927 resultados para PH electrodes


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paperwork presents the complete circuitry used to build a microcontroller-based pH-meter. Key control software is also discussed. An industry-standard glass combination electrode has been employed for pH detection. Electrode parameter extraction procedure is presented. Good measurement results, with 1 % error, have been attained. Copyright© (2006) by the International Measurement Federation (IMEKO).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe a method for multiple indicator dilution studies in the isolated perfused human placental lobule developed to investigate the relationships between changes in pressure and flow and solute clearance. A peripheral lobule of a human placenta is perfused with a tissue culture-based medium and the perfusate oxygen tension, arterial and venous pressures, pH and perfusion temperature continuously monitored by a computerized system. Flow rates are readily changed. Bolus injections of vascular, extracellular and water space markers, and study compounds can be made into either maternal or fetal circulations, and precisely timed outflow fractions can be collected with computer-controlled fraction collectors, allowing simultaneous determination of concentration-time profiles of each marker. (C) 1997 Elsevier Science Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work gives a reader basic knowledge about mineralogy and mineral processing. Main focus of this work was on flotation process and pulp electrochemistry on flotation. Three different sulphide poor ores are examined on experimental part. Platinum and palladium were the noble metals, which were contained into studied ores. Electrochemistry of flotation of PGE minerals on sulphide poor ores has been examined only slightly. Bench scale flotation test was used in this study. Chalcopyrite, nickel-pentlandite, pyrite, platinum and pH electrodes were used to investigation of pulp electrochemistry during flotation tests. Effects of grinding media, carbon dioxide atmosphere in grinding and mixture of carbon dioxide and air as flotation gas to PGE flotation and electrochemistry of flotation were studied. Stainless steel grinding media created more oxidising pulp environment to flotation than mild steel grinding media. Concentrate quality improved also with stainless steel grinding media, but the recovery was remarkably poorer, than with mild steel grinding media. Carbon dioxide atmosphere in grinding created very reducing pulp environment, which caused very good concentrate quality. But the recovery was again poorer than with normal mild steel grinding media. Mixture of carbon dioxide and air as flotation gas improved PGE recovery with some ores, but not always. Effect of carbon dioxide to pulp electrochemistry was detected mainly via pH-value.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

N-Vinylamidderivate sind eine toxikologische unbedenkliche Monomerklasse. Mit diesen Monomeren wurden verschiedene technische Anwendungsgebiete im Bereich der Kern-Schale-Partikel und der fließfähigen und vernetzten Hydrogele untersucht. Kern-Schale-Partikel Für die Synthese von Kern-Schale-Partikeln wurden die N-Vinylamidderivate als Schalenpolymere auf kommerziellen Poly(styrol-stat.-butadien)-Kernpartikeln aufpolymerisiert. Mit Hilfe verschiedener Untersuchungsmethoden (DLS, SEM, FFF, Ultrazentrifuge) wurde die Kern-Schale-Strukturbildung und die Effizienz der Pfropfungsreaktion untersucht und eine erfolgreiche Synthese der Kern-Schale-Partikel belegt. Durch die gezielte Modifizierung des Schalenpolymers wurde ein kationisches, organisches Mikropartikelsystem entwickelt, charakterisiert und auf die Eignung als „Duales Flockungsmittel“ untersucht. Diese Versuche belegten die Eignung der modifizierten Kern-Schale-Partikel als „Duales Flockungsmittel“ und bieten eine Alternative zu kommerziell verwendeten Retentionsmitteln. Außerdem wurden die filmbildenden Eigenschaften der Poly(N﷓vinylformamid)-Kern-Schale-Dispersionen untersucht. Nach der Verfilmung der Dispersionen wurden transparente und harte Filme erhalten. Die Auswirkungen auf die mechanischen Eigenschaften der Filme wurden durch die Variation verschiedener Parameter eingehend studiert. Auf der Basis dieser Partikel wurden selbstvernetzende Dispersionssysteme entwickelt. Das P﷓(VFA)-Schalenpolymer wurde teilweise hydrolysiert und die generierten freien Aminogruppen des Poly(N-vinylamins) durch eine Michael-Addition mit einem divinylfunktionalisierten Acrylat (Tetraethylenglykoldiacrylat) vernetzt. Untersuchungen zur mechanischen Beständigkeit der Filme zeigten bei geringen Vernetzungsgraden eine deutliche Optimierung der maximalen Zugbelastungen. Die Untersuchungen belegten, dass die Verwendung des selbstvernetzenden Dispersionssystems als Dispersion für eine Polymerbeschichtung möglich ist. Hydrogele Die Synthese von fließfähigen und quervernetzten Hydrogelen erfolgte auf der Basis verschiedener N﷓Vinylamide. Mit Hilfe geeigneter Vernetzer wurden feste Hydrogelplatten synthetisiert und für die Auftrennung von DNA-Sequenzen mit Hilfe der