987 resultados para Monitoring, Ambulatory


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study is to evaluate if hemodialysis (HD) patients with similar blood pressure (BP) in the whole inter-HD period could have different target organ lesions and survival if the behavior of BP differs from the first to the second day of the inter-HD period. The present study compares 44-hour ambulatory BP monitoring (ABPM) patterns in 45 HD patients. Three BP patterns emerged: group A (n = 15) had similar BPs throughout (138 ± 11/88 ± 12 in the first 22 h vs. 140 ± 11/87 ± 12 mm Hg in the second 22-hour period); group B (n = 15) had a significant systolic BP rise from the first to the second period (132 ± 15/80 ± 12 vs. 147 ± 12/86 ± 13 mm Hg, p < 0.05); group C (n = 15) had significantly higher BPs (p < 0.05) than the other 2 groups throughout the whole inter-HD period, with no significant change between the 2 halves (172 ± 14/108 ± 12 vs. 173 ± 18/109 ± 14 mm Hg). Ventricular mass and survival during the 30-month follow-up period were statistically significantly better in group A, intermediate in group B and worse in group C. The data suggest that a 44-hour ABPM is more accurate than a 24-hour one in evaluating organ lesion and prognosis in HD patients. Copyright © 2006 S. Karger AG.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Up to 60% of syncopal episodes remain unexplained. We report the results of a standardized, stepwise evaluation of patients referred to an ambulatory clinic for unexplained syncope. METHODS AND RESULTS: We studied 939 consecutive patients referred for unexplained syncope, who underwent a standardized evaluation, including history, physical examination, electrocardiogram, head-up tilt testing (HUTT), carotid sinus massage (CSM) and hyperventilation testing (HYV). Echocardiogram and stress test were performed when underlying heart disease was initially suspected. Electrophysiological study (EPS) and implantable loop recorder (ILR) were used only in patients with underlying structural heart disease or major unexplained syncope. We identified a cause of syncope in 66% of patients, including 27% vasovagal, 14% psychogenic, 6% arrhythmias, and 6% hypotension. Noninvasive testing identified 92% and invasive testing an additional 8% of the causes. HUTT yielded 38%, CSM 28%, HYV 49%, EPS 22%, and ILR 56% of diagnoses. On average, patients with arrhythmic causes were older, had a lower functional capacity, longer P-wave duration, and presented with fewer prodromes than patients with vasovagal or psychogenic syncope. CONCLUSIONS: A standardized stepwise evaluation emphasizing noninvasive tests yielded 2/3 of causes in patients referred to an ambulatory clinic for unexplained syncope. Neurally mediated and psychogenic mechanisms were behind >50% of episodes, while cardiac arrhythmias were uncommon. Sudden syncope, particularly in older patients with functional limitations or a prolonged P-wave, suggests an arrhythmic cause.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The use of electrocardiogram nowadays, is very important in diagnosis of heart disease. The emergent increase of portable technology provides medica] monitoring of vital signs allowing freedom ofmovement and watching during normal activity of the patient. In this shidy, it is described the development of a prototype of an ambulatory cardiac monitoring system using 3 leads. The systems consists on conversion of an analog signal, having been previously processed and conditioned, into digital ECG signal and after processed with a microcontroller (MCU). The heartbeat rate can be observed in an LCD display. The LCD display is also used as the interface during the setup process. Ali digital data stream can be stored on a SD memory card llowing the ECG signa] to be accessed later on a PC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Wearable monitors are increasingly being used to objectively monitor physical activity in research studies within the field of exercise science. Calibration and validation of these devices are vital to obtaining accurate data. This article is aimed primarily at the physical activity measurement specialist, although the end user who is conducting studies with these devices also may benefit from knowing about this topic. Best Practices Initially, wearable physical activity monitors should undergo unit calibration to ensure interinstrument reliability. The next step is to simultaneously collect both raw signal data (e.g., acceleration) from the wearable monitors and rates of energy expenditure, so that algorithms can be developed to convert the direct signals into energy expenditure. This process should use multiple wearable monitors and a large and diverse subject group and should include a wide range of physical activities commonly performed in daily life (from sedentary to vigorous). Future Directions New methods of calibration now use "pattern recognition" approaches to train the algorithms on various activities, and they provide estimates of energy expenditure that are much better than those previously available with the single-regression approach. Once a method of predicting energy expenditure has been established, the next step is to examine its predictive accuracy by cross-validating it in other populations. In this article, we attempt to summarize the best practices for calibration and validation of wearable physical activity monitors. Finally, we conclude with some ideas for future research ideas that will move the field of physical activity measurement forward.