924 resultados para Ionosphere parameters
Resumo:
In the paper we discuss the potential of the new Galileo signals for pseudorange based surveying and mapping in open areas under optimal reception conditions (open sky scenarios) and suboptimal ones (multipath created by moderate to thick tree coverage). The paper reviews the main features of the Galileo E5 AltBOC and E1 CBOC signals; describes the simulation strategy, models and algorithms to generate realistic E5 and E1 pseudoranges with and without multipath sources; describes the ionosphere modeling strategy, models and algorithms and discusses and presents the expected positioning accuracy and precision results. According to the simulations performed, pseudoranges can be extracted from the Galileo E5 AltBOC signals with tracking errors (1-σ level) ranging from 0.02 m (open sky scenarios) to 0.08 m (tree covered scenarios) whereas for the Galileo E1 CBOC signals the tracking errors range between 0.25 m to 2.00 m respectively. With these tracking errors and with the explicit estimation of the ionosphere parameters, simulations indicate real-time open sky cm-level horizontal positioning precisions and dm-level vertical ones and dm-level accuracies for both the horizontal and vertical position components.
Resumo:
Atmospheric surface boundary layer parameters vary anomalously in response to the occurrence of annular solar eclipse on 15th January 2010 over Cochin. It was the longest annular solar eclipse occurred over South India with high intensity. As it occurred during the noon hours, it is considered to be much more significant because of its effects in all the regions of atmosphere including ionosphere. Since the insolation is the main driving factor responsible for the anomalous changes occurred in the surface layer due to annular solar eclipse, occurred on 15th January 2010, that played very important role in understanding dynamics of the atmosphere during the eclipse period because of its coincidence with the noon time. The Sonic anemometer is able to give data of zonal, meridional and vertical wind as well as the air temperature at a temporal resolution of 1 s. Different surface boundary layer parameters and turbulent fluxes were computed by the application of eddy correlation technique using the high resolution station data. The surface boundary layer parameters that are computed using the sonic anemometer data during the period are momentum flux, sensible heat flux, turbulent kinetic energy, frictional velocity (u*), variance of temperature, variances of u, v and w wind. In order to compare the results, a control run has been done using the data of previous day as well as next day. It is noted that over the specified time period of annular solar eclipse, all the above stated surface boundary layer parameters vary anomalously when compared with the control run. From the observations we could note that momentum flux was 0.1 Nm 2 instead of the mean value 0.2 Nm-2 when there was eclipse. Sensible heat flux anomalously decreases to 50 Nm 2 instead of the mean value 200 Nm 2 at the time of solar eclipse. The turbulent kinetic energy decreases to 0.2 m2s 2 from the mean value 1 m2s 2. The frictional velocity value decreases to 0.05 ms 1 instead of the mean value 0.2 ms 1. The present study aimed at understanding the dynamics of surface layer in response to the annular solar eclipse over a tropical coastal station, occurred during the noon hours. Key words: annular solar eclipse, surface boundary layer, sonic anemometer
Resumo:
We propose a mechanism to explain suggested links between seismic activity and ionospheric changes detected overhead. Specifically, we explain changes in the natural extremely low-frequency (ELF) radio noise recently observed in the topside ionosphere aboard the DEMETER satellite at night, before major earthquakes. Our mechanism utilises increased electrical conductivity of surface layer air before a major earthquake, which reduces the surface-ionosphere electrical resistance. This increases the vertical fair weather current, and (to maintain continuity of electron flow) lowers the ionosphere. Magnitudes of crucial parameters are estimated and found to be consistent with observations. Natural variability in ionospheric and atmospheric electrical properties is evaluated, and may be overcome using a hybrid detection approach. Suggested experiments to investigate the mechanism involve measuring the cut-off frequency of ELF “tweeks”, the amplitude and phase of very low frequency radio waves in the Earth–ionosphere waveguide, or medium frequency radar, incoherent scatter or rocket studies of the lower ionospheric electron density.