Gelelektrophorese verwendet. Scharfe und gute Auftrennung der verschiedenen „DNA-Ladder Standards“ wurden durch die Variation des Vernetzeranteils, der Polymerzusammensetzung, der angelegten Spannung und der Verweilzeit in der Gelelektrophoresekammer mit P﷓(MNVA)-Hydrogelplatten erreicht. Fließfähige und quervernetzte Elektrolytgele auf Poly-(N-vinylamid)-Basis wurden in wartungsfreien pH﷓Elektroden eingesetzt. Die Eignung dieser Hydrogele wurden in Bezug auf die Anwendung eingehend charakterisiert. Elektroden befüllt mit Poly(N-vinylamid)-Gelen wurden in Dauerbelastungsexperimenten, direkt mit kommerziellen pH﷓Elektroden verglichen. Es konnte gezeigt werden, dass die fließfähigen und quervernetzten Poly-(N-vinylamid)-Elektrolytgele in ihren Messeigenschaften gleichwertige bzw. bessere Potentialstabilitäten aufweisen als kommerzielle Referenzelektroden. Die Hydrogele auf Basis von Poly(N-vinylamidderivaten) boten für die beiden getesteten Anwendungen eine toxikologisch unbedenkliche Alternative zu Poly(acrylamid)-Gelen. In dieser Arbeit konnten die durchgeführten Untersuchungen belegen, dass N﷓Vinylamide eine attraktive Monomerklasse ist, die erfolgreich in vielen technischen Anwendungen einsetzbar ist.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The interfacial properties of Pt(111) single crystal electrodes have been investigated in the pH range 3 < pH < 5 in order to obtain information about the acidity of electrosorbed water. Proper experimental conditions are defined to avoid local pH changes while maintaining the absence of specifically adsorbed anions and preserving the cleanliness of the solution. For this purpose, buffer solutions resulting from mixtures of NaF and HClO4 are used. Total charge curves are obtained at different pHs from the integration of the voltammetric currents in combination with CO charge displacement experiments. Analysis of the composition of the interphase as a function of the pH provides information for the understanding of the notion of interfacial pH.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The determination of the potentials of zero total and free charge, pztc and pzfc respectively, were made in a wide pH range by using the CO displacement method and the same calculation assumptions used previously for Pt(1 1 1) electrodes in contact with non-specifically adsorbing anions. Calculation of the pzfc involves, in occasions, long extrapolations that lead us to the introduction of the concept of potential of zero extrapolated charge (pzec). It was observed that the pztc changes with pH but the pzec is independent of this parameter. It was observed that the pztc > pzec at pH > 3.4 but the opposite is true for pH > 3.4. At the latter pH both pzec and pztc coincide. This defines two different pH regions and means that adsorbed hydrogen has to be corrected in the “acidic” solutions at the pztc while adsorbed OH is the species to be corrected in the “alkaline” range. The comparison of the overall picture suggests that neutral conditions at the interface are attained at significantly acidic solutions than those at the bulk.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Local changes of the interfacial pH can significantly affect the rate and mechanism during the course of an electrodic reaction. For instance, different pH values will have a significant effect on the equilibrium properties of both solution and surface species, altering the reactions kinetics. Ethanol oxidation at platinum electrodes in alkaline media involves the fast consumption of OH− species that will change the local pH at the electrode surface, decreasing the reaction rate. In this study, the local pH change during ethanol oxidation in alkaline media is accomplished by using rotating ring-disc electrode (RRDE) experiments. The current at the ring when polarized at the onset of hydrogen evolution serves as a measure of the local pH in the vicinity of the electrode. The results show that the current at the ring at 0.1 V (vs. RHE) becomes more negative during ethanol oxidation, owing to a change in the equilibrium potential of the hydrogen evolution reaction caused by a change in the local pH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and easy approach to produce polymeric microchips with integrated copper electrodes for capacitively coupled contactless conductivity detection (CD) is described. Copper electrodes were fabricated using a printed circuit board (PCB) as an inexpensive thin-layer of metal. The electrode layout was first drawn and laser printed on a wax paper sheet. The toner layer deposited on the paper sheet was thermally transferred to the PCB surface working as a mask for wet chemical etching of the copper layer. After the etching step, the toner was removed with an acetonitrile-dampened cotton. A poly(ethylene terephthalate) (PET) film coated with a thin thermo-sensitive adhesive layer was used to laminate the PCB plate providing an insulator layer of the electrodes to perform CID measurements. Electrophoresis microchannels were fabricated in poly(dimethylsiloxane) (PDMS) by soft lithography and reversibly sealed against the