867 resultados para Musculoskeletal pain Reliability Validity Outcome Factor analysis Clinimetric Measurement
Resumo:
During the last decade, a multi-modal approach has been established in human experimental pain research for assessing pain thresholds and responses to various experimental pain modalities. Studies have concluded that differences in responses to pain stimuli are mainly related to variation between individuals rather than variation in response to different stimulus modalities. In a factor analysis of 272 consecutive volunteers (137 men and 135 women) who underwent tests with different experimental pain modalities, it was determined whether responses to different pain modalities represent distinct individual uncorrelated dimensions of pain perception. Volunteers underwent single painful electrical stimulation, repeated painful electrical stimulation (temporal summation), test for reflex receptive field, pressure pain stimulation, heat pain stimulation, cold pain stimulation, and a cold pressor test (ice water test). Five distinct factors were found representing responses to 5 distinct experimental pain modalities: pressure, heat, cold, electrical stimulation, and reflex-receptive fields. Each of the factors explained approximately 8% to 35% of the observed variance, and the 5 factors cumulatively explained 94% of the variance. The correlation between the 5 factors was near null (median ρ=0.00, range -0.03 to 0.05), with 95% confidence intervals for pairwise correlations between 2 factors excluding any relevant correlation. Results were almost similar for analyses stratified according to gender and age. Responses to different experimental pain modalities represent different specific dimensions and should be assessed in combination in future pharmacological and clinical studies to represent the complexity of nociception and pain experience.
Resumo:
Background: Pain and anxiety are a common problem in all recovery phases after a burn. The Burns Specific Pain Anxiety Scale (BSPAS) was proposed to assess anxiety in burn patients related to painful procedures. Objectives: To assess internal consistency, discriminative construct validity, dimensionality and convergent construct validity of the Brazilian-Portuguese version of the Burns Specific Pain Anxiety Scale. Design: In this cross-sectional study, the original version of the BSPAS, adapted into Brazilian Portuguese, was tested for internal consistency (Cronbach`s Alpha), discriminative validity (related to total body surface area burned and sex), dimensionality (through factor analysis), and convergent construct validity (applying the Visual Analogue Scale for pain and State-Anxiety-STAI) in a group of 91 adult burn patients. Results: The adapted version of the BSPAS displayed a moderate and positive correlation with pain assessments: immediately before baths and dressings (r = 0.32; p < 0.001), immediately after baths and dressings (r = 0.31; p < 0.001) and during the relaxation period (r= 0.31; p < 0.001) and with anxiety assessments (r = 0.34; p < 0.001). No statistically significant differences were observed when comparing the mean of the adapted version of the BSPAS scores with sex (p = 0.194) and total body surface area burned (p = 0.162) (discriminative validity). The principal components analysis applied to our sample seems to confirm anxiety as one single domain of the Brazilian-Portuguese version of the BSPAS. Cronbach`s Alpha showed high internal consistency of the adapted version of the scale (0.90). Conclusion: The Brazilian-Portuguese version of the BSPAS 9-items has shown statically acceptable levels of reliability and validity for pain-related anxiety evaluation in burn patients. This scale can be used to assess nursing interventions aimed at decreasing pain and anxiety related to the performance of painful procedures. (c) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The original 'Örebro Musculoskeletal Pain Questionnaire' (original-ÖMPQ) has been shown to have limitations in practicality, factor structure, face and content validity. This study addressed these concerns by modifying its content producing the 'Örebro Musculoskeletal Screening Questionnaire' (ÖMSQ). The ÖMSQ and original-ÖMPQ were tested concurrently in acute/subacute low back pain working populations (pilot n = 44, main n = 106). The ÖMSQ showed improved face and content validity, which broadened potential application, and improved practicality with two-thirds less missing responses. High reliability (0.975, p < 0.05, ICC: 2.1), criterion validity (Spearman's r = 0.97) and internal consistency (α = 0.84) were achieved, as were predictive ability cut-off scores from ROC curves (112-120 ÖMSQ-points), statistically different ÖMSQ scores (p < 0.001) for each outcome trait, and a strong correlation with recovery time (Spearman's, r = 0.71). The six-component factor structure reflected the constructs originally proposed. The ÖMSQ can be substituted for the original-ÖMPQ in this population. Further research will assess its applicability in broader populations.
