893 resultados para Head neck
Resumo:
Knowledge of the accuracy of dose calculations in intensity-modulated radiotherapy of the head and neck is essential for clinical confidence in these highly conformal treatments. High dose gradients are frequently placed very close to critical structures, such as the spinal cord, and good coverage of complex shaped nodal target volumes is important for long term-local control. A phantom study is presented comparing the performance of standard clinical pencil-beam and collapsed-cone dose algorithms to Monte Carlo calculation and three-dimensional gel dosimetry measurement. All calculations and measurements are normalized to the median dose in the primary planning target volume, making this a purely relative study. The phantom simulates tissue, air and bone for a typical neck section and is treated using an inverse-planned 5-field IMRT treatment, similar in character to clinically used class solutions. Results indicate that the pencil-beam algorithm fails to correctly model the relative dose distribution surrounding the air cavity, leading to an overestimate of the target coverage. The collapsed-cone and Monte Carlo results are very similar, indicating that the clinical collapsed-cone algorithm is perfectly sufficient for routine clinical use. The gel measurement shows generally good agreement with the collapsed-cone and Monte Carlo calculated dose, particularly in the spinal cord dose and nodal target coverage, thus giving greater confidence in the use of this class solution.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
The main objective is to generate kinematic models for the head and neck movements. The motivation comes from our study of individuals with quadriplegia and the need to design rehabilitation aiding devices such as robots and teletheses that can be controlled by head-neck movements. It is then necessary to develop mathematical models for the head and neck movements. Two identification methods have been applied to study the kinematics of head-neck movements of able-body as well as neck-injured subjects. In particular, sagittal plane movements are well modeled by a planar two-revolute-joint linkage. In fact, the motion in joint space seems to indicate that sagittal plane movements may be classified as a single DOF motion. Finally, a spatial three-revolute-joint system has been employed to model 3D head-neck movements.
Resumo:
A detailed genome mapping analysis of 213,636 expressed sequence tags (EST) derived from nontumor and tumor tissues of the oral cavity, larynx, pharynx, and thyroid was done. Transcripts matching known human genes were identified; potential new splice variants were flagged and subjected to manual curation, pointing to 788 putatively new alternative splicing isoforms, the majority (75%) being insertion events. A subset of 34 new splicing isoforms (5% of 788 events) was selected and 23 (68%) were confirmed by reverse transcription-PCR and DNA sequencing. Putative new genes were revealed, including six transcripts mapped to well-studied chromosomes such as 22, as well as transcripts that mapped to 253 intergenic regions. In addition, 2,251 noncoding intronic RNAs, eventually involved in transcriptional regulation, were found. A set of 250 candidate markers for loss of heterozygosis or gene amplification was selected by identifying transcripts that mapped to genomic regions previously known to be frequently amplified or deleted in head, neck, and thyroid tumors. Three of these markers were evaluated by quantitative reverse transcription-PCR in an independent set of individual samples. Along with detailed clinical data about tumor origin, the information reported here is now publicly available on a dedicated Web site as a resource for further biological investigation. This first in silico reconstruction of the head, neck, and thyroid transcriptomes points to a wealth of new candidate markers that can be used for future studies on the molecular basis of these tumors. Similar analysis is warranted for a number of other tumors for which large EST data sets are available.
Resumo:
Review paper and Proceedings of the Inaugural Meeting of the Head and Neck Optical Diagnostics Society (HNODS) on March 14th 2009 at University College London.
Resumo:
The proximal femur is a high-diversity region of the human skeleton, especially at the anterior junction between head and neck, where various bony morphologies have been recognized since mid nineteenth century. Classical literature on this topic is chaotic and contradictory, making almost impossible the comparison of data from different researches. Starting from an extensive bibliographic review, the first standardized method to score these traits has been created. This method allows representing both the anatomical diversity of the region already described in literature and a part of variability not considered before, giving few and univocal definitions and allowing to collect comparable data. The method has been applied to three identified and five archaeological European skeletal collections, with the aim of investigating the distribution of these features by sex, age and side, in different places and time periods. It has also been applied to 3D digital reconstructions of femurs from CT scan files of coxo-femoral joints from fresh cadavers. In addition to the osseous traits described in the standardized method, the presence and frequency of some features known as herniation pits have been scored both on bones and on CT scans. The various osseous traits of the proximal femur are present at similar frequencies in skeletal samples from different countries and different historical periods, even if with clear local differentiation. Some of the features examined show significant trends related to their distribution by gender and age. Some hypotheses are proposed about the etiology of these morphologies and their possible implication with the acquisition of bipedalism in Humans. It is therefore highlighted the possible relation of some of these traits with the development of disorders of the hip joint. Moreover, it is not recommended the use of any of these features as a specific activity-related marker.
