1000 resultados para Milking time
Resumo:
From January to October 1995, chloride content determinations were accomplished in 2,218 samples of milk collected from 67 quarters of 17 lactating cows, in initial, middle and final stages of lactation, in the morning and afternoon milking. The highest means of chloride contents were observed among the milk samples collected in the final stage of lactation (0,203 gC1/100ml), in the summer (0,212 gC1/100ml) and in the morning milking (0,189 g C1/100ml). The differences observed between the chloride contents in the samples obtained in the different stages of lactation and the seasons of the year were statistically significant (P<0.0001). The gratest occornce of chloride at rates superior to 0.22 gC1100ml was observed in the final stge of lactation (31.4%), summer (44.2%) and after the morning milking (27.8%). These results evidentiate the influence of physiological and external factors (stage of lactation and season of the year) on the concentration of chloride of milk.
Resumo:
To study the effects of a milking system that partially compensates for milk flow-dependent vacuum loss compared with a standard (high-line) milking unit in a tie-stall barn, milk flow and vacuum patterns were recorded in 10 cows during machine milking with 2 milking systems in a crossover design for 7 d each. Before and after each treatment period postmilking teat condition was recorded by ultrasound cross-sectioning. Additionally, 2 methods to measure teat tissue condition were compared: longitudinal teat ultrasound cross-sectioning and teat tissue density measurements with the spring-loaded caliper (cutimeter method). The partial compensation of milk flow-dependent vacuum loss caused an elevation of the peak flow rate (4.74+/-0.08 vs. 4.29+/-0.07 kg/min) and a shorter duration of plateau (1.57+/-0.06 vs. 1.96+/-0.07 min) compared with the standard milking system. Total milk yield, duration of incline and decline of milk flow, average milk flow, time until peak flow rate, main milking time, and total milking time did not differ between treatments (overall means: 13.75+/-0.17 kg; 0.65+/-0.01 min; 2.88+/-0.09 min; 2.82+/-0.05 kg/min; 1.65+/-0.03 min; 5.23+/-0.09 min, and 5.30+/-0.10 min, respectively). The vacuum drop in the short milk tube during periods of high milk flow was less in the compensating vacuum than in the standard milking system (11+/-1.1 vs. 15+/-0.7 kPa). Teat measures as determined by ultrasound remained unchanged over the entire experimental period with both milking systems. Postmilking teat tissue measures including their recovery within 20 min after the end of milking show a correlation (0.85 and 0.71, respectively) between the methods used (ultrasound and cutimeter method). In conclusion, a more constant vacuum at the teat tip (within the short milk tube) during periods of high milk flow affected milk flow patterns, mainly increasing peak flow rate. However, the reduced vacuum loss did not increase the overall speed of milking. In addition, effects of higher vacuum stability on teat condition and udder health were not obvious.
Resumo:
The goal of the present study was to examine the suitability of a short pre-stimulation (P) for 15 s followed by a latency period (L) of 30 s before cluster attachment for machine milking. In addition we tested the effect of a periodic reduction of the vacuum under the teat (VR) during the massage phase from 43 kPa to 12-15 kPa on milking characteristics and teat tissue condition. The study was carried out in 9 cows in a cross-over design. Animals were milked twice daily, and each of the 4 treatment combinations was used for six subsequent milkings (P+L vs. continuous P, and standard pulsation vs. VR, respectively). Milk flow was recorded during all experimental milkings. Longitudinal ultrasound cross sections of the teat were performed by B-mode ultrasound after the last milking of each treatment at 0, 5, and 15 min after the end of milking, respectively. None of the evaluated milking characteristics (total milk yield, main milking time, peak flow rate, average milk flow) differed between treatments. Teat measures as obtained by ultrasound cross sections showed no significant difference if individual treatments were compared at the three time points individually. However, teat wall thickness (TWT) tended to be smaller in VR vs. non-VR treatments at 5 min after milking (P=0·05). In conclusion, teat preparation consisting of a short stimulation followed by a latency period represents a similarly efficient pre-stimulation as a continuous pre-stimulation. VR seems to reduce the load on the teat tissue during milking and thus reduces the development of oedema and hence a less pronounced increase of TWT while milking characteristics are similar with or without VR.