Resumo:
BACKGROUND CONTEXT: Studies involving factor analysis (FA) of the items in the North American Spine Society (NASS) outcome assessment instrument have revealed inconsistent factor structures for the individual items. PURPOSE: This study examined whether the factor structure of the NASS varied in relation to the severity of the back/neck problem and differed from that originally recommended by the developers of the questionnaire, by analyzing data before and after surgery in a large series of patients undergoing lumbar or cervical disc arthroplasty. STUDY DESIGN/SETTING: Prospective multicenter observational case series. PATIENT SAMPLE: Three hundred ninety-one patients with low back pain and 553 patients with neck pain completed questionnaires preoperatively and again at 3 to 6 and 12 months follow-ups (FUs), in connection with the SWISSspine disc arthroplasty registry. OUTCOME MEASURES: North American Spine Society outcome assessment instrument. METHODS: First, an exploratory FA without a priori assumptions and subsequently a confirmatory FA were performed on the 17 items of the NASS-lumbar and 19 items of the NASS-cervical collected at each assessment time point. The item-loading invariance was tested in the German version of the questionnaire for baseline and FU. RESULTS: Both NASS-lumbar and NASS-cervical factor structures differed between baseline and postoperative data sets. The confirmatory analysis and item-loading invariance showed better fit for a three-factor (3F) structure for NASS-lumbar, containing items on "disability," "back pain," and "radiating pain, numbness, and weakness (leg/foot)" and for a 5F structure for NASS-cervical including disability, "neck pain," "radiating pain and numbness (arm/hand)," "weakness (arm/hand)," and "motor deficit (legs)." CONCLUSIONS: The best-fitting factor structure at both baseline and FU was selected for both the lumbar- and cervical-NASS questionnaires. It differed from that proposed by the originators of the NASS instruments. Although the NASS questionnaire represents a valid outcome measure for degenerative spine diseases, it is able to distinguish among all major symptom domains (factors) in patients undergoing lumbar and cervical disc arthroplasty; overall, the item structure could be improved. Any potential revision of the NASS should consider its factorial structure; factorial invariance over time should be aimed for, to allow for more precise interpretations of treatment success.
Resumo:
Background context Studies involving factor analysis (FA) of the items in the North American Spine Society (NASS) outcome assessment instrument have revealed inconsistent factor structures for the individual items. Purpose This study examined whether the factor structure of the NASS varied in relation to the severity of the back/neck problem and differed from that originally recommended by the developers of the questionnaire, by analyzing data before and after surgery in a large series of patients undergoing lumbar or cervical disc arthroplasty. Study design/setting Prospective multicenter observational case series. Patient sample Three hundred ninety-one patients with low back pain and 553 patients with neck pain completed questionnaires preoperatively and again at 3 to 6 and 12 months follow-ups (FUs), in connection with the SWISSspine disc arthroplasty registry. Outcome measures North American Spine Society outcome assessment instrument. Methods First, an exploratory FA without a priori assumptions and subsequently a confirmatory FA were performed on the 17 items of the NASS-lumbar and 19 items of the NASS-cervical collected at each assessment time point. The item-loading invariance was tested in the German version of the questionnaire for baseline and FU. Results Both NASS-lumbar and NASS-cervical factor structures differed between baseline and postoperative data sets. The confirmatory analysis and item-loading invariance showed better fit for a three-factor (3F) structure for NASS-lumbar, containing items on “disability,” “back pain,” and “radiating pain, numbness, and weakness (leg/foot)” and for a 5F structure for NASS-cervical including disability, “neck pain,” “radiating pain and numbness (arm/hand),” “weakness (arm/hand),” and “motor deficit (legs).” Conclusions The best-fitting factor structure at both baseline and FU was selected for both the lumbar- and cervical-NASS questionnaires. It differed from that proposed by the originators of the NASS instruments. Although the NASS questionnaire represents a valid outcome measure for degenerative spine diseases, it is able to distinguish among all major symptom domains (factors) in patients undergoing lumbar and cervical disc arthroplasty; overall, the item structure could be improved. Any potential revision of the NASS should consider its factorial structure; factorial invariance over time should be aimed for, to allow for more precise interpretations of treatment success.
Resumo:
Aims. The aims of this study were to assess the internal reliability (internal consistency), construct validity, sensitivity and ceiling and floor effects of the Brazilian-Portuguese version of the Impact of Event Scale (IES). Design. Methodological research design. Method. The Brazilian-Portuguese version of the IES was applied to a group of 91 burned patients at three times: the first week after the burn injury (time one), between the fourth and the sixth months (time two) and between the ninth and the 12th months (time three). The internal consistency, construct validity (convergent and dimensionality), sensitivity and ceiling and floor effects were tested. Results. Cronbach`s alpha coefficients showed high internal consistency for the total scale (0 center dot 87) and for the domains intrusive thoughts (0 center dot 87) and avoidance responses (0 center dot 76). During the hospitalisation (time one), the scale showed low and positive correlations with pain measures immediately before (r = 0 center dot 22; p < 0 center dot 05) and immediately after baths and dressings (r = 0 center dot 21; p < 0 center dot 05). After the discharge, we found strong and negative correlations with self-esteem (r = -0 center dot 52; p < 0 center dot 01), strong and positive with depression (r = 0 center dot 63; p < 0 center dot 01) and low and negative with the Bodily pain (r = -0 center dot 24; p < 0 center dot 05), Social functioning (r = -0 center dot 34; p < 0 center dot 01) and Mental health (r = -0 center dot 27; p < 0 center dot 05) domains of the SF-36 at time two. Regarding the sensitivity, no statistically significant differences were observed between mean scale scores according to burned body surface (p = 0 center dot 21). The floor effect was observed in most of the IES items. Conclusion. The adapted version of the scale showed to be reliable and valid to assess postburn reactions on the impact of the event in the group of patients under analysis. Relevance to clinical practice. The Impact of Event Scale can be used in research and clinical practice to assess nursing interventions aimed at decreasing stress during rehabilitation.
Resumo:
Objectif: La réparation de la valve mitrale constitue le traitement de choix pour restaurer ta fonction de celle-ci. Elle est actuellement reconnue pour garantir une bonne évolution à long terme. Dans le but de faciliter les décisions périopératoires, nous avons analysé nos patients afin de déterminer les facteurs de risque ayant affecté leur évolution. Méthodes: Nous avons étudié rétrospectivement 175 premiers patients consécutifs (âge moyen : 64 +/-10.4 ans ;113 hommes) qui ont subi une réparation primaire de la valve mitrale associée à toute autre intervention cardiaque entre 1986 et 1998. Les facteurs de risque influençant le taux de réopération et la survie à long terme ont été analysés de manière uni et multivariée. Résultats: La mortalité opératoire était de 3.4 % (6 décès, 0 -22 et jours post-opératoires). La mortalité tardive était de 9.1 % (16 décès, 3e-125e mois post-opératoires). Cinq patients ont dû être réopérés. L'analyse actuarielle selon Kaplan-Meier a montré une survie à 1 année de 96 +l-1 %, une survie à 5 ans de 88 +/- 3 % et une survie à 10 ans de 69 +/- 8 %. Après 1 année, la fraction de population sans réopération était de 99 %, elle était de 97 +/-2 % après 5 ans et de 88+/-6 % après 10 ans. L'analyse multivariée a montré qu' un stade NYHA III et IV résiduel ( p=0.001, RR 4.55, 95 % IC :1.85 -14.29), une mauvaise fraction d'éjection préopératoire(p=0.013, RR 1.09, 95 % IC 1.02 -1.18), ,une régurgitation mitrale d'origine fonctionnelle (p=0.018, RR 4.17, 95% IC 1.32-16.67) ainsi qu'une étiologie ischémique (p=0.049, RR 3.13, 95% IC 1.01-10.0) constituaient tous des prédicteurs indépendant de mortalité. Une régurgitation mitrale persistante au 7 e jour post-opératoire (p= 0.005, RR 4.55, 95 % IC :1.56 -20.0), un âge inférieur à 60 ans (p = 0.012, RR 8.7, 95 % IC 2.44 - 37.8) et l'absence d'anneau prothétique (p = 0.034, RR 4.76, 95 % IC 1.79-33.3) se sont tous révélés être des facteurs de risque indépendant de réopération. Conclusion: Les réparations mitrales sont accompagnées d'une excellente survie à long terme même si leur évolution peut être influencée négativement par de nombreux facteurs de risques periopératoires. Les risques de réopération sont plus élevés chez des patients jeunes présentant une régurgitation mitrale résiduelle et n'ayant pas bénéficié de la mise en place d'un anneau prothétique.
Identification-commitment inventory (ICI-Model): confirmatory factor analysis and construct validity
Resumo:
The aim of this study is to confirm the factorial structure of the Identification-Commitment Inventory (ICI) developed within the frame of the Human System Audit (HSA) (Quijano et al. in Revist Psicol Soc Apl 10(2):27-61, 2000; Pap Psicól Revist Col Of Psicó 29:92-106, 2008). Commitment and identification are understood by the HSA at an individual level as part of the quality of human processes and resources in an organization; and therefore as antecedents of important organizational outcomes, such as personnel turnover intentions, organizational citizenship behavior, etc. (Meyer et al. in J Org Behav 27:665-683, 2006). The theoretical integrative model which underlies ICI Quijano et al. (2000) was tested in a sample (N = 625) of workers in a Spanish public hospital. Confirmatory factor analysis through structural equation modeling was performed. Elliptical least square solution was chosen as estimator procedure on account of non-normal distribution of the variables. The results confirm the goodness of fit of an integrative model, which underlies the relation between Commitment and Identification, although each one is operatively different.
