71 resultados para NORFLOXACIN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A kinetic spectrophotometric method with aid of chemometrics is proposed for the simultaneous determination of norfloxacin and rifampicin in mixtures. The proposed method was applied for the simultaneous determination of these two compounds in pharmaceutical formulation and human urine samples, and the results obtained are similar to those obtained by high performance liquid chromatography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526 nm, and the accompanying increase of the product, potassium manganate, at 608 nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0–11.5 mg L−1 at 526 and 608 nm for pefloxacin, and 0.15–1.8 mg L−1 at 526 and 608 nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526 nm, were the preferred methods—%RPET not, vert, similar 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06 mg L−1, respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The inhibiting effect and mechanism of 1-cyclopropyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylicacid(ciprofloxacin), 1-ethyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid (norfloxacin) and (-)-(S)-9-fluoro-2,3-dihydro-3-methyl-10-(4-methyl-1-piperazinyl)-7-oxo-7 H-pyrido(1,2,3-de)-1,4-benzoxazine-6 carboxylic acid (ofloxacin) on the corrosion of mild steel in 1 mol/L HCl have been studied using electrochemical method, quantum chemical method and SEM at 303 K. The potentiodynamic results showed that these compounds suppressed both cathodic and anodic processes of mild steel corrosion in 1 mol/L HCl. The impedance spectroscopy showed that R-p values increased, and C-dl values decreased with the rising of the working concentration. Quantum chemical calculation showed that there was a positive correlation between some inhibitors structure properties and the inhibitory efficiency. The inhibitors function through adsorption followed Langmuir isotherm, and chemisorption made more contribution to the adsorption of the inhibitors on the steel surface compared with physical adsorption. SEM analysis suggested that the metal had been protected from aggressive corrosion because of the addition of the inhibitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μgmL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μgmL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0 μg mL−1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2 mV per decade, a linear range from 79 μM to 2.5 mM, a detection limit of 20 μg mL−1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomimetic sensor is proposed as a promising new analytical method for determination of norfloxacin (NF) in pharmaceuticals. The sensor was prepared by modifying a glassy carbon electrode surface with a Nafion® membrane doped with poly(copper phthalocyanine) complex [poly-CuPc]. Amperometric measurements carried out with the sensor under an applied potential of -0.05 V vs Ag|AgCl in 0.1 mol L-1 acetic acid containing 1.5 × 10-3 mol L-1 hydrogen peroxide showed a linear response range from 2.0 × 10-4 to 1.2 × 10-3 mol L-1. Selectivity and interference studies were also performed. A sensor response mechanism is proposed, based on the experimental evidence. Recovery studies were carried out using environmental samples, in order to evaluate the sensor’s potential for use with these sample classes. Finally, sensor performance was evaluated using analyses of commercial formulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stability-indication high performance liquid chromatographic method has been developed for the determination of norfloxacin in tablet dosage forms. Optimum separation was achieved in less than 7 minutes using Eclipse Plus Zorbax C18 Agilent, 150 mm×4.6 mm i.d., 5 μm particle size column. The analyte was resolved by using a mobile phase 5% acetic acid aqueous solution and methanol (80:20, v/v) at a flow rate 1.0 ml/min on an isocratic high performance liquid chromatographic system at a wavelength of 277 nm. Linearity, system suitability, precision, sensitivity, selectivity, specific, and robustness were established by International Conference Harmonization guidelines. For stress studies the drug was subjected to photolysis, oxidation, acid, alkaline and neutral conditions. The analytical conditions and the solvent developed provided good resolution within a short analysis time and economic advantages. The proposed method not required sophisticated and expensive instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esse trabalho compreende dois diferentes estudos de caso: o primeiro foi a respeito de um medicamento para o qual foi desenvolvida uma metodologia para determinar norfloxacino (NOR) por espectrofluorimetria molecular e validação por HPLC. Primeiramente foi desenvolvida uma metodologia por espectrofluorimetria onde foram feitos alguns testes preliminares a fim de estabelecer qual valor de pH iria fornecer a maior intensidade de emissão. Após fixar o pH foi feita a determinação de NOR em padrões aquosos e soluções do medicamento usando calibração univariada. A faixa de concentração trabalhada foi de 0500 μg.L-1. O limite de detecção para o medicamento foi de 6,9 μg.L-1 enquanto que o de quantificação foi de 24,6 μg.L-1. Além dessas, outras figuras de mérito também foram estimadas para desenvolvimento da metodologia e obtiveram resultados muito satisfatórios, como por exemplo, os testes de recuperação no qual a recuperação do analito foi de 99.5 a 103.8%. Para identificação e quantificação do NOR da urina foi necessário diluir a amostra de urina (estudada em dois diferentes níveis de diluição: 500 e 1000 x) e também uso do método da adição de padrão (na mesma faixa de concentração usada para medicamento). Após a aquisição do espectro, todos foram usados para construção do tensor que seria usado no PARAFAC. Foi possível estimar as figuras de mérito como limite de detecção de 11.4 μg.L-1 and 8.4 μg.L-1 (diluição de 500 e 1000 x respectivamente) e limite de quantificação de 34 μg.L-1 e 25.6 μg.L-1 (diluição de 500 x e 1000 x respectivamente). O segundo estudo de caso foi na área alimentícia no qual se usou espectroscopia NIR e FT MIR acopladas a quimiometria para discriminar óleo de soja transgênica e não transgênica. Os espectros dos óleos não mostraram diferença significativa em termos visuais, sendo necessário usar ferramentas quimiométricas capazes de fazer essa distinção. Tanto para espectroscopia NIR quanto FT MIR foi feito o PCA a fim de identificar amostras discrepantes e que influenciariam o modelo de forma negativa. Após efetuar o PCA, foram usadas três diferentes técnicas para discriminar os óleos: SIMCA, SVM-DA e PLS-DA, sendo que para cada técnica foram usados também diferentes pré processamento. No NIR, apenas para um pré processamento se obteve resultados satisfatórios nas três técnicas, enquanto que para FT-MIR ao se usar PLS-DA se obteve 100% de acerto na classificação para todos os pré processamentos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Descrever a prevalência das espécies bacterianas isoladas nas infecções urinárias comunitárias. Descrever os perfis de susceptibilidade aos antibióticos de uso oral utilizado frente às bactérias isoladas nas infecções urinárias comunitárias. Avaliar a prevalência de fenótipos de resistência bacterianos através dos resultados dos testes de susceptibilidade e dos rastreamentos específicos utilizados. Amostras colhidas exclusivamente no atendimento ambulatorial com contagens de unidades formadoras de colônias entre 100.000 a ≥1.000.000 por mililitro (UCF/ml) Com ou sem piúria no exame de elementos anormais na urina e sedimentoscopia (EAS). Foram analisados retrospectivamente os resultados de urinoculturas e dos testes de susceptibilidade a antimicrobianos, realizados em um Laboratório da rede privada na cidade do Rio de janeiro, de pacientes atendidos em ambulatórios e com quadros de ITU. As amostras de urina coletadas englobavam basicamente os seguintes bairros: Botafogo, Barra da Tijuca, Ipanema, Copacabana, Tijuca e Centro. Foram analisados um total de 8.475 culturas de urina divididas em 7.286 urinas de pacientes femininos e 1.189 de pacientes masculinos entre Janeiro de 2006 a Dezembro de 2012. As amostras foram todas coletadas na Cidade do Rio de Janeiro e englobavam basicamente os seguintes bairros: Botafogo, Barra da Tijuca, Ipanema, Copacabana, Tijuca e Centro. Encontramos um percentual de resistência de 27% para ciprofloxacina frente à Escherichia coli que com 68.23% é a principal etiologia encontrada na ITU na comunidade os resultados das três fluoroquinolonas avaliadas no estudo, ciprofloxacina (2 geração), levofloxacina (3 geração) e norfloxacina (2 geração), acharemos respectivamente 27%, 25% e 20% de resistência em Escherichia coli. O uso de fluoroquinolonas em infecções urinárias comunitárias e consequentemente os achados de padrões de resistência neste estudo, reforçam o que já foi descrito em outros trabalhos. A cefalosporina de 2 geração (cefuroxima), demonstrou percentuais de resistência bastante satisfatórios frente as principais etiologias. Em Escherichia coli o percentual foi de 2%, em Klebsiella pneumoniae 3% e em Proteus mirabilis não houve nenhum achado de resistência. Uma das vantagens da cefuroxima é ser ativa quanto à produção de beta lactamase, conferindo um espectro maior frente a possíveis produtoras desta enzima. Seu esquema posológico é de 250mg duas vezes ao dia por 7 dias para infecções urinárias não complicadas. O meio mais eficaz de melhorar a administração antimicrobiana provavelmente envolverá um programa abrangente que incorpora múltiplas estratégias e colaboração entre as diversas especialidades dentro de uma determinada instituição de saúde. Neste contexto, a observação periódica da incidência bacteriana com seus respectivos índices de resistência aos antimicrobianos por sitio de infecção e correlação com os antibióticos mais comumente utilizados, é mandatória para o sucesso terapêutico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A invasão de bactérias no trato urinário caracteriza a infecção do sistema urinário. A Escherichia coli é o principal microrganismo associado a esta infecção devido a sua importância em causar ITU, recebeu a denominação de UPEC (Escherichia coli uropatogênica). No presente trabalho pesquisamos em 50 cepas de UPEC, inicialmente isolados de urina de pacientes ambulatoriais com infecções sintomática ou assintomática, a presença de 7 fatores de virulência, através das técnicas de PCR simples e multiplex para verificação dos genes que codificam adesinas P (pap) , fímbria S (sfa), adesina afimbrial (afa), sideroforo (aerobactina- aer), toxinas fator necrotizante citotóxico (cnf) e alfa-hemolisinas (hly), proteína de membrana (traT); ilhas de patogenicidade (virulência) através do marcador PAI. O marcador pCVD432 de EAEC também foi pesquisado nestas amostras. O método difusão em disco foi o utilizado para a determinação dos testes de susceptibilidade aos antimicrobianos. Podemos observar duas faixas etárias de maior incidência de ITU entre as mulheres: 19 a 35 anos, e acima de 50 anos. Sessenta e oito por cento das amostras apresentaram pelo menos um fator de virulência, onde os genes traT (54%) e aer (34%) foram os mais prevalentes. A sequência pCVD432 foi detectado em 6 amostras. No entanto, no ensaio de adesão em células Hep-2, doze amostras não apresentaram aderência (NA 24%). Nas 38 cepas restantes, 24 (48%) apresentaram aderência agregativa (AA). Observamos aderência sem padrão típico (SPT) em 48% das amostras, tendo sido dividido em discreto (SPT-D 22%), moderado (SPT-M 18%) e intenso (SPT-I 8%). Notamos os seguintes perfis de resistência para os antimicrobianos testados: ampicilina (44%), gentamicina (8%), nitrofurantoína (2%), norfloxacino (18%) e sulfametozaxol-trimetoprima (34%).