Resumo:
The objective of this work was to evaluate the influence of pasture composition and regrowth age on the relationship between feeding behavior and ruminal fermentation in dairy cows grazing perennial ryegrass with or without white clover. The experiment was carried out in a 2x2 factorial arrangement, with two sward types and two ages of regrowth. Swards of perennial ryegrass sown alone (PRG) and of perennial ryegrass mixed with white clover (GC) were evaluated. Twelve late-lactation Holstein cows, fistulated at the rumen, were distributed in a 4x4 latin square experimental design with four 12-day periods. Daily distribution of grazing was similar in the PRG and the GC swards, but the concentration of rumen volatile fatty acids (VFA) was higher and the proportion of propionate was lower on mixed swards during the day. Daily distribution of grazing was similar in pastures of different ages. However, in the oldest swards, rumen fluid pH increased and VFA concentration decreased after evening milking. Time spent grazing does not influence ruminal fermentation, which depends on the changes that occur as different sward layers are grazed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
From January to October of 1995, somatic cell countings were accomplished in 2,218 milk samples collected from 67 quarters of 17 lactating cows at the initial, middle and final stages of lactation, in the morning and evening milkings. The highest means of cell countings were observed among the milk samples collected at the Final stage of lactation 15.652cell/ml), in the winter (5.358cell/ml) and the afternoon milking (5.199cell/ml). The differences observed amongst the cell countings in samples obtained at the different stages of lactation and the morning and afternoon milkings were statistically significant (P < 0.0001). In contrast differences observed amongst the seasons of the year, showed to be non-significant at the level of 5% probability. Higher occurrence of samples with cell countings superior to 500,000cell/ml was verified at the final stage of lactation (34.9%), in the winter (23.6%) and the afternoon milking (21.3%). These findings show the influence of physiologic and management factors (stage of Lactation and milking time) on milk cell concentrations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Experiments were designed to investigate the suitability of a combination of a short manual teat stimulation with a short latency period before teat cup attachment to induce and maintain oxytocin release and milk ejection without interruption. In Experiment 1, seven dairy cows in mid lactation were manually pre-stimulated for 15, 30 or 45 s, followed by either 30 s or 45 s of latency period. It was shown that all treatments induced a similar release of oxytocin without interruption until the end of milking. In particular, the latency period of up to 45 s did not cause a transient decrease of oxytocin concentration. In Experiment 2, milking characteristics were recorded in seven cows each in early, mid, and late lactation, respectively. Because the course of milk ejection depends mainly on the degree of udder filling, individual milkings were classified based on the actual degree of udder filling which differs between lactational stages but also between morning and evening milkings. All animals underwent twelve different udder preparation treatments, i.e. 15, 30, or 45 s of pre-stimulation followed by latency periods of 0, 30, 45, or 60 s. Milking characteristics were recorded. Total milk yield, main milking time and average milk flow rate did not differ between treatments if the degree of udder filling at the start of milking was >40% of the maximum storage capacity. However, if the udder filling was <40%, main milking time was decreased with the duration of a latency period up to 45 s, independent of duration of pre-stimulation. Average milk flow at an udder filling of <40% was highest after a pre-stimulation of 45 s followed by a latency period of another 45 s. In contrast, average milk flow reached its lowest values at a pre-stimulation of 15 s without additional latency period. However, average milk flow after a 15-s pre-stimulation increased with increasing latency period. In conclusion, a very short pre-stimulation when followed by a latency period up to 45 s before teat cup attachment remains a suitable alternative for continuous stimulation to induce milk ejection.
Resumo:
Cover title.
Resumo:
The aim of this paper was to evaluate the automated acclimatization effects during pre-milking of cows on thermal conditioning, physiology, milk production and cost-benefit of the automated adiabatic evaporative cooling system (AECS). The treatments 20; 30; 40 min and control consisted of exposure time of pre-milking cows to the automated AECS. Sixteen cows were used with an average daily milk yield of 19 kg, distributed in a 4 x 4 Latin square design. The Tukey's test (P<0.05) was used to compare the means. The environmental variables, dry bulb temperature (DBT, ºC) and relative humidity (RH, %), were recorded every minute, which allowed the determination of the system efficiency through the Temperature and Humidity Index (THI). The respiratory rate (RR), rectal temperature (RT) and temperature of the coat (TC) were measured before and after the acclimatization. The 40 min treatment kept the environmental variables and the comfort indexes within recommended limits. The physiological variables (RR, RT and TC) were lower in the 40 min treatment and reflected positively on milk production, which increased 3.66% compared to the control treatment. The system was profitable, having a 43 days return on investment and a monthly revenue increase of R$ 1,992.67.
Resumo:
Biofilms constitute a physical barrier, protecting the encased bacteria from detergents and sanitizers. The objective of this work was to analyze the effectiveness of sodium hypochlorite (NaOCl) against strains of Staphylococcus aureus isolated from raw milk of cows with subclinical mastitis and Staphylococcus aureus isolated from the milking environment (blowers and milk conducting tubes). The results revealed that, in the presence of NaOCl (150ppm), the number of adhered cells of the twelve S. aureus strains was significantly reduced. When the same strains were evaluated in biofilm condition, different results were obtained. It was found that, after a contact period of five minutes with NaOCl (150ppm), four strains (two strains from milk , one from the blowers and one from a conductive rubber) were still able to grow. Although with the increasing contact time between the bacteria and the NaOCl (150ppm), no growth was detected for any of the strains. Concerning the efficiency of NaOCl on total biofilm biomass formation by each S. aureus strain, a decrease was observed when these strains were in contact with 150 ppm NaOCl for a total period of 10 minutes. This study highlights the importance of a correct sanitation protocol of all the milk processing units which can indeed significantly reduce the presence of microorganisms, leading to a decrease of cow´s mastitis and milk contamination.
Resumo:
Dairy cows often have to choose which of two sides to enter in the milking parlour. Some cows are very consistent in this choicė, and it is common to assume that when these cows are more disturbed are being milked in their non-preferred side. Such disturbance might involve significantly poor welfare. In order to assess this assumption, we decided to study the behaviour and milk yield of dairy cows and their relationships with side preference in the milking parlour. The study was carried out at Cambridge University Farm, in a two-sided tandem milking parlour. The data collection followed the daily management routine. We recorded the side chosen by each cow (left or right) during 40 milking sessions. Data from 70 cows, which were present in at least 25 milking sessions (mode = 36), were included in the statistical analysis. Cows' reactivity (CR) during premilking udder preparation, time spent fitting the milking cluster (FT), milk yield (MY) and duration of milking (DM) were measured. There was evident individual variation in the consistency of side choice. Individual differences (ANOVA, P < 0.001) were also found in CR, FT, MY and DM; although these variables were not significantly affected by the side or the interaction animal × side (ANOVA, P < 0.05). The comparison between left and right side means (paired t-test) of these variables did not show significant differences (P < 0.05). We concluded that there is no evidence that the cows were discomforted or stressed when milked in the non-preferred side of the milking parlour. © 2001 Elsevier Science B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Milk cortisol concentration was determined under routine management conditions on 4 farms with an auto-tandem milking parlor and 8 farms with 1 of 2 automatic milking systems (AMS). One of the AMS was a partially forced (AMSp) system, and the other was a free cow traffic (AMSf) system. Milk samples were collected for all the cows on a given farm (20 to 54 cows) for at least 1 d. Behavioral observations were made during the milking process for a subset of 16 to 20 cows per farm. Milk cortisol concentration was evaluated by milking system, time of day, behavior during milking, daily milk yield, and somatic cell count using linear mixed-effects models. Milk cortisol did not differ between systems (AMSp: 1.15 +/- 0.07; AMSf: 1.02 +/- 0.12; auto-tandem parlor: 1.01 +/- 0.16 nmol/L). Cortisol concentrations were lower in evening than in morning milkings (1.01 +/- 0.12 vs. 1.24 +/- 0.13 nmol/L). The daily periodicity of cortisol concentration was characterized by an early morning peak and a late afternoon elevation in AMSp. A bimodal pattern was not evident in AMSf. Finally, milk cortisol decreased by a factor of 0.915 in milking parlors, by 0.998 in AMSp, and increased by a factor of 1.161 in AMSf for each unit of ln(somatic cell count/1,000). We conclude that milking cows in milking parlors or AMS does not result in relevant stress differences as measured by milk cortisol concentrations. The biological relevance of the difference regarding the daily periodicity of milk cortisol concentrations observed between the AMSp and AMSf needs further investigation.