918 resultados para PERMANENT PACEMAKER


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 +/- 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 +/- 12.8%, STS score 9.4 +/- 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.320.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.031.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. (c) 2011 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study sought to assess the impact of permanent pacemaker (PPM) implantation on clinical outcomes among patients undergoing transfemoral transcatheter aortic valve implantation (TAVI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Atrioventricular (AV) conduction disturbances requiring permanent pacemaker (PPM) implantation may complicate transcatheter aortic valve replacement (TAVR). Available evidence on predictors of PPM is sparse and derived from small studies. Objectives The objective of this study was to provide summary effect estimates for clinically useful predictors of PPM implantation after TAVR. Methods We performed a systematic search for studies that reported the incidence of PPM implantation after TAVR and that provided raw data for the predictors of interest. Data on study, patient, and procedural characteristics were abstracted. Crude risk ratios (RRs) and 95% confidence intervals for each predictor were calculated by use of random effects models. Stratified analyses by type of implanted valve were performed. Results We obtained data from 41 studies that included 11,210 TAVR patients, of whom 17% required PPM implantation after intervention. The rate of PPM ranged from 2% to 51% in individual studies (with a median of 28% for the Medtronic CoreValve Revalving System [MCRS] and 6% for the Edwards SAPIEN valve [ESV]). The summary estimates indicated increased risk of PPM after TAVR for men (RR: 1.23; p < 0.01); for patients with first-degree AV block (RR: 1.52; p < 0.01), left anterior hemiblock (RR: 1.62; p < 0.01), or right bundle branch block (RR: 2.89; p < 0.01) at baseline; and for patients with intraprocedural AV block (RR: 3.49; p < 0.01). These variables remained significant predictors when only patients treated with the MCRS bioprosthesis were considered. The data for ESV were limited. Unadjusted estimates indicated a 2.5-fold higher risk for PPM implantation for patients who received the MCRS than for those who received the ESV. Conclusions Male sex, baseline conduction disturbances, and intraprocedural AV block emerged as predictors of PPM implantation after TAVR. This study provides useful tools to identify high-risk patients and to guide clinical decision making before and after intervention.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Atrial fibrillation (AF) and heart failure (HF) are common and interrelated conditions, each promoting the other, and both associated with increased mortality. HF leads to structural and electrical atrial remodeling, thus creating the basis for the development and perpetuation of AF; and AF may lead to hemodynamic deterioration and the development of tachycardia-mediated cardiomyopathy. Stroke prevention by antithrombotic therapy is crucial in patients with AF and HF. Of the 2 principal therapeutic strategies to treat AF, rate control and rhythm control, neither has been shown to be superior to the other in terms of survival, despite better survival in patients with sinus rhythm compared with those in AF. Antiarrhythmic drug toxicity and poor efficacy are concerns. Catheter ablation of AF can establish sinus rhythm without the risks of antiarrhythmic drug therapy, but has important procedural risks, and data from randomized trials showing a survival benefit of this treatment strategy are still lacking. In intractable cases, ablation of the atrioventricular junction and placement of a permanent pacemaker is a treatment alternative; and biventricular pacing may prevent or reduce the negative consequences of chronic right ventricular pacing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: Alcohol ablation (AA) of the septum has been introduced as new therapy in hypertrophic cardiomyopathy (HCM). It was feared that iatrogenic myocardial infarction due to AA may induce re-entry tachyarrhythmias and increase sudden cardiac death. METHODS AND RESULTS: Twenty-four patients (mean age 52 years) underwent successful AA. Clinical follow-up (FU) ranged from 0.3 to 0.7 years (mean 2.8). One patient died (suicide) 4 years after AA. Left ventricular (LV) outflow gradient (peak-to-peak) decreased (median) after AA from 43 (IQR 25 to 4) mmHg to 1 (IQR 0 to 12) mmHg (rest) (p <0.001) and from 130 (IQR 75 to 165) mmHg to 13 (IQR 0 to 31) mmHg (postextrasystolic) (p <0.001). Transient AV block occurred in 22% (5/24) necessitating temporary pacing. A permanent pacemaker was implanted in 4% (1/24). NYHA-class was 2.5 (IQR 2.0 to 3.0) before and 1.5 (IQR 1.3 to 2.0) (p <0.001) after AA. During FU, 2 pacemakers were implanted due to bradycardia (no AV block). A right bundle branch block was found in 13% (2/24) before and 46 % (11/24) after AA (p = 0.003). Non-sustained ventricular tachycardia (NSVT) was observed in 13% (2/16) before and 22% (5/23) (p = 0.46) after AA. Two patients required ICD implantation. CONCLUSIONS: Long-term FU is excellent in HCM after AA. The pressure gradient drops below 25 mm Hg in 95% (23/24) of all patients. Transient AV block occurs in 22% (5/24), but permanent pacemaker implantation is rarely needed (13%, 2/24). Severe NSVT occurs in 13% (2/16) before and 22% (5/23) after AA but ICD implantation is only occasionally required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: This study reviews our experience with the Ross procedure in infants and young children. METHODS: From September 1993 to September 2004, 52 children less than 15 years of age underwent a Ross procedure. The patients ranged in age from 4 days to 15 years old (median, 5 years). Fifteen patients (29%) were less than 2 years of age. The predominant indication for the Ross procedure was aortic stenosis. Sixteen patients underwent a Ross-Konno procedure for severe left ventricular outflow tract obstruction. Thirty-four patients had 48 previous interventions. Preoperatively, 6 patients showed severe left ventricular dysfunction, and 2 of the patients required ventilation and inotropic support. Concomitant procedures were performed in 8 patients. Three patients had a mitral valve replacement, 2 patients had a ventricular septal defect closure and