Resumo:
Surgical navigation might increase the safety of osteochondroplasty procedures in patients with femoroacetabular impingement. Feasibility and accuracy of navigation of a surgical reaming device were assessed. Three-dimensional models of 18 identical sawbone femora and 5 cadaver hips were created. Custom software was used to plan and perform repeated computer-assisted osteochondroplasty procedures using a navigated burr. Postoperative 3-dimensional models were created and compared with the preoperative models. A Bland-Altmann analysis assessing α angle and offset ratio accuracy showed even distribution along the zero line with narrow confidence intervals. No differences in α angle and offset ratio accuracy (P = 0.486 and P = 0.2) were detected between both observers. Planning and conduction of navigated osteochondroplasty using a surgical reaming device is feasible and accurate.
Resumo:
Early radiographic detection of femoroacetabular impingement might prevent initiation and progression of osteoarthritis. The structural abnormality in femoral-induced femoroacetabular impingement (cam type) is frequently asphericity at the anterosuperior head/neck contour. To determine which of six radiographic projections (anteroposterior, Dunn, Dunn/45 degrees flexion, cross-table/15 degrees internal rotation, cross-table/neutral rotation, and cross-table/15 degrees external rotation) best identifies femoral head/neck asphericity, we studied 21 desiccated femurs; 11 with an aspherical femoral head/neck contour and 10 with a spherical femoral head/neck contour. To radiographically quantify femoral head asphericity, we measured the angle where the femoral head/neck leaves sphericity (angle alpha). The aspherical femoral head/neck contours had a greater maximum angle alpha (70 degrees ) compared with the spherical head/neck contours (50 degrees ). The angle alpha varied depending on the radiographic projection: it was greatest in the Dunn view with 45 degrees hip flexion (71 degrees +/- 10 degrees ) and least in the cross-table view in 15 degrees external rotation (51 degrees +/- 7 degrees ). Diagnosis of a pathologic femoral head/neck contour depends on the radiologic projection. The Dunn view in 45 degrees or 90 degrees flexion or a cross-table projection in internal rotation best show femoral head/neck asphericity, whereas anteroposterior or externally rotated cross-table views are likely to miss asphericity. Level of Evidence: Prognostic study, level II-1 (retrospective study).
Resumo:
Asphericity of the femoral head-neck junction is one cause for femoroacetabular impingement of the hip. However, the asphericity often is underestimated on conventional radiographs. This study compares the presence of asphericity on conventional radiographs with its appearance on radial slices of magnetic resonance arthrography (MRA). We retrospectively reviewed 58 selected hips in 148 patients who underwent a surgical dislocation of the hip. To assess the circumference of the proximal femur, alpha angle and height of asphericity were measured in 14 positions using radial slices of MRA. The hips were assigned to one of four groups depending on the appearance of the head-neck junction on anteroposterior pelvic and lateral crosstable radiographs. Group I (n = 19) was circular on both planes, Group II (n = 19) was aspheric on the crosstable view, Group III (n = 4) was aspheric on the anteroposterior view, and Group IV (n = 13) was aspheric on both views. In all four groups, the highest alpha angle was found in the anterosuperior area of the head-neck junction. Even when conventional radiographs appeared normal, an increased alpha angle was present anterosuperiorly. Without the use of radial slices in MRA, the asphericity would be underestimated in these patients.
Resumo:
National Highway Traffic Safety Administration, Vehicle Research and Test Center, East Liberty, Ohio
Resumo:
National Highway Traffic Safety Administration, Vehicle Research and Test center, East Liberty, Ohio