influences vascular and alveolar development), extracorporeal circulation (CEC), thoracotomy and/or sternotomy, rib and sternal contusions, pleural adhesions and pleural fibrosis, secondary to surgical injury. Moreover inflammatory cascade, triggered by CEC, can cause endothelial damage and compromise gas exchange. Aims: The project was conceived to 1) determine severity of respiratory functional impairement in different CHD undergone to surgical correction/palliation; 2) identify the most and the least CHD involved by pulmonary impairement; 3) find a correlation between a specific hemodynamic condition and functional anomaly, and 4) between rest respiratory function and cardiopulmonary exercise test. Materials and methods: We studied 113 subjects with CHD undergone to surgery, and distinguished by group in accord to pulmonary blood flow (group 0: 28 pts with normal pulmonary flow; group 1: 22 pts with increased flow; group 2: 43 pts with decreased flow; group 3: 20 pts with total cavo-pulmonary anastomosis-TCPC) followed by the Pediatric Cardiology and Cardiac Surgery Unit, and we compare them to 37 age- and sex-matched healthy subjects. In Pediatric Pulmonology Unit all pts performed respiratory function tests (static and dynamic volumes, flow/volume curve, airway resistances-raw- and conductance-gaw-, lung diffusion of CO-DLCO- and DLCO/alveolar volume), and CHD pts the same day had cardiopulmonary test. They all were examined and had allergological tests, and respiratory medical history. Results: restrictive pattern (measured on total lung capacity-TLC- and vital capacity-VC) was in all CHD groups, and up to 45% in group 2 and 3. Comparing all groups, we found a significant difference in TLC between healthy and group 2 (p=0.001) and 3 (p=0.004), and in VC between group 2 and healthy (p=0.001) and group 1(p=0.034). Inspiratory capacity (IC) was decreased in group 2 related to healthy (p<0.001) and group 1 (p=0.037). We showed a direct correlation between TLC and VC with age at surgery (p=0.01) and inverse with number of surgical interventions (p=0.03). Reduced FEV1/FVC ratio, Gaw and increased Raw were mostly present in group 3. DLCO was impaired in all groups, but up to 80% in group 3 and 50% in group 2; when corrected for alveolar volume (DLCO/VA) reduction persisted in group 3 (20%), 2 (6.2%) and 0 (7.1%). Exercise test was impaired in all groups: VO2max and VE markedly reduced in all but especially in group 3, and VE/VCO2 slope, marker of ventilatory response to exercise, is increased (<36) in 62.5% of group 3, where other pts had anyway value>32. Comparing group 3 and 2, the most involved categories, we found difference in VO2max and VE/VCO2 slope (respectively p=0.02 and p<0.0001). We evidenced correlation between rest and exercise tests, especially in group 0 (between VO2max and FVC, FEV1, VC, IC; inverse relation between VE/VCO2slope and FVC, FEV1 and VC), but also in group 1 (VO2max and IC), group 2 (VO2max and FVC and FEV1); never in group 3. Discussion: According with literature, we found a frequent impairment of rest pulmonary function in all groups, but especially in group 2 and 3. Restrictive pattern was the most frequent alteration probably due to compromised pulmonary (vascular and alveolar) development secondary to hypoperfusion in fetal and pre-surgery (and pre-TCPC)life. Parenchymal fibrosis, pleural adhesions and thoracic deformities can add further limitation, as showed by the correlation between group 3 and number of surgical intervention. Exercise tests were limited, particularly in group 3 (complex anatomy and lost of chronotropic response), and we found correlations between rest and exercise tests in all but group 3. We speculate that in this patients hemodynamic exceeds respiratory contribution, though markedly decreased.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die regionale Bestimmung der Durchblutung (Perfusion) ermöglicht differenzierte Aussagen über den Gesundheitszustand und die Funktionalität der Lunge. Durch neue Messverfahren ermöglicht die Magnetresonanztomographie (MRT) eine nicht-invasive und strahlungsfreie Untersuchung der Perfusion. Obwohl die Machbarkeit qualitativer MRT-Durchblutungsmessungen bereits gezeigt wurde, fehlt bisher eine validierte quantitative Methode. Ziel dieser Arbeit war eine Optimierung der bestehenden Messprotokolle und mathematischen Modelle zur Absolutquantifizierung der Lungenperfusion mit Magnetresonanztomographie. Weiterhin sollte die Methodik durch Vergleich mit einem etablierten Referenzverfahren validiert werden. Durch Simulationen und Phantommessungen konnten optimale MRT-Messparameter und ein standardisiertes Protokoll festgelegt werden. Des Weiteren wurde eine verallgemeinerte Bestimmung der Kontrastmittelkonzentration aus den gemessenen Signalintensitäten vorgestellt, diskutiert und durch Probandenmessungen validiert. Auf der Basis dieser Entwicklungen wurde die MRT-Durchblutungsmessung der Lunge tierexperimentell mit der Positronenemissionstomographie (PET) intraindividuell verglichen und validiert. Die Ergebnisse zeigten nur kleine Abweichungen und eine statistisch hochsignifikante, stark lineare Korrelation. Zusammenfassend war es durch die Entwicklungen der vorgestellten Arbeit möglich, die kontrastmittelgestützte MRT-Durchblutungsmessung der Lunge zu optimieren und erstmals zu validieren.