Resumo:
Large upward field-aligned ion flows have previously been observed in the high latitude ionosphere in response to frictional heating of the local ion population. Results from a recent experiment using the EISCAT radar show similar features but allow, for the first time, determination of the field-aligned profiles of plasma parameters during these events. The upflows occur during frictional heating. The flows are shown to be transient plasma upwellings, from regions where the ion temperature has been elevated by the motion of a convection shear over the observed field line.
Resumo:
This paper surveys the results of simultaneous observations by the EISCAT incoherent scatter radar and the AMPTE-UKS satellite, made during three periods in September and October 1984, when AMPTE-UKS was in the solar wind on the dayside of the Earth and the UK-POLAR EISCAT experiment was measuring ionospheric parameters at invariant latitudes 70.8–75.0°. A total of 42 h of EISCAT convection velocity data, with 2.5 min resolution, were obtained, together with 28 h of simultaneous 5 s resolution AMPTE-UKS observations of the solar wind and interplanetary magnetic field (IMF). The general features of the AMPTE-UKS data are described in Section 2 and those of the EISCAT data are described in Sections 3 and 4. The main subjects discussed are the form of the plasma convection patterns and their dependence on all three components of the IMF (Section 5), the ionospheric response to abrupt changes in the IMF (Section 6), in particular a sharp ‘southward turning’ of the IMF on 27 October 1984, and a crossing of an IMF sector boundary. Section 7 describes ‘short lived rapid flow burst’, which are believed to be related to flux transfer events at the magnetopause.
Resumo:
Following a brief description of the atmosphere and ionosphere in Chapter I we describe how the equations of continuity and momentum for 0+, H+, He+, 0++ are derived from the formulations of St-Maurice and Schunk(1977) and Quegan et al.(1981) in Chapter II. In Chapter III we investigate the nature of the downward flow of protons in a collapsing post-sunset ionosphere. We derive an analytical form for the limiting temperature, we also note the importance of the polarization field term and concluded that the flow will remain subsonic for realistic conditions. The time-dependent behaviour of He+ under sunspot minimum conditions is investigated in Chapter IV. This is achieved by numerical solution of the 0+, H+ and,He+ continuity and momentum equations, treating He+ as a minor ion with 0+ , H+ as major ions. We found that He+ flows upwards during the day-time and downwards during the nighttime. He+ flux tube content reached a maximum on the 8th day of the integration period and started to decreasing. This is due to the large amount of H+ present at the late stages of the integration period which makes He+ unable to diffuse through the H+ layer away from the loss region. In Chapter V we investigate the behaviour of 0++ using sunspot maximum parameters. Although our results support the findings of Geis and Young (1981) that the large amounts of 0++ at the equator are caused mainly by thermal diffusion, the model used by Geis and Young overemphesizes the effect of thermal diffusion. The importance of 0++ - 0+ collision frequency is also noted. In Chapter VI we extend the work of Chapter IV, presenting a comparative study of H and He at sunspot minimum and sunspot maximum.In this last Chapter all three ions, O+ ,H+ and He+ , are treated theoretically as major ions and we concentrate mainly on light ion contents and fluxes. The results of this Chapter indicate that by assuming He+ as a minor ion we under-estimate He+ and over-estimate. H+. Some interesting features concerning the day to day behaviour of the light ion fluxes arise. In particular the day-time H+ fluxes decrease from day to day in contrast to the work of Murphy et al.(1976). In appendix.A we derive some analytical forms for the optical depth so that the models can include a realistic description of photoionization.
Resumo:
Frailty and anemia in the elderly appear to share a common pathophysiology associated with chronic inflammatory processes. This study uses an analytical, cross-sectional, population-based methodology to investigate the probable relationships between frailty, red blood cell parameters and inflammatory markers in 255 community-dwelling elders aged 65 years or older. The frailty phenotype was assessed by non-intentional weight loss, fatigue, low grip strength, low energy expenditure and reduced gait speed. Blood sample analyses were performed to determine hemoglobin level, hematocrit and reticulocyte count, as well as the inflammatory variables IL-6, IL-1ra and hsCRP. In the first multivariate analysis (model I), considering only the erythroid parameters, Hb concentration was a significant variable for both general frailty status and weight loss: a 1.0g/dL drop in serum Hb concentration represented a 2.02-fold increase (CI 1.12-3.63) in an individual's chance of being frail. In the second analysis (model II), which also included inflammatory cytokine levels, hsCRP was independently selected as a significant variable. Each additional year of age represented a 1.21-fold increase in the chance of being frail, and each 1-unit increase in serum hsCRP represented a 3.64-fold increase in the chance of having the frailty phenotype. In model II reticulocyte counts were associated with weight loss and reduced metabolic expenditure criteria. Our findings suggest that reduced Hb concentration, reduced RetAbs count and elevated serum hsCRP levels should be considered components of frailty, which in turn is correlated with sarcopenia, as evidenced by weight loss.