PET film. These hybrid PDMS/PET chips exhibited a stable electroosmotic mobility of 4.25 +/- 0.04 x 10(-4) V cm(-2) s(-1), at pH 6.1, over fifty runs. Efficiencies ranging from 1127 to 1690 theoretical plates were obtained for inorganic cations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work investigates the formation of self-assembled monolayers (SAMs) of cystamine and cystamine-glutaraldehyde on a screen-printed electrode, and the immobilization of the Tc85 protein (from Trypanosoma cruzi) on these monolayers. The methods used included infrared techniques, cyclic voltammetry, and electrochemical impedance spectroscopy. The electrochemical studies were performed at pH 6.9 in 0.1 mol L(-1) phosphate buffer solution containing Fe(CN)(6)(-3/-4) redox species. The surface coverage (0) of the electrode was 0.10 (cystamine), 0.35 (cystamine-glutaraldehyde) and 0.84 (Tc85). Interpretation of electrochemical impedance spectroscopy results was based on a charge-transfer reaction involving Fe(CN)(6)(-3/-4) species at high frequencies, followed by a diffusion through the monolayers at lower frequencies. Estimates of the electrode surface coverage, active site radius, and distance between two adjacent sites assumed that charge transfer occurred at the active sites, and that there was a planar diffusion of redox species to these sites. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper has investigated the electrochemical oxidation of glyphosate herbicide (GH) on RuO(2) and IrO(2) dimensionally stable anode (DSA (R)) electrodes. Electrolysis was achieved under galvanostatic control as a function of pH, GH concentration, supporting electrolyte, and current density. The influence of the oxide composition on GH degradation seems to be significant in the absence of chloride; Ti/Ir(0.30)Sn(0.70)O(2) is the best electrode material to oxidize GH. GH oxidation is favored at low pH values. The use of chloride medium increases the oxidizing power and the influence of the oxide composition is meaningless. At 30 mA cm(-2) and 4 h of electrolysis, complete GH removal from the electrolyzed solution has been obtained. In chloride medium, application of 50 mA cm(-2) leads to virtually total mineralization ( release of phosphate ions = 91%) for all the evaluated oxide materials. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Disposable screen-printed electrodes (SPCE) were modified using a cosmetic product to partially block the electrode surface in order to obtain a microelectrode array. The microarrays formed were electropolymerized with aniline. Scanning electron microscopy was used to evaluate the modified and polymerized electrode surface. Electrochemical characteristics of the constructed sensor for cadmium analysis were evaluated by cyclic and square-wave voltammetry. Optimized stripping procedure in which the preconcentration of cadmium was achieved by depositing at –1.20 V (vs. Ag/AgCl) resulted in a well defined anodic peak at approximately –0.7 V at pH 4.6. The achieved limit of detection was 4 × 10−9 mol dm−3. Spray modified and polymerized microarray electrodes were successfully applied to quantify cadmium in fish sample digests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a tartrate- (TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes showed behavior was best for membranes with o-nitrophenyl octyl ether as solvent. On injection of 500 μL into a phosphate buffer carrier (pH = 3.1; ionic strength 10–2 mol/L) flowing at 3 mL/min, the slope was 58.06 ± 0.6 with a lower limit of linear range of 5.0 × 10–4 mol/L TAT and R2 = 0.9989. The interference of several species, e.g. chloride, bromide, iodide, nitrate, gallic acid, tannin, sucrose, glucose, fructose, acetate, and citrate, was evaluated in terms of potentiometric selectivity coefficients. The Hofmeister series was followed for inorganic species and the most interfering organic ion was citrate. When red and white wines were analyzed and the results compared with those from an independent method they were found to be accurate, with relative standard deviations below 5.0%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system having a chlormequat selective electrode is proposed. Several electrodes with poly(vinyl chloride) based membranes were constructed for this purpose. Comparative characterization suggestedthe use of membrane with chlormequat tetraphenylborate and dibutylphthalate. On a single-line FIA set-up, operating with 1x10-2 mol L-1 ionic strength and 6.3 pH, calibration curves presented slopes of 53.6±0.4mV decade-1 within 5.0x10-6 and1.0x10-3 mol L-1, andsquaredcorrelation coefficients >0.9953. The detection limit was 2.2x10-6 mol L-1 and the repeatability equal to ±0.68mV (0.7%). A dual-channel FIA manifold was therefore constructed, enabling automatic attainment of previous ionic strength andpH conditions and thus eliminating sample preparation steps. Slopes of 45.5±0.2mV decade -1 along a concentration range of 8.0x10-6 to 1.0x10-3 mol L-1 with a repeatability ±0.4mV (0.69%) were obtained. Analyses of real samples were performed, and recovery gave results ranging from 96.6 to 101.1%.