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. PURPOSE This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. METHODS A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and VO 2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). RESULTS Across all four intensity levels, the EV (κ = 0.68) and FT (κ = 0.66) cut points exhibited significantly better agreement than TR (κ = 0.62), MT (κ = 0.54), and PU (κ = 0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate-to vigorous-intensity physical activity (ROC-AUC = 0.90) than TR, PU, or MT cut points (ROC-AUC = 0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC = 0.90). CONCLUSIONS On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents. Copyright © 2011 by the American College of Sports Medicine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Most hypertensive patients need more than one drug to reach recommended blood-pressure targets. We investigated the effects on 24-h ambulatory blood pressure (ABP) of the angiotensin-receptor blocker, valsartan, in combination with hydrochlorothiazide (HCTZ), compared with the calcium-channel blocker amlodipine in a Brazilian population in a multicentre, double-blind, double-dummy, parallel group, controlled study in 373 patients with essential hypertension. After a 2-week washout period, patients with a mean sitting systolic blood pressure (SBP) of 160-190 mmHg were randomized to receive either valsartan 160 mg o.d., or amlodipine 5 mg o.d. for 2 weeks and subsequently force-titrated to valsartan 160 mg/HCTZ 25 mg o.d. or amlodipine 10 mg o.d. This regimen was continued until the end of the study at week 8. The primary efficacy parameter was the change from baseline to week 8 in mean 24-h SBP. Secondary endpoints were change in mean 24-h diastolic blood pressure (DBP), tolerability and safety of treatments. Valsartan/HCTZ achieved a mean reduction in systolic ABP of -19.1 ± 11.3 mmHg compared with -20.7 ± 12.0 mmHg with amlodipine (p = 0.324 for the comparison) and in diastolic ABP by -11.1 ± 7.4 mmHg vs -11.6 ± 7.2 mmHg by amlodipine (p = 0.853 for the comparison). The valsartan/HCTZ group exhibited markedly lower rates of adverse events and discontinuations than the amlodipine group. Peripheral oedemas were far more frequent with amlodipine than with valsartan/HCTZ (1.6% with valsartan/HCTZ; 16.8% with amlodipine). Thus, the valsartan 160 mg/HCTZ 25 mg combination appears to be as efficacious as amlodipine 10 mg in this patient population but better tolerated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction The objectives of this thesis are to: (1) examine how ambulatory blood pressure monitoring (ABPM) refines office blood pressure (BP) measurement; (2) determine if absolute ambulatory BP or dipping status is better associated with target organ damage (TOD); (3) explore the association of isolated nocturnal hypertension (INH) with TOD; and (4) investigate the association of night-time BP with ultrasound markers of cardiovascular damage. Methods Data from the Mitchelstown Cohort Study was analysed to deliver objectives 1 and 2. Objective 3 was addressed by a systematic review and analysis of data from the Mitchelstown Study. A sample of participants from the Mitchelstown Study underwent an echocardiogram for speckle tracking analysis and carotid ultrasound to achieve objective 4. Results ABPM reclassifies hypertension status in approximately a quarter of individuals, with white coat and masked hypertension prevalence rates of 11% and 13% respectively. Night-time systolic BP is better associated with TOD than daytime systolic BP and dipping level. In multi-variable models the odds ratio (OR) for LVH was 1.4 (95% CI 1.1 -1.8) and for albumin:creatinine ratio ≥ 1.1 mg/mmol was 1.5 (95% CI 1.2 – 1.8) for each 10 mmHg rise in night-time systolic BP. The evidence for the association of INH with TOD is inconclusive. Night-time systolic BP is significantly associated with global longitudinal strain (GLS) (beta coefficient 0.85 for every 10 mmHg rise, 95% CI 0.3 – 1.4) and carotid plaques (OR 1.9 for every 10 mmHg rise, 95% CI 1.1 – 3.2) in univariable analysis. The findings persist for GLS in sex and age adjusted models but not in multivariable models. Discussion Hypertension cannot be effectively managed without using ABPM. Night-time systolic BP is better associated with TOD than daytime systolic BP and dipping level, and therefore, may be a better therapeutic target in future studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Editorial: This theme issue of BJSM presents key papers from the 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement (ICAMPAM). The July 2013 conference was hosted by the University of Massachusetts and was attended by researchers, clinicians, students and technology vendors for North America, Europe, Australasia and Asia...