Resumo:
Bariatric surgery is considered an effective method for sustained weight loss, but may cause various nutritional complications. The aim of this study was to evaluate the nutritional status of minerals and vitamins, food consumption, and to monitor physiologic parameters in patients with obesity before and 6 months after Roux-en-Y gastric bypass surgery (RYGB). Thirty-six patients who had undergone RYGB were prospectively evaluated before and 6 months after surgery. At each phase their weight, height, body mass index (BMI), Electro Sensor Complex (ES Complex) data, food consumption, and total protein serum levels, albumin, prealbumin, parathyroid hormone (PTH), zinc (Zn), B12 vitamin (VitB12), iron (Fe), ferritin, copper (Cu), ionic calcium (CaI), magnesium (Mg), and folic acid were assessed. The mean weight loss from baseline to 6 months after surgery was 35.34±4.82%. Markers of autonomic nervous system balance (P<.01), stiffness index (P<.01), standard deviation of normal-to-normal R-R intervals (SDNN) (P<.01), and insulin resistance (P<.001) were also improved. With regard to the micronutrients measured, 34 patients demonstrated some kind of deficiency. There was a high percentage of Zn deficiency in both pre- (55.55%) and postoperative (61.11%) patients, and 33.33% of the patients were deficient in prealbumin postoperatively. The protein intake after 6 months of surgery was below the recommended intake (<70 g/d) for 88.88% of the patients. Laboratory analyses demonstrated an average decrease in total protein (P<.05), prealbumin (P = .002), and PTH (P = .008) between pre- and postsurgery, and a decrease in the percentage of deficiencies for Mg (P<.05), CaI (P<.05), and Fe (P = .021). Despite improvements in the autonomic nervous system balance, stiffness index markers and insulin resistance, we found a high prevalence of hypozincemia at 6 months post-RYGB. Furthermore, protein supplements were needed to maintain an adequate protein intake up to 6 months postsurgery.
Resumo:
Crotamine is one of the main constituents of the venom of the South American rattlesnake Crotalus durissus terrificus. Here we sought to investigate the inflammatory and toxicological effects induced by the intrahippocampal administration of crotamine isolated from Crotalus whole venom. Adult rats received an intrahippocampal infusion of crotamine or vehicle and were euthanized 24 h or 21 days after infusion. Plasma and brain tissue were collected for biochemical analysis. Complete blood count, creatinine, urea, glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), creatine-kinase (CK), creatine kinase-muscle B (CK-MB) and oxidative parameters (assessed by DNA damage and micronucleus frequency in leukocytes, lipid peroxidation and protein carbonyls in plasma and brain) were quantified. Unpaired and paired t-tests were used for comparisons between saline and crotamine groups, and within groups (24 h vs. 21 days), respectively. After 24 h crotamine infusion promoted an increase of urea, GOT, GPT, CK, and platelets values (p ≤ 0.01), while red blood cells, hematocrit and leukocytes values decreased (p ≤ 0.01). Additionally, 21 days after infusion crotamine group showed increased creatinine, leukocytes, TBARS (plasma and brain), carbonyl (plasma and brain) and micronucleus compared to the saline-group (p ≤ 0.01). Our findings show that crotamine infusion alter hematological parameters and cardiac markers, as well as oxidative parameters, not only in the brain, but also in the blood, indicating a systemic pro-inflammatory and toxicological activity. A further scientific attempt in terms of preserving the beneficial activity over toxicity is required.
