111 resultados para MICROSURGERY TEM
Resumo:
To describe a new suture technique for laryngeal microsurgery and to test its applicability in human cadaver larynges. The new technique was experimentally tested in freshly excised human larynges fixed to a larynx holder appropriate for the simulation of laryngeal microsurgery. A mucosal flap was created in the vocal fold for the fabrication of a pocket for subepithelial fat implantation, and the wound edges were then brought together and sutured using the proposed technique. The time necessary for suture was measured with a stopwatch for five successive sutures performed by one of the surgeons. The presence or absence of mucosal rupture was determined for five sutures performed by two surgeons, for a total of 10 sutures. The sutures were performed without the help of an assistant, with no laceration of the mucosa being observed in any of the attempts, and within a relatively short period of time even without previous training. The sutures performed permitted the implanted fat to remain stable under the mucosal flap. Conclusions: the new suture technique is an easy procedure, which can be performed by a single surgeon under microscopic vision, with a low risk of tissue rupture. The technique does not markedly prolong the duration of surgery and a single suture thread can be used for the fabrication of more than one stitch.
Resumo:
BACKGROUND: Transanal endoscopic microsurgery may represent appropriate diagnostic and therapeutic procedure in selected patients with distal rectal cancer following neoadjuvant chemoradiation. Even though this procedure has been associated with low rates of postoperative complications, patients undergoing neoadjuvant chemoradiation seem to be at increased risk for suture line dehiscence. In this setting, we compared the clinical outcomes of patients undergoing transanal endoscopic microsurgery with and without neoadjuvant chemoradiation. METHODS: Thirty-six consecutive patients were treated by transanal endoscopic microsurgery at a single institution. Twenty-three patients underwent local excision after neoadjuvant chemoradiation therapy for rectal adenocarcinoma, and 13 patients underwent local excision without any neoadjuvant treatment for benign and malignant rectal tumors. Chemoradiation therapy included 50.4 to 54Gy and 5-fluorouracil-based chemotherapy. All patients underwent transanal endoscopic microsurgery with primary closure of the rectal defect. Complications (immediate and late) and readmission rates were compared between groups. RESULTS: Overall, median hospital stay was 2 days. Immediate (30-d) complication rate was 44% for grade II/III complications. Patients undergoing neoadjuvant chemoradiation therapy were more likely to develop grade II/III immediate complications (56% vs 23%; P = .05). Overall, the 30-day readmission rate was 30%. Wound dehiscence was significantly more frequent among patients undergoing neoadjuvant chemoradiation therapy (70% vs 23%; P = .03). Patients undergoing neoadjuvant chemoradiation therapy were at significantly higher risk of requiring readmission (43% vs 7%; P = .02). CONCLUSION: Transanal local excision with the use of endoscopic microsurgical approach may result in significant postoperative morbidity, wound dehiscence, and readmission rates, in particular, because of rectal pain secondary to wound dehiscence. In this setting, the benefits of this minimally invasive approach either for diagnostic or therapeutic purposes become significantly restricted to highly selected patients that can potentially avoid a major operation but will still face a significantly morbid and painful procedure.
Resumo:
PURPOSE: Transanal endoscopic microsurgery provides a minimally invasive alternative to radical surgery for excision of benign and malignant rectal tumors. The purpose of this study was to review our experience with transanal endoscopic microsurgery to clarify its role in the treatment of different types of rectal pathology. METHODS: A prospective database documented all patients undergoing transanal endoscopic microsurgery from October 1996 through June 2008. We analyzed patient and operative factors, complications, and tumor recurrence. For recurrence analysis, we excluded patients with fewer than 6 months of follow-up, previous excisions, known metastases at initial presentation, and those who underwent immediate radical resection following transanal endoscopic microsurgery. RESULTS: Two hundred sixty-nine patients underwent transanal endoscopic microsurgery for benign (n = 158) and malignant (n = 111) tumors. Procedure-related complications (21%) included urinary retention (10.8%), fecal incontinence (4.1%), fever (3.8%), suture line dehiscence (1.5%), and bleeding (1.5%). Local recurrence rates for 121 benign and 83 malignant tumors were 5% for adenomas, 9.8% for T1 adenocarcinoma, 23.5% for T2 adenocarcinoma, 100% for T3 adenocarcinoma, and 0% for carcinoid tumors. All 6 (100%) recurrent adenomas were retreated with endoscopic techniques, and 8 of 17 (47%) recurrent adenocarcinomas underwent salvage procedures with curative intent. CONCLUSIONS: Transanal endoscopic microsurgery is a safe and effective method for excision of benign and malignant rectal tumors. Transanal endoscopic microsurgery can be offered for (1) curative resection of benign tumors, carcinoid tumors, and select T1 adenocarcinomas, (2) histopathologic staging in indeterminate cases, and (3) palliative resection in patients medically unfit or unwilling to undergo radical resection.
