840 resultados para PROSTHESIS FAILURE
Resumo:
Patients with congenital malformations, traumatic or pathological mutilation and maxillofacial developmental disorders can be restored aesthetically and emotionally by the production and use of facial prostheses. The aim of this study was to review the literature about the retention and processing methods of facial prostheses, and discuss their characteristics. A literature review on Medline (PubMed) database was performed by using the keywords maxillofacial prosthesis, silicone, resin, pigment, cosmetic, prosthetic nose, based on articles published from 1956 to 2010. Several methods of retention, from adhesives to the placement of implants, and different processing methods such as laser, CAD/CAM and rapid prototyping technologies have been reported. There are advantages and disadvantages of each procedure, and none can be classified as better compared to others.
Resumo:
INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.
Resumo:
A 2-kilogram child had a pacemaker implanted by a subxyphoid approach with the generator located under the rectus sheath. Days later, the battery eroded the abdominal wall and the peritoneum. The whole system was removed and a new one was implanted inside the pericardium on an emergent basis.
Resumo:
To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods.
Resumo:
This study is a long-term analysis of a group of patients with infected arthroplasties of the hip or the knee. We identified 28 patients with an infected arthroplasty (22 hips, 6 knees) documented by bacterial culture or on direct examination. At the time of diagnosis and on follow-up (a mean of 46 months after treatment) we evaluated the clinical picture, the radiological appearances of the articulation and the biological parameters. 19/28 patients showed a typical clinical picture, whereas in 9 others the picture was more doubtful. The treatments were 14 two-stage replacements of the arthroplasties, 7 simple resections, 5 conservative treatments and 2 one-stage replacements. On follow-up, 25 patients were considered as cured of their infection and 3 as failures. From a functional viewpoint, 9 patients showed no limitation, whereas 19 were limited in the daily activity. Half of the patients had no pain. Radiology showed that 20/26 evaluated patients had no signs of recurrence. Paraclinical examinations are important in the diagnosis of persistent low grade infections, particularly the demonstration of bacteria by pre-surgical sampling (fine needle aspiration, culture from draining sinuses). In spite of the cure of infection, the functional and painful sequellae are often considerable. As a result of our experience, we recommend a two-stage surgical procedure. Only when the general condition of the patient is poor, or when the infection is not under control, would we envisage an alternative procedure (arthrodesis, girdelstone, conservative).
Resumo:
Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.
Resumo:
HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.
Resumo:
IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.
Resumo:
The transapical transcatheter aortic valve implantation (TA-TAVI) in degenerated aortic bioprosthesis is an emerging therapy for surgically non-amenable patients. However, the presence of different types of aortic bioprostheses (stented and stentless), available in different sizes (19-27 mm), can be at the origin of important mismatches between the malfunctioning, degenerated aortic valves and the inner stent-valves implanted through transapical accesses (23 and 26 mm Edwards Sapien transcatheter stent-valves). We report an emergency TA-TAVI treatment of a severely regurgitant degenerated 23 mm Mitroflow aortic bioprosthesis (Sorin Group, Milano, Italy) implanted seven years earlier in an 80-year-old lady, and we reviewed the current available literature about transapical 'valve-in-valve' procedures to analyze the hemodynamic results and the ideal 'prosthesis-to-prosthesis' match.
Resumo:
PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.
Resumo:
We conducted this study to determine the relative influence of various mechanical and patient-related factors on the incidence of dislocation after primary total hip asthroplasty (THA). Of 2,023 THAs, 21 patients who had at least 1 dislocation were compared with a control group of 21 patients without dislocation, matched for age, gender, pathology, and year of surgery. Implant positioning, seniority of the surgeon, American Society of Anesthesiologists (ASA) score, and diminished motor coordination were recorded. Data analysis included univariate and multivariate methods. The dislocation risk was 6.9 times higher if total anteversion was not between 40 degrees and 60 degrees and 10 times higher in patients with high ASA scores. Surgeons should pay attention to total anteversion (cup and stem) of THA. The ASA score should be part of the preoperative assessment of the dislocation risk.
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)