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper introduced a long-term ambulatory intragastric pH monitoring system, which is designed for prolonged ambulatory studies of Gastroesophageal Reflux Diseases. The whole system is composed of the gastric catheter with two pH sensors, a small data logger (Microdatalog), and a notebook PC. In this paper, the design of monitoring system hardware and software are described in detail. Clinical applications reveal good results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Twenty-four-hour pH monitoring is the 'gold standard' investigation of gastro-oesophageal reflux disease. It has been suggested that results may be influenced by lifestyle alteration during the study. The aim of this study was to determine the influence of lifestyle alteration and anxiety on outcome in pH monitoring.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ambulatory blood pressure profiles were obtained with the portable semi-automatic blood pressure recorder Remler M2000 in groups of 20 adolescents, 20 young and 20 middle-aged adults and 20 elderly untreated patients, all considered by their physician to be hypertensive. It was found that adolescents who are hypertensive when seeing their physician are more often normotensive outside the physician's office than adult and elderly patients under similar conditions. The increased heart rate variability which was detected in adolescents was not associated with an enhanced blood pressure variability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate the systemic blood pressure (BP) during daytime and nighttime in children with sleep breathing disorders (SBD) and compare parameters of BP in children with diagnosis of obstructive sleep apnea syndrome (OSA) to those one with primary snoring (PS).Methods: Children, both genders, aged from 8 to 12 years, with symptoms of SBD realized an overnight polysomnography followed by a 24 h recording of ambulatory BP.Results: All subjects presented with a history of snoring 7 nights per week. Children who have apnea/hipoapnea index >= four or a apnea index >= one presented a mean BP of 93 +/- 7 mmHg and 85 +/- 9 mmHg diurnal and nocturnal respectively whereas children who have a apnea/hipoapnea < four or a apnea index < one presented 90 +/- 7 mmHg and 77 +/- 2 mmHg. Eight children out of fourteen, from OSA group, lost the physiologic nocturnal dipping of the blood pressure. Among OSA children 57% were considered non-dippers. Two (16%) have presented absence of nocturnal dipping among children with primary snoring. The possibility of OSA children loosing physiologic blood pressure dipping was 6.66 higher than the possibilities of patients from PS group.Discussion: Our results indicate that children with sleep apnea syndrome exhibit a higher 24 h blood pressure when compared with those of primary snoring in form of decreased degree of nocturnal dipping and increased levels of diastolic and mean blood pressure, according to previous studies in literature. OSA in children seems to be associated to the development of hypertension or other cardiovascular disease. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate the systemic blood pressure (BP) during daytime and nighttime in children with sleep breathing disorders (SBD) and compare parameters of BP in children with diagnosis of obstructive sleep apnea syndrome (OSA) to those one with primary snoring (PS). Methods: Children, both genders, aged from 8 to 12 years, with symptoms of SBD realized an overnight polysomnography followed by a 24 h recording of ambulatory BP. Results: All subjects presented with a history of snoring 7 nights per week. Children who have apnea/hipoapnea index >= four or a apnea index >= one presented a mean BP of 93 +/- 7 mmHg and 85 +/- 9 mmHg diurnal and nocturnal respectively whereas children who have a apnea/hipoapnea < four or a apnea index < one presented 90 +/- 7 mmHg and 77 +/- 2 mmHg. Eight children out of fourteen, from OSA group, lost the physiologic nocturnal dipping of the blood pressure. Among OSA children 57% were considered non-dippers. Two (16%) have presented absence of nocturnal dipping among children with primary snoring. The possibility of OSA children loosing physiologic blood pressure dipping was 6.66 higher than the possibilities of patients from PS group. Discussion: Our results indicate that children with sleep apnea syndrome exhibit a higher 24 h blood pressure when compared with those of primary snoring in form of decreased degree of nocturnal dipping and increased levels of diastolic and mean blood pressure, according to previous studies in literature. OSA in children seems to be associated to the development of hypertension or other cardiovascular disease. (C) 2012 Elsevier Ireland Ltd. All rights reserved.