51 resultados para ILLUMINANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall objective of this work is to provide diffuse illuminance availability at Madrid (Spain) through a statistical analysis of illuminance values corresponding to a long-term data series. The illuminance values are obtained from irradiance measurements by means of different empirical models for luminous efficacy. The values of diffuse illuminance on a horizontal and on vertical surfaces facing the four cardinal points are estimated and the different aspects related to daylight availability in an area with specific climatic conditions are analyzed. The experimental data consist of global and diffuse irradiance measurements on a horizontal surface provided by the National Meteorological Agency in Spain (AEMET) for Madrid. These data consist of hourly values measured in the period of 1980–2005. The statistical results derived correspond to a daylight typical year for the five surfaces considered. This information will be useful to building experts to estimate natural illumination availability when daylighting techniques are applied in building design with the main aim of electric energy savings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since industrialization and the formation of larger urban centers in the nineteenth century, pollution of the environment was always present in daily life in various ways, namely in the form of light. Light pollution can cause various consequences, both for humans and for their ecosystem, producing effects on environmental, social, economic and scientific level. In Portugal, the lighting is responsible for 3% of total electricity consumption, energy costs are in some cases more than 50% towards the costs incurred by municipalities with energy, checking-in recent years a trend similar to that improvement of illumination levels in the region (about 4 to 5% per year). Proper use of lighting brings many benefits both to the citizen and environment, since greater energy efficiency can contribute to reducing CO2 emissions, energy costs, as well as to decrease the use of resources not-renewable and/or contamination of renewable resources, which can occurs in the process of obtaining electricity. The present study has a main goal to analyze the illuminance levels associated to the public lighting of the village of Vialonga, Vila Franca de Xira (Portugal), to verify if it is efficient. The aim is also to relate the efficiency of street lighting with the existence of light pollution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface characteristics represent a critical issue facing pavement owners and the concrete paving industry. The traveling public has come to expect smoother, quieter, and better drained pavements, all without compromising safety. The overall surface characteristics issues is extremely complex since all pavement surface characteristics properties, including texture, noise, friction, splash/spray, rolling resistance, reflectivity/illuminance, and smoothness, are complexly related. The following needs and gaps related to achieving desired pavement surface characteristics need to be addressed: determined how changes in one surface characteristic affect, either beneficially or detrimentally, other characteristics of the pavement, determine the long-term surface and acoustic durability of different textures, and develop, evaluate, and standardize new data collection and analysis tools. It is clear that an overall strategic and coordinated research approach to the problem must be developed and pursued to address these needs and gaps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Phase II project follows a previous project titled Strategies to Address Nighttime Crashes at Rural, Unsignalized Intersections. Based on the results of the previous study, the Iowa Highway Research Board (IHRB) indicated interest in pursuing further research to address the quality of lighting, rather than just the presence of light, with respect to safety. The research team supplemented the literature review from the previous study, specifically addressing lighting level in terms of measurement, the relationship between light levels and safety, and lamp durability and efficiency. The Center for Transportation Research and Education (CTRE) teamed with a national research leader in roadway lighting, Virginia Tech Transportation Institute (VTTI) to collect the data. An integral instrument to the data collection efforts was the creation of the Roadway Monitoring System (RMS). The RMS allowed the research team to collect lighting data and approach information for each rural intersection identified in the previous phase. After data cleanup, the final data set contained illuminance data for 101 lighted intersections (of 137 lighted intersections in the first study). Data analysis included a robust statistical analysis based on Bayesian techniques. Average illuminance, average glare, and average uniformity ratio values were used to classify quality of lighting at the intersections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This Phase II project follows a previous project titled Strategies to Address Nighttime Crashes at Rural, Unsignalized Intersections. Based on the results of the previous study, the Iowa Highway Research Board (IHRB) indicated interest in pursuing further research to address the quality of lighting, rather than just the presence of light, with respect to safety. The research team supplemented the literature review from the previous study, specifically addressing lighting level in terms of measurement, the relationship between light levels and safety, and lamp durability and efficiency. The Center for Transportation Research and Education (CTRE) teamed with a national research leader in roadway lighting, Virginia Tech Transportation