Resumo:
OBJECTIVE: To compare transanal endoscopic microsurgery (TEMS) with conventional transanal excision (TAE) in terms of the quality of resection, local recurrence, and survival rates in patients with stage I rectal cancer. BACKGROUND: Although TEMS is often considered a superior surgical technique to TAE, it is poorly suited for excising tumors in the lower third of the rectum. Such tumors may confer a worse prognosis. METHODS: We retrospectively reviewed information on all patients with stage pT1 and pT2 rectal adenocarcinoma who underwent local excision from 1997 through mid-2006. We excluded patients with node-positive, metastatic, recurrent, previously irradiated, or snare-excised tumors. RESULTS: Our study included 42 TEMS and 129 TAE patients. We found no significant differences in patient characteristics, adjuvant therapy, tumor stage, or adverse histopathologic features. In the TAE group, 52 (40%) of tumors were <5 cm from the anal verge (AV); in the TEMS group, only 1 (2%) (P = 0.0001). Surgical margins were less often positive in the TEMS group (2%) than in the TAE group (16%) (P = 0.017). For patients with tumors > or =5 cm from the AV, the estimated 5-year disease-free survival (DFS) rate was similar between the TEMS group (84.1%) and the TAE group (76.1%) (P = 0.651). But within the TAE group, the estimated 5-year DFS rate was better for patients with tumors > or =5 cm from the AV (76.1%) vs. <5 cm from the AV (60.5%) (P = 0.029). In our multivariate analysis, the tumor distance from the anal verge, the resection margin status, the T stage, and the use of adjuvant therapy--but not the surgical technique (i.e., TEMS or TAE) itself--were independent predictors of local recurrence and DFS. CONCLUSIONS: The quality of resection is better with TEMS than with TAE. However, the apparently better oncologic outcomes with TEMS can be partly explained by case selection of lower-risk tumors of the upper rectum.
Resumo:
OBJECTIVE: to describe a new model of training in microsurgery with pig spleen after splenectomy performed by undergraduate students of the Discipline of Operative Technique of the UFPR Medical School. METHODS: after the completion of splenectomy we performed dissection of the vascular pedicle, distal and proximal to the ligation performed for removal of the spleen. After complete dissection of the splenic artery and vein with microscope, clamps were placed and the vessels were cut. We then made the anastomosis of the vessels with 9.0 nylon. RESULT: the microsurgical training with a well-defined routine, qualified supervision and using low cost experimental materials proved to be effective in the practice of initial microvascular surgery. CONCLUSION: the use of pig spleen, which would be discarded after splenectomy, is an excellent model for microsurgical training, since besides having the consistency and sensitivity of a real model, it saves the sacrifice of a new animal model in the initial learning phase of this technique.
Resumo:
Postoperative pelvic abscesses in patients submitted to colorectal surgery are challenging. The surgical approach may be too risky, and image-guided drainage often is difficult due to the complex anatomy of the pelvis. This article describes novel access for drainage of a pelvic collection using a minimally invasive natural orifice approach. A 37 year-old man presented with sepsis due to a pelvic abscess during the second postoperative week after a Hartmann procedure due to perforated rectal cancer. Percutaneous drainage was determined by computed tomography to be unsuccessful, and another operation was considered to be hazardous. Because the pelvic fluid was very close to the rectal stump, transrectal drainage was planned. The rectal stump was opened using transanal endoscopic microsurgery (TEM) instruments. The endoscope was advanced through the TEM working channel and the rectal stump opening, accessing the abdominal cavity and pelvic collection. The pelvic collection was endoscopically drained and the local cavity washed with saline through the scope channel. A Foley catheter was placed in the rectal stump. The patient's recovery after the procedure was successful, without the need for further intervention. Transrectal endoscopic drainage may be an option for selected cases of pelvic fluid collection in patients submitted to Hartmann's procedure. The technique allows not only fluid drainage but also visualization of the local cavity, cleavage of multiloculated abscesses, and saline irrigation if necessary. The use of TEM instrumentation allows safe access to the peritoneal cavity.