Resumo:
The purpose of this study was to evaluate the effectiveness of mature red cell and reticulocyte parameters under three conditions: iron deficiency anemia, anemia of chronic disease, and anemia of chronic disease associated with absolute iron deficiency. Peripheral blood cells from 117 adult patients with anemia were classified according to iron status, and inflammatory activity, and the results of a hemoglobinopathy investigation as: iron deficiency anemia (n=42), anemia of chronic disease (n=28), anemia of chronic disease associated with iron deficiency anemia (n=22), and heterozygous β thalassemia (n=25). The percentage of microcytic red cells, hypochromic red cells, and levels of hemoglobin content in both reticulocytes and mature red cells were determined. Receiver operating characteristic analysis was used to evaluate the accuracy of the parameters in differentiating between the different types of anemia. There was no significant difference between the iron deficient group and anemia of chronic disease associated with absolute iron deficiency in respect to any parameter. The percentage of hypochromic red cells was the best parameter to discriminate anemia of chronic disease with and without absolute iron deficiency (area under curve=0.785; 95% confidence interval: 0.661-0.909, with sensitivity of 72.7%, and specificity of 70.4%; cut-off value 1.8%). The formula microcytic red cells minus hypochromic red cells was very accurate in differentiating iron deficiency anemia and heterozygous β thalassemia (area under curve=0.977; 95% confidence interval: 0.950-1.005; with sensitivity of 96.2%, and specificity of 92.7%; cut-off value 13.8). The indices related to red cells and reticulocytes have a moderate performance in identifying absolute iron deficiency in patients with anemia of chronic disease.
Resumo:
The main aim of this investigation was to verify the relationship of the variables measured during a 3-minute all-out test with aerobic (i.e., peak oxygen uptake [(Equation is included in full-text article.)] and intensity corresponding to the lactate minimum [LMI]) and anaerobic parameters (i.e., anaerobic work) measured during a 400-m maximal performance. To measure force continually and to avoid the possible influences caused by turns, the 3-minute all-out effort was performed in tethered swimming. Thirty swimmers performed the following tests: (a) a 3-minute all-out tethered swimming test to determine the final force (equivalent to critical force: CF3-MIN) and the work performed above CF3-MIN (W'3-MIN), (b) a LMI protocol to determine the LMI during front crawl swimming, and (c) a 400-m maximal test to determine the (Equation is included in full-text article.)and total anaerobic contribution (WANA). Correlations between the variables were tested using the Pearson's correlation test (p ≤ 0.05). CF3-MIN (73.9 ± 13.2 N) presented a high correlation with the LMI (1.33 ± 0.08 m·s; p = 0.01) and (Equation is included in full-text article.)(4.5 ± 1.2 L·min; p = 0.01). However, the W'3-MIN (1,943.2 ± 719.2 N·s) was only moderately correlated with LMI (p = 0.02) and (Equation is included in full-text article.)(p = 0.01). In summary, CF3-MIN determined during the 3-minute all-out effort is associated with oxidative metabolism and can be used to estimate the aerobic capacity of swimmers. In contrast, the anaerobic component of this model (W'3-MIN) is not correlated with WANA.
Resumo:
Current data indicate that the size of high-density lipoprotein (HDL) may be considered an important marker for cardiovascular disease risk. We established reference values of mean HDL size and volume in an asymptomatic representative Brazilian population sample (n=590) and their associations with metabolic parameters by gender. Size and volume were determined in HDL isolated from plasma by polyethyleneglycol precipitation of apoB-containing lipoproteins and measured using the dynamic light scattering (DLS) technique. Although the gender and age distributions agreed with other studies, the mean HDL size reference value was slightly lower than in some other populations. Both HDL size and volume were influenced by gender and varied according to age. HDL size was associated with age and HDL-C (total population); non- white ethnicity and CETP inversely (females); HDL-C and PLTP mass (males). On the other hand, HDL volume was determined only by HDL-C (total population and in both genders) and by PLTP mass (males). The reference values for mean HDL size and volume using the DLS technique were established in an asymptomatic and representative Brazilian population sample, as well as their related metabolic factors. HDL-C was a major determinant of HDL size and volume, which were differently modulated in females and in males.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física