Institute (VTTI) to collect the data. An integral instrument to the data collection efforts was the creation of the Roadway Monitoring System (RMS). The RMS allowed the research team to collect lighting data and approach information for each rural intersection identified in the previous phase. After data cleanup, the final data set contained illuminance data for 101 lighted intersections (of 137 lighted intersections in the first study). Data analysis included a robust statistical analysis based on Bayesian techniques. Average illuminance, average glare, and average uniformity ratio values were used to classify quality of lighting at the intersections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Luonnonvarojen ehtyminen ja ympäristön saastuminen on luonut kysyntää uusille, energiaa säästäville ja ympäristöystävällisille teknologioille. Valaistuksessa tällainen teknologia on led-tekniikka. Led-tekniikalla on useita etuja verrattuna kilpaileviin tekniikoihin kuten pitkä elinikä, ympäristöystävällisyys ja mekaaninen kestävyys. Ledejä käytetään nykyään laajalti erilaisissa erikoissovelluksissa, erityisesti jos vaatimuksena on valon värillisyys. Näihin päiviin asti ledien hinta ja heikko valontuotto ovat rajoittaneet led-valaisimien yleistymistä hehkulamppujen ja muiden valaisintyyppien korvaajina. Tekniikan nopea kehittyminen on tehnyt led-tekniikasta varteenotettavan vaihtoehdon myös yleisvalaistukseen. Uusimpien valkoisten ledien valotehokkuus on 2 - 5 -kertainen hehkulamppuun verrattuna. Led-tekniikassa on vielä paljon käyttämätöntä potentiaalia, tulevaisuudessa päästäneen 10 - 15 -kertaiseen valotehokkuuteen hehkulamppuun verrattuna. Työssä suunnitellaan mikrokontrolleripohjainen ohjausjärjestelmä valkoista valoa tuottavalle led-valaisimelle, jonka värisävyä ja kirkkautta käyttäjä voi säätää. Valkoinen valo synnytetään sekoittamalla neljän erivärisen led-rivin valoa. Mikrokontrolleri ohjaa kutakin led-riviä väriensekoitusteoriaan perustuen. Mikrokontrolleriohjaus huomioi myös ledien optisten ominaisuuksien muutokset lämpötilan suhteen. Mikrokontrolleriohjauksen suorituskyky todetaan käytännön mittauksilla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diabetes is a rapidly increasing worldwide problem which is characterised by defective metabolism of glucose that causes long-term dysfunction and failure of various organs. The most common complication of diabetes is diabetic retinopathy (DR), which is one of the primary causes of blindness and visual impairment in adults. The rapid increase of diabetes pushes the limits of the current DR screening capabilities for which the digital imaging of the eye fundus (retinal imaging), and automatic or semi-automatic image analysis algorithms provide a potential solution. In this work, the use of colour in the detection of diabetic retinopathy is statistically studied using a supervised algorithm based on one-class classification and Gaussian mixture model estimation. The presented algorithm distinguishes a certain diabetic lesion type from all other possible objects in eye fundus images by only estimating the probability density function of that certain lesion type. For the training and ground truth estimation, the algorithm combines manual annotations of several experts for which the best practices were experimentally selected. By assessing the algorithm’s performance while conducting experiments with the colour space selection, both illuminance and colour correction, and background class information, the use of colour in the detection of diabetic retinopathy was quantitatively evaluated. Another contribution of this work is the benchmarking framework for eye fundus image analysis algorithms needed for the development of the automatic DR detection algorithms. The benchmarking framework provides guidelines on how to construct a benchmarking database that comprises true patient images, ground truth, and an evaluation protocol. The evaluation is based on the standard receiver operating characteristics analysis and it follows the medical practice in the decision making providing protocols for image- and pixel-based evaluations. During the work, two public medical image databases with ground truth were published: DIARETDB0 and DIARETDB1. The framework, DR databases and the final algorithm, are made public in the web to set the baseline results for automatic detection of diabetic retinopathy. Although deviating from the general context of the thesis, a simple and effective optic disc localisation method is presented. The optic disc localisation is discussed, since normal eye fundus structures are fundamental in the characterisation of DR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The spatial distribution of illuminance and the electric consumption of artificial lighting system is one of the main problems related to broiler production. Therefore, the aim of this study was to evaluate the spatial distribution of luminance level and energy efficiency of different lighting systems for broiler houses. Six types of lamps were tested in two different configurations to find the minimum illuminance of 20 and 5 lux. The tested lamps were incandescent (IL) 100 W, compact fluorescent (CFL) 34 W, mixed (ML) 160 W, sodium vapor (SVL) 70 W, T8 fluorescent tube (T8 FTL) 40 W and T5 fluorescent tube (T5 FTL) 28 W. The first four were evaluated with and without reflective light fixture and the latter two without light fixture. It was observed that the tested system with light fixtures negatively affected the spatial distribution of illuminance inside the house. The systems composed by IL and ML without light fixture led to better results in meeting the minimum illuminance of 20 lux and 5 lux, respectively. T5 FTL presented the lowest energy demand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT Broiler poultry is highly