Resumo:
Tumors involving bone and soft tissues are extremely challenging situations. With the recent advances of multi-modal treatment, not only the type of surgery has moved from amputation to limb-sparing procedures, but also the survivorship has improved considerably and reconstructive techniques have the goal to allow a considerably higher quality of life. In bone reconstruction, tissue engineering strategies are the main area of research. Re-vascularization and re-vitalisation of a massive allograft would considerably improve the outcome of biological reconstructions. Using a rabbit animal model, in this study we showed that, by implanting a vascular pedicle inside a weight bearing massive cortical allograft, the bone regeneration inside the allograft was higher compared to the non-vascularized implants, given the patency of the vascular pedicle. Improvement in the animal model and the addition of Stem Cells and Growth factors will allow a further improvement in the results. In soft tissue tumors, free and pedicled flaps have been proven to be of great help as reconstruction strategies. In this study we analyzed the functional and overall outcome of 14 patients who received a re-innervated vascularized flap. We have demonstrated that the use of the innovative technique of motor re-innervated muscular flaps is effective when the resection involves important functional compartments of the upper or lower limb, with no increase of post-operative complications. Although there was no direct comparison between this type of reconstruction and the standard non-innervated reconstruction, we underlined the remarkable high overall functional scores and patient satisfaction following this procedure.
Resumo:
Concerns of rising healthcare costs and the ever increasing desire to improve surgical outcome have motivated the development of a new robotic assisted surgical procedure for the implantation of artificial hearing devices (AHDs). This paper describes our efforts to enable minimally invasive, cost effective surgery for the implantation of AHDs. We approach this problem with a fundamental goal to reduce errors from every component of the surgical workflow from imaging and trajectory planning to patient tracking and robot development. These efforts were successful in reducing overall system error to a previously unattained level.
Resumo:
The delicate anatomy of the ear require surgeons to use great care when operating on its internal structures. One example for such an intervention is the stapedectomy, where a small crook shaped piston is placed in the oval window of the cochlea and connected to the incus through crimping thus bypassing the diseased stapes. Performing the crimp process with the correct force is necessary since loose crimps poorly transmit sound whereas tight crimps will eventually result in necrosis of the incus. Clinically, demand is high to reproducibly conduct the crimp process through a precise force measurement. For this reason, we have developed a fiber Bragg grating (FBG) integrated microforceps for use in such interventions. This device was calibrated, and tested in cadaver preparations. With this instrument we were able to measure for the first time forces involved in crimping a stapes prosthesis to the incus. We also discuss a method of attaching and actuating such forceps in conjunction with a robot currently under development in our group. Each component of this system can be used separately or combined to improve surgical accuracy, confidence and outcome.
Resumo:
The use of an operating microscope in animal liver surgery has made it possible to obtain new experimental models. The goal of this prospective animal study is to present our experience with dogfish portocaval microanastomoses.
Resumo:
Apical surgery is an important treatment option for teeth with post-treatment apical periodontitis. Knowledge of the long-term prognosis is necessary when weighing apical surgery against alternative treatments. This study assessed the 5-year outcome of apical surgery and its predictors in a cohort for which the 1-year outcome was previously reported.
Resumo:
Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.
Resumo:
Experiments using animal models are the most common way to learn microsurgery. This expertise is necessary for liver research, microsurgical reconstruction of the esophagus by free jejunum or reconstruction of the hepatic artery during reimplantation from living donors. The goal of this prospective study is to assess the reliability of an invertebrate model for microsurgical training.
Resumo:
The management of patients with small, often asymptomatic meningiomas is controversial and includes observation, microsurgery (MS) and stereotactic radiosurgery (SRS). The purpose of this retrospective study was to analyze the morbidity and the extent of removal after MS for small (< or =3 cm) intracranial meningiomas and compare these results to those of SRS reported in the literature.
Resumo:
A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3 %), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43 %) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.