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT Varying pulmonary shunt fractions during the respiratory cycle cause oxygen oscillations during mechanical ventilation. In artificially damaged lungs, cyclical recruitment of atelectasis is responsible for varying shunt according to published evidence. We introduce a complimentary hypothesis that cyclically varying shunt in healthy lungs is caused by cyclical redistribution of pulmonary perfusion. Administration of crystalloid or colloid infusions would decrease oxygen oscillations if our hypothesis was right. Therefore, n = 14 mechanically ventilated healthy pigs were investigated in 2 groups: crystalloid (fluid) versus no-fluid administration. Additional volume interventions (colloid infusion, blood withdrawal) were carried out in each pig. Intra-aortal PaO(2) oscillations were recorded using fluorescence quenching technique. Phase shift of oxygen oscillations during altered inspiratory to expiratory (I:E) ventilation ratio and electrical impedance tomography (EIT) served as control methods to exclude that recruitment of atelectasis is responsible for oxygen oscillations. In hypovolemia relevant oxygen oscillations could be recorded. Fluid and volume state changed PaO(2) oscillations according to our hypothesis. Fluid administration led to a mean decline of 105.3 mmHg of the PaO(2) oscillations amplitude (P < 0.001). The difference of the amplitudes between colloid administration and blood withdrawal was 62.4 mmHg in pigs not having received fluids (P = 0.0059). Fluid and volume state also changed the oscillation phase during altered I:E ratio. EIT excluded changes of regional ventilation (i.e., recruitment of atelectasis) to be responsible for these oscillations. In healthy pigs, cyclical redistribution of pulmonary perfusion can explain the size of respiratory-dependent PaO(2) oscillations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent treatment planning studies have demonstrated the use of physiologic images in radiation therapy treatment planning to identify regions for functional avoidance. This image-guided radiotherapy (IGRT) strategy may reduce the injury and/or functional loss following thoracic radiotherapy. 4D computed tomography (CT), developed for radiotherapy treatment planning, is a relatively new imaging technique that allows the acquisition of a time-varying sequence of 3D CT images of the patient's lungs through the respiratory cycle. Guerrero et al. developed a method to calculate ventilation imaging from 4D CT, which is potentially better suited and more broadly available for IGRT than the current standard imaging methods. The key to extracting function information from 4D CT is the construction of a volumetric deformation field that accurately tracks the motion of the patient's lungs during the respiratory cycle. The spatial accuracy of the displacement field directly impacts the ventilation images; higher spatial registration accuracy will result in less ventilation image artifacts and physiologic inaccuracies. Presently, a consistent methodology for spatial accuracy evaluation of the DIR transformation is lacking. Evaluation of the 4D CT-derived ventilation images will be performed to assess correlation with global measurements of lung ventilation, as well as regional correlation of the distribution of ventilation with the current clinical standard SPECT. This requires a novel framework for both the detailed assessment of an image registration algorithm's performance characteristics as well as quality assurance for spatial accuracy assessment in routine application. Finally, we hypothesize that hypo-ventilated regions, identified on 4D CT ventilation images, will correlate with hypo-perfused regions in lung cancer patients who have obstructive lesions. A prospective imaging trial of patients with locally advanced non-small-cell lung cancer will allow this hypothesis to be tested. These advances are intended to contribute to the validation and clinical implementation of CT-based ventilation imaging in prospective clinical trials, in which the impact of this imaging method on patient outcomes may be tested.