dependent on artificial lightening. Power consumption costs of artificial lighting systems is the second largest expense related to broiler industry, second only to feed expenses. Therefore, the current study focused to analyze technical and economic feasibility of replacing incandescent lamps already used in aviaries with other lamp types. Costs related to power consumption, implementation and maintenance of the lighting systems were evaluated with the aid of financial mathematics using net present value, return over investment and payback. Systems composed of six lamp types were analyzed in two different configurations to meet the minimum illuminance of 5 and 20 lux and for use in conventional sheds and dark house. The lamps tested were incandescent (LI) of 100 W, compact fluorescent (CFL) of 34 W, mixed (ML) 160 W sodium vapor (SVL) of 70 W, tubular fluorescent T8 (TFL T8) of 40 W and tubular fluorescent T5 (TFL T5) of 28 W. For the systems tested, it was found that the tubular fluorescent lamps T8 and T5 showed the best results of technical and economic feasibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

1. Shaver White and ISA Brown pullets were reared to 140 d in groups of 8 in cages on a 10-h photoperiod of incandescent light and maintained at an illuminance of 3 or 25 lux, or transferred from 3 to 25 lux or from 25 to 3 lux at 63 or 112 d of age. 2. There was no significant difference in sexual maturity, measured as eggs per 100 bird.d at 139 and 140 d, for ISA Brown maintained on 3 or 25 lux, but Shaver White pullets exposed to constant 3 lux matured significantly later than those maintained on 25 lux. 3. In Shaver Whites, sexual maturity was significantly delayed by an increase from 3 to 25 lux at 63 and 112 d, and advanced by a decrease from 25 to 3 lux at 112 d. Sexual maturity of ISA Browns was not significantly affected by a change in illuminance at 63 or 112 d, though responses were in the same direction as for Shaver Whites. 4. In both breeds, total feed consumed to 112 d was higher for birds on 3 lux than 25 lux, but lower between 112 d and 140 d when birds on 25 lux underwent rapid sexual development. In both breeds, body weight at 63 d was higher for birds exposed to 3 lux than 25 lux, but body weight gain thereafter was similar for the two light intensities. 5. In both breeds, plasma luteinising hormone (LH) concentration at 63 and 112 d was lower in birds maintained on 3 lux than 25 lux. At 63 and 112 d, transfers from 25 to 3 lux depressed, whereas transfers from 3 to 25 lux at 63 d, but not at 112 d, increased plasma LH. 6. Advances or delays in sexual maturity induced by changes in illuminance were not correlated with differences in feed intake, body weight gain, or with changes in plasma LH. 7. One possible explanation for the inverse relationship between the direction of change in illuminance at 63 and 112 d in pullets exposed to a 10-h photoperiod and the age at which they became sexually mature is that changes in light intensity and/or spectral composition affect the entrainment of the circadian rhythm of photoinducibility, to effect a phase shift in the photoinducible phase and/or the responsiveness of phototransduction pathways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extended research project, funded by the Thomas Pocklington Trust, and carried out by the Research Group for Inclusive Environments (RGIE) at The University of Reading, has examined the lighting found in the homes of people who are visually impaired (VIP). This paper will summarise the results of this substantive study. All the surveyed homes have been occupied by people with sight loss, some of the dwellings were shared with sighted partners. There are several safety issues concerning domestic lighting where inadequate provision may contribute to the incidence of personal injuries occurring in the home. Qualitative and quantitative data from questionnaires, photometric surveys and faceto- face interviews have been obtained from 57 homes. The nature and extent of the visual impairment of each study participant has been identified. This paper will identify important findings from the study, including: a range of areas and tasks within the home that visually impaired people find inadequately lit; the variability of illuminance provided for task lighting and general lighting; and how effective visually impaired people find a selection different lighting systems to those that they commonly use. The research team are able to offer preliminary design guidance for lighting the homes of people who are visually impaired. These will be summarised in the paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mirror lightpipes are useful for providing healthy and energy-efficient daylight into buildings where windows and skylights are unsuitable, insufficient or generate too much heat gain. The lightpipes have been installed in dozens of buildings in the UK. Field monitoring has been carried out to assess their performance in four different buildings: the headquaters of a major insurance company, a health clinic, a residential building and a college dining hall In those cases where lighipipes with moderate aspect ratios were installed, good illuminance of up to 450 lux has been obtained with internal/external illuminance ratios around 1%. When long and narrow lightpipes with many bends are used, however, the ratio reduced to around 0.1%. These results showed that lightpipes can be effective daylighting devices provided that excessive aspect ratios and numbers of bends are avoided. Lightpipes with larger diameters should be used whenever possible. The lightpipes often improved signiScantly the visual quality af the interior environment, and high user satisfaction was found even in buildings where a relatively low level of daylight was admitted through the lightpipes