an aortic arch reconstruction, 2 patients had aortic arch reconstructions, and 1 patient had resection of a coarctation and a ventricular septal defect closure. RESULTS: Patients were followed up for a median of 43 months (range, 1 to 130). Overall survival was 85% +/- 5% at 1 and 82% +/- 5% at 2, 5, and 10 years. Hospital mortality was 5 of 52 patients (9.6%). All deaths occurred in neonates or infants less than 2 months of age, who needed urgent surgery. Three patients died late of noncardiac causes. At last follow-up, all patients were classified in New York Heart Association functional class I or II. No patient had endocarditis of the autograft or the right ventricular outflow tract replacement. During the follow-up, no event of thrombembolism was observed. No patient required the insertion of a permanent pacemaker. Overall freedom from reoperation is 57% +/- 15% at 10 years. One patient required the replacement of the autograft at 6 months postoperatively. The development of mild aortic insufficiency was observed in 24 patients, and moderate aortic insufficiency in 1 patient during follow-up. Freedom from reoperation for the right ventricular outflow tract replacement is 60% +/- 15% at 10 years. CONCLUSIONS: The Ross procedure represents an attractive approach to aortic valve disease in young children. However, a high early mortality rate has to be considered when performing this procedure in neonates or infants who present in critical preoperative condition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Grâce à une collaboration entre des cardiologues suisses, la Fondation Cœur de la Tour et l’Hôpital universitaire BPKIHS à Dharan, il a été possible en l’espace de deux ans, en utilisant une approche «hybride», de développer le premier programme de cardiologie invasive et interventionnelle indépendant dans l’est du Népal. Depuis janvier 2011, 496 patients ont pu être investigués et traités en 23 mois (coronarographies, angioplasties coronaires, pose de pacemakers temporaires et définitifs, drainages péricardiques, etc.). Parallèlement à cet axe principal, la Fondation a également soutenu un programme préexistant de prévention des facteurs de risque cardio-vasculaires dans cette région, et a apporté un appui financier à la mise sur pied d’un projet de dépistage et de traitement des atteintes cardiaques rhumatismales chez les enfants en âge scolaire.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. Methods and results: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm2) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). Conclusions: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article provides an overview on procedure-related issues and uncertainties in outcomes after transcatheter aortic valve implantation (TAVI). The different access sites and how to select them in an individual patient are discussed. Also, the occurrence and potential predictors of aortic regurgitation (AR) after TAVI are addressed. The different methods to quantify AR are reviewed, and it appears that accurate and reproducible quantification is suboptimal. Complications such as prosthesis-patient mismatch and conduction abnormalities (and need for permanent pacemaker) are discussed, as well as cerebrovascular events, which emphasize the development of optimal anti-coagulative strategies. Finally, recent registries have shown the adoption of TAVI in the real world, but longer follow-up studies are needed to evaluate the outcome (but also prosthesis durability). Additionally, future studies are briefly discussed, which will address the use of TAVI in pure AR and lower-risk patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV (S3) versus the Sapien XT THV (XT) were investigated. An overall of 153 consecutive S3 patients were compared with 445 consecutive XT patients. Postprocedural mean transprosthetic gradient (6.5±3.0 versus 7.8±6.3 mm Hg, P=0.17) did not differ between S3 and XT patients, respectively. The rate of more than mild paravalvular regurgitation (1.3% versus 5.3%, P=0.04) and of vascular (5.3% versus 16.9%, P<0.01) complications were significantly lower in S3 patients. A higher rate of new permanent pacemaker implantations was observed in patients receiving the S3 valve (17.0% versus 11.0%, P=0.01). There were no significant differences for disabling stroke (S3 1.3% versus XT 3.1%, P=0.29) and all-cause mortality (S3 3.3% versus XT 4.5%, P=0.27). CONCLUSIONS The use of the new generation S3 balloon-expandable THV reduced the risk of more than mild paravalvular regurgitation and vascular complications but was associated with an increased permanent pacemaker rate compared with the XT. Transcatheter aortic valve implantation using the newest generation balloon-expandable THV is associated with a low risk of stroke and favorable clinical outcomes. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01368250.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) region can be inaccessible for ablation because of epicardial fat or overlying coronary arteries. OBJECTIVE We describe surgical cryoablation of this type of VA. METHODS From March 2009 to 2014, 190 consecutive patients with VAs originating from the LVOT underwent ablation at our institution. Four patients (2%) underwent surgical cryoablation for highly symptomatic VAs after failing catheter ablation. RESULTS In all patients, endocardial or percutaneous epicardial mapping was consistent with origin in the LVOT. In 2 patients, the points of earliest activation during VAs were marked with a bipolar pacing lead in the overlying cardiac vein for guidance during surgery. Surgical cryoablation was successful in 3 of the 4 patients. The fourth patient subsequently had successful endocardial catheter ablation. During a mean follow-up of 22 ± 16 months (range 4-42 months), all patients showed abolition of or marked reduction in symptomatic VA. However, 1 patient subsequently required percutaneous intervention to the left anterior descending coronary artery; another developed progressive left ventricular systolic dysfunction caused by nonischemic cardiomyopathy; and a third patient underwent permanent pacemaker implantation because of complete atrioventricular block after concomitant aortic valve replacement. CONCLUSION Surgical cryoablation is an option for highly symptomatic drug-resistant VAs emanating from the LVOT region. Despite extensive preoperative mapping, the procedure is not effective for all patients, and coronary injury is a risk.