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction. Lung tranplantation, a consolidated treatment for end-stage lung disease, utilizes preservation solutions, such as low potassium dextran (LPD), to mitigate ischemia reperfusion injury. We sought the local development of LPD solutions in an attempt to facilitate access and enhance usage. We also sought to evaluate the effectiveness of a locally manufactured LPD solution in a rat model of ex vivo lung perfusion. Methods. We randomized the following groups \?\adult of male Wistar rats (n = 25 each): Perfadex (LPD; Vitro life, Sweden); locally manufactured LPD-glucose (LPDnac) (Farmoterapica, Brazil), and normal saline solution (SAL) with 3 ischemic times (6, 12, and 24 hours). The harvested heart lung blocks were flushed with solution at 4 C. After storage, the blocks were connected to an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus) and reperfused with homologous blood for 60 minutes. Respiratory mechanics, pulmonary artery pressure, perfusate blood gas analysis, and lung weight were measured at 10-minute intervals. Comparisons between groups and among ischemic times were performed using analysis of variance with a 5% level of significance. Results. Lungs preserved for 24 hours were nonviable and therefore excluded from the analysis. Those preserved for 6 hours showed better ventilatory mechanics when compared with 12 hours. The oxygenation capacity was not different between lungs flushed with LPD or LPDnac, regardless of the ischemic time. SAL lungs showed higher PCO(2) values than the other solutions. Lung weight increased over time during perfusion; however, there were no significant differences among the tested solutions (LPD, P = .23; LPDnac, P = .41; SAL, P = .26). We concluded that the LPDnac solution results in gas exchange were comparable to the original LPD (Perfadex); however ventilatory mechanics and edema formation were better with LPD, particularly among lungs undergoing 6 hours of cold ischemia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lung recruitment maneuvers (RMs), used to reopen atelectatic lung units and to improve oxygenation during mechanical ventilation, may result in hemodynamic impairment. We hypothesize that pulmonary arterial hypertension aggravates the consequences of RMs in the splanchnic circulation. Twelve anesthetized pigs underwent laparotomy and prolonged postoperative ventilation. Systemic, regional, and organ blood flows were monitored. After 6 h (= baseline), a recruitment maneuver was performed with sustained inflation of the lungs. Thereafter, the pigs were randomly assigned to group C (control, n = 6) or group E with endotoxin-induced pulmonary arterial hypertension (n = 6). Endotoxemia resulted in a normotensive and hyperdynamic state and a deterioration of the oxygenation index by 33%. The RM was then repeated in both groups. Pulmonary artery pressure increased during lipopolysaccharide infusion from 17 ± 2 mmHg (mean ± SD) to 31 ± 10 mmHg and remained unchanged in controls (P < 0.05). During endotoxemia, RM decreased aortic pulse pressure from 37 ± 14 mmHg to 27 ± 13 mmHg (mean ± SD, P = 0.024). The blood flows of the renal artery, hepatic artery, celiac trunk, superior mesenteric artery, and portal vein decreased to 71% ± 21%, 69% ± 20%, 76% ± 16%, 79% ± 18%, and 81% ± 12%, respectively, of baseline flows before RM (P < 0.05 all). Organ perfusion of kidney cortex, kidney medulla, liver, and jejunal mucosa in group E decreased to 65% ± 19%, 77% ± 13%, 66% ± 26%, and 71% ± 12%, respectively, of baseline flows (P < 0.05 all). The corresponding recovery to at least 90% of baseline regional blood flow and organ perfusion lasted 1 to 5 min. Importantly, the decreases in regional blood flows and organ perfusion and the time to recovery of these flows did not differ from the controls. In conclusion, lipopolysaccharide-induced pulmonary arterial hypertension does not aggravate the RM-induced significant but short-lasting decreases in systemic, regional, and organ blood flows.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

UNLABELLED The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. PATIENTS, MATERIAL AND METHODS 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. RESULTS Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. CONCLUSIONS SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. MATERIALS AND METHODS Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. RESULTS Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. CONCLUSION AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.