Resumo:
P>The use of seven domains for the Oral Health Impact Profile (OHIP)-EDENT was not supported for its Brazilian version, making data interpretation in clinical settings difficult. Thus, the aim of this study was to assess patients` responses for the translated OHIP-EDENT in a group of edentulous subjects and to develop factor scales for application in future studies. Data from 103 conventional and implant-retained complete denture wearers (36 men, mean age of 69 center dot 1 +/- 10 center dot 3 years) were assessed using the Brazilian version of the OHIP-EDENT. Oral health-related quality of life domains were identified by factor analysis using principal component analysis as the extraction method, followed by varimax rotation. Factor analysis identified four factors that accounted for 63% of the 19 items total variance, named masticatory discomfort and disability (four items), psychological discomfort and disability (five items), social disability (five items) and oral pain and discomfort (five items). Four factors/domains of the Brazilian OHIP-EDENT version represent patient-important aspects of oral health-related quality of life.
Resumo:
This study aimed at evaluating the validity, reliability, and factorial invariance of the complete (34-item) and shortened (8-item and 16-item) versions of the Body Shape Questionnaire (BSQ) when applied to Brazilian university students. A total of 739 female students with a mean age of 20.44 (standard deviation = 2.45) years participated. Confirmatory factor analysis was conducted to verify the degree to which the one-factor structure satisfies the proposal for the BSQ's expected structure. Two items of the 34-item version were excluded because they had factor weights (lambda)< 40. All models had adequate convergent validity (average variance extracted =.43-.58; composite reliability=.85-.97) and internal consistency (alpha =.85-.97). The 8-item B version was considered the best shortened BSQ version (Akaike information criterion = 84.07, Bayes information criterion = 157.75, Browne-Cudeck criterion= 84.46), with strong invariance for independent samples (Delta chi(2)lambda(7)= 5.06, Delta chi(2)Cov(8)= 5.11, Delta chi(2)Res(16) = 19.30). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE: Maintenance of good walking speed is essential to independent living. People with musculoskeletal disease often have reduced walking speed. We investigated determinants of slower walking, other than musculoskeletal disease, that might provide valuable additional targets for therapy. METHODS: We analyzed data from the Somerset and Avon Survey of Health, a community based survey of people aged over 35 years. A total of 2703 participants who reported hip or knee pain at baseline (1994/1995) were studied, and reassessed in 2002-2003; 1696 were available for followup, and walking speed was tested in 1074. Walking speed (m/s) was used as outcome measure. Baseline characteristics, including comorbidities and socioeconomic factors, were tested for their ability to predict reduced walking speed using multiple linear regression analysis. RESULTS: Age, female sex, and immobility at baseline were predictive of slower walking speed. Other independent risk factors included the presence of cataract, low socioeconomic status, intermittent claudication, and other cardiovascular conditions. Having a cataract was associated with a decrease of 0.10 m/s (95% CI 0.03, 0.16). Those in social class V had a walking speed 0.22 m/s (95% CI 0.126, 0.31) slower than those in social class I. CONCLUSION: Comorbidities, age, female sex, and lower socioeconomic position determine walking speed in people with joint pain. Issues such as poor vision and social-economic disadvantage may add to the effect of musculoskeletal disease, suggesting the need for a holistic approach to management of these patients.
Resumo:
Synaesthesia is a heterogeneous phenomenon, even when considering one particular sub-type. The purpose of this study was to design a reliable and valid questionnaire for grapheme-colour synaesthesia that captures this heterogeneity. By the means of a large sample of 628 synaesthetes and a factor analysis, we created the Coloured Letters and Numbers (CLaN) questionnaire with 16 items loading on 4 different factors (i.e., localisation, automaticity/attention, deliberate use, and longitudinal changes). These factors were externally validated with tests which are widely used in the field of synaesthesia research. The questionnaire showed good test–retest reliability and construct validity (i.e., internally and externally). Our findings are discussed in the light of current theories and new ideas in synaesthesia research. More generally, the questionnaire is a useful tool which can be widely used in synaesthesia research to reveal the influence of individual differences on various performance measures and will be useful in generating new hypotheses.