990 resultados para HIV antibody tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction; The awareness of HIV positiveness is important for health of the individual and of the comunity. The identicatio of HIV antibodies is possible both using conventional lab tests and quick result tests. In the bibliography it was made clear that there are no instruments in Portuguese to assert the reactions to the HIV quick tests and it was therefore considered it would be useful to adapt and validate a scale in Portuguese, since the language is the official language of 7 different countries and spoken by more than 250 milion people, Objectives: the purpose is to validate a version in European Portuguese of the HIV Antibody Testing Attitude Scale. Methods: the study refers to methodological research for the adaptation and validation of an instrument of attitude measurement. A translation and back-translation was prepared and a trial test was then carried out. A total of 317 students, lectures and co-workers of a Portuguese University was interviewes. Ethical principles were taken into consideration. the pool was obtained in the seven components of the University campus. Results: 3 trials of factorial testing of the main components of 5, 4 and 3 factors. It ended up a solution of 3 factors that explains 50.82% of the variability. In the analysis of the inter-items correlation values of between 0.018 and 0.749 were observed. The internal consistency reveals an alpha Cronbach coefficient of 0.860 as a whole, and in between 0,865 and 0.659 in the 3 factors. Conclusions: this version of the instrument shows that the psychometric properties allow its use in the Portuguese speaking countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. Methods. We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. Results. Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. Conclusion. These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing. (J Rheumatol 2001;28:1584-90)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"X48896"--Colophon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To culturally adapt and validate a version in European Portuguese language of the HIV Antibody Testing Attitude Scale. Methods. Study conducting a methodological investigation for the adaptation and validation of an attitude measurement instrument. The instrument translation and back-translation were performed. Then, a pre-test was conducted. The study used a sample of 317 subjects from the academic community - students, professors and other professionals - who were contacted in the campus. Ethical principles were observed. Results. Three analyses were conducted using the method of principal component analysis (PCA) with five, four and three factors. A three-factor solution was achieved, which presents 50.82% variance. In the analysis of inter-item correlation, values between -0.018 and 0.749 were observed. Internal consistency shows Cronbach’s alpha coefficients of 0.860 overall and between 0.865 and 0.659 in the three factors. Conclusion. The instrument version shows psychometric properties that allow its use in Portuguese-speaking countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of the number of recent HIV infections is important for epidemiologic surveillance. Over the past decade approaches have been developed to estimate this number by testing HIV-seropositive specimens with assays that discriminate the lower concentration and avidity of HIV antibodies in early infection. We have investigated whether this "recency" information can also be gained from an HIV confirmatory assay. METHODS AND FINDINGS: The ability of a line immunoassay (INNO-LIA HIV I/II Score, Innogenetics) to distinguish recent from older HIV-1 infection was evaluated in comparison with the Calypte HIV-1 BED Incidence enzyme immunoassay (BED-EIA). Both tests were conducted prospectively in all HIV infections newly diagnosed in Switzerland from July 2005 to June 2006. Clinical and laboratory information indicative of recent or older infection was obtained from physicians at the time of HIV diagnosis and used as the reference standard. BED-EIA and various recency algorithms utilizing the antibody reaction to INNO-LIA's five HIV-1 antigen bands were evaluated by logistic regression analysis. A total of 765 HIV-1 infections, 748 (97.8%) with complete test results, were newly diagnosed during the study. A negative or indeterminate HIV antibody assay at diagnosis, symