921 resultados para Hearing Aids
Resumo:
This paper examines the return rate for digital hearing aids and reason for the returns.
Resumo:
This paper evaluates the directional effects of two hearing devices – an antique London Dome horn style device and a constructed Cupped Hand. The comparisons were made using the Quick SIN (Speech in Noise) adaptive test which measures signal-to-noise ratio loss.
Resumo:
This paper examines the return rate for digital hearing aids and reason for the returns.
Resumo:
The purpose of this study was to examine objective and subjective distortion present when frequency modulation (FM) systems were coupled with four digital signal processing (DSP) hearing aids. Electroacoustic analysis and subjective listening tests by experienced audiologists revealed that distortion levels varied across hearing aids and channels.
Resumo:
This paper discusses the results of a study to determine the differences between hearing aids and radiant beamforming technology.
Resumo:
This dissertation examines the relationship between frequency response and word-discrimination performance of hearing-impaired persons. Three questions are addressed: does the restoration of the normal field-to-eardrum transfer function improve word discrimination; is the restoration of the normal shape of the audibility curve (uniform hearing level at all frequencies) beneficial to hearing-impaired listeners; and can speech discrimination be improved by an extension of the present narrow-band response in hearing aids.
Resumo:
The notion that the default telecoil (t-coil) frequency response should match the programmed microphone frequency response to provide optimal telephone understanding for hearing aid patients has received little attention. This study addresses differences in the average frequency response of the two transducers in behind-the-ear (BTE) hearing aids.
Resumo:
The occurrence of directional microphone drift following hearing aid use has been infrequently examined. This study uses the front-to-side ratio to evaluate changes in directional microphone output from new behind-the-ear hearing aids and following approximately three months of hearing aid use. Results indicate no overall significant differences in the front-to-side ratio between initial and follow-up measurements.
Resumo:
OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.
Resumo:
CONCLUSIONS: Speech understanding is better with the Baha Divino than with the Baha Compact in competing noise from the rear. No difference was found for speech understanding in quiet. Subjectively, overall sound quality and speech understanding were rated better for the Baha Divino. OBJECTIVES: To compare speech understanding in quiet and in noise and subjective ratings for two different bone-anchored hearing aids: the recently developed Baha Divino and the Baha Compact. PATIENTS AND METHODS: Seven adults with bilateral conductive or mixed hearing losses who were users of a bone-anchored hearing aid were tested with the Baha Compact in quiet and in noise. Tests were repeated after 3 months of use with the Baha Divino. RESULTS: There was no significant difference between the two types of Baha for speech understanding in quiet when tested with German numbers and monosyllabic words at presentation levels between 50 and 80 dB. For speech understanding in noise, an advantage of 2.3 dB for the Baha Divino vs the Baha Compact was found, if noise was emitted from a loudspeaker to the rear of the listener and the directional microphone noise reduction system was activated. Subjectively, the Baha Divino was rated statistically significantly better in terms of overall sound quality.
Resumo:
OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.
Resumo:
OBJECTIVES To establish whether complex signal processing is beneficial for users of bone anchored hearing aids. METHODS Review and analysis of two studies from our own group, each comparing a speech processor with basic digital signal processing (either Baha Divino or Baha Intenso) and a processor with complex digital signal processing (either Baha BP100 or Baha BP110 power). The main differences between basic and complex signal processing are the number of audiologist accessible frequency channels and the availability and complexity of the directional multi-microphone noise reduction and loudness compression systems. RESULTS Both studies show a small, statistically non-significant improvement of speech understanding in quiet with the complex digital signal processing. The average improvement for speech in noise is +0.9 dB, if speech and noise are emitted both from the front of the listener. If noise is emitted from the rear and speech from the front of the listener, the advantage of the devices with complex digital signal processing as opposed to those with basic signal processing increases, on average, to +3.2 dB (range +2.3 … +5.1 dB, p ≤ 0.0032). DISCUSSION Complex digital signal processing does indeed improve speech understanding, especially in noise coming from the rear. This finding has been supported by another study, which has been published recently by a different research group. CONCLUSIONS When compared to basic digital signal processing, complex digital signal processing can increase speech understanding of users of bone anchored hearing aids. The benefit is most significant for speech understanding in noise.
Theory-of-mind development in oral deaf children with cochlear implants or conventional hearing aids
Resumo:
Background: In the context of the established finding that theory-of-mind (ToM) growth is seriously delayed in late-signing deaf children, and some evidence of equivalent delays in those learning speech with conventional hearing aids, this study's novel contribution was to explore ToM development in deaf children with cochlear implants. Implants can substantially boost auditory acuity and rates of language growth. Despite the implant, there are often problems socialising with hearing peers and some language difficulties, lending special theoretical interest to the present comparative design. Methods: A total of 52 children aged 4 to 12 years took a battery of false belief tests of ToM. There were 26 oral deaf children, half with implants and half with hearing aids, evenly divided between oral-only versus sign-plus-oral schools. Comparison groups of age-matched high-functioning children with autism and younger hearing children were also included. Results: No significant ToM differences emerged between deaf children with implants and those with hearing aids, nor between those in oral-only versus sign-plus-oral schools. Nor did the deaf children perform any better on the ToM tasks than their age peers with autism. Hearing preschoolers scored significantly higher than all other groups. For the deaf and the autistic children, as well as the preschoolers, rate of language development and verbal maturity significantly predicted variability in ToM, over and above chronological age. Conclusions: The finding that deaf children with cochlear implants are as delayed in ToM development as children with autism and their deaf peers with hearing aids or late sign language highlights the likely significance of peer interaction and early fluent communication with peers and family, whether in sign or in speech, in order to optimally facilitate the growth of social cognition and language.