994 resultados para Medical electronics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Item 215

Relevância:

30.00% 30.00%

Publicador:

Resumo:

My project is a business plan about the set up of a company and the development of a new and innovative product aimed for the elders. I decide do this project when I discover that one of the more important needs that have the elders is to remember the medicines that they have to take. I thought that a good way could be through a smart watch. My watch have an only function, is a cheap device, easy to use, easy to understand and easy to set up, because the elders usually do not know to use complex electronics devices. There are other similar smart watches and other devices but do not have the necessary characteristics to be a good reminder for elders. My watch is centred to improve the life of the elders, but my product could also be useful for ill people who have to take many medicines during the day. After realizing this business plan, I have proved that my company is viable in the environment and profitable in the market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A high-sample rate 3D median filtering processor architecture is proposed, based on a novel 3D median filtering algorithm, that can reduce the computing complexity in comparison with the traditional bubble sorting algorithm. A 3 x 3 x 3 filter processor is implemented in VHDL, and the simulation verifies that the processor can process a 128 x 128 x 96 MRI image in 0.03 seconds while running at 50 MHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wearable antenna performance measurements were used to characterize a synthetic variable layered phantom testbed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with measurements on the thorax region of a human test subject. The results show that the phantom is representative of the human body for the application of wireless vital sign monitors, where conductive connections are made to the tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of biosensors attached to the body for health monitoring is now readily accepted, and the merits of such systems and their potential impact on healthcare receive much attention. Wearable medical systems used in clinical applications to monitor vital signs must be comfortable to wear, yet have robust performance to ensure reliable communications links. Additionally, and vital to the success of these innovations, is that these solutions are disposable to avoid risk of patient infection and this means that they must be ultra-low cost. Antennas optimized for printing using conductive inks offer new exciting advances in making a truly disposable solution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A wearable silver nano particle inkjet printed antenna suitable for wireless biomedical sensing is presented. The performance is evaluated on a synthetic variable layered phantom test-bed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with antennas prototyped with copper. Total radiation efficiencies up to ???6.5 dB are reported, with less than 0.5 dB difference in performance between copper and silver nano particle variants, showing promising application for low-cost disposable wireless sensing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electronic waste is a fairly new and largely unknown phenomenon. Accordingly, governments have only recently acknowledged electronic waste as a threat to the environment and public health. In attempting to mitigate the hazards associated with this rapidly growing toxic waste stream, governments at all levels have started to implement e-waste management programs. The legislation enacted to create these programs is based on extended producer responsibility or EPR policy. ^ EPR shifts the burden of final disposal of e-waste from the consumer or municipal solid waste system to the manufacturer of electronic equipment. Applying an EPR policy is intended to send signals up the production chain to the manufacturer. The desired outcome is to change the methods of production in order to reduce production outputs/inputs with the ultimate goal of changing product design. This thesis performs a policy analysis of the current e-waste policies at the federal and state level of government, focusing specifically on Texas e-waste policies. ^ The Texas e-waste law known, as HB 2714 or the Texas Computer TakeBack Law, requires manufacturers to provide individual consumers with a free and convenient method for returning their used computers to manufacturers. The law is based on individual producer responsibility and shared responsibility among consumer, retailers, recyclers, and the TCEQ. ^ Using a set of evaluation criteria created by the Organization for Economic Co-operation and Development, the Texas e-waste law was examined to determine its effectiveness at reducing the threat of e-waste in Texas. Based on the outcomes of the analysis certain recommendations were made for the legislature to incorporate into HB 2714. ^ The results of the policy analysis show that HB 2714 is a poorly constructed law and does not provide the desired results seen in other states with EPR policies. The TakeBack Law does little to change the collection methods of manufacturers and even less to change their production habits. If the e-waste problem is to be taken seriously, HB 2714 must be amended to reflect the proposed changes in this thesis.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation is about the research carried on developing an MPS (Multipurpose Portable System) which consists of an instrument and many accessories. The instrument is portable, hand-held, and rechargeable battery operated, and it measures temperature, absorbance, and concentration of samples by using optical principles. The system also performs auxiliary functions like incubation and mixing. This system can be used in environmental, industrial, and medical applications. ^ Research emphasis is on system modularity, easy configuration, accuracy of measurements, power management schemes, reliability, low cost, computer interface, and networking. The instrument can send the data to a computer for data analysis and presentation, or to a printer. ^ This dissertation includes the presentation of a full working system. This involved integration of hardware and firmware for the micro-controller in assembly language, software in C and other application modules. ^ The instrument contains the Optics, Transimpedance Amplifiers, Voltage-to-Frequency Converters, LCD display, Lamp Driver, Battery Charger, Battery Manager, Timer, Interface Port, and Micro-controller. ^ The accessories are a Printer, Data Acquisition Adapter (to transfer the measurements to a computer via the Printer Port and expand the Analog/Digital conversion capability), Car Plug Adapter, and AC Transformer. This system has been fully evaluated for fault tolerance and the schemes will also be presented. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The primary goal of this dissertation is to develop point-based rigid and non-rigid image registration methods that have better accuracy than existing methods. We first present point-based PoIRe, which provides the framework for point-based global rigid registrations. It allows a choice of different search strategies including (a) branch-and-bound, (b) probabilistic hill-climbing, and (c) a novel hybrid method that takes advantage of the best characteristics of the other two methods. We use a robust similarity measure that is insensitive to noise, which is often introduced during feature extraction. We show the robustness of PoIRe using it to register images obtained with an electronic portal imaging device (EPID), which have large amounts of scatter and low contrast. To evaluate PoIRe we used (a) simulated images and (b) images with fiducial markers; PoIRe was extensively tested with 2D EPID images and images generated by 3D Computer Tomography (CT) and Magnetic Resonance (MR) images. PoIRe was also evaluated using benchmark data sets from the blind retrospective evaluation project (RIRE). We show that PoIRe is better than existing methods such as Iterative Closest Point (ICP) and methods based on mutual information. We also present a novel point-based local non-rigid shape registration algorithm. We extend the robust similarity measure used in PoIRe to non-rigid registrations adapting it to a free form deformation (FFD) model and making it robust to local minima, which is a drawback common to existing non-rigid point-based methods. For non-rigid registrations we show that it performs better than existing methods and that is less sensitive to starting conditions. We test our non-rigid registration method using available benchmark data sets for shape registration. Finally, we also explore the extraction of features invariant to changes in perspective and illumination, and explore how they can help improve the accuracy of multi-modal registration. For multimodal registration of EPID-DRR images we present a method based on a local descriptor defined by a vector of complex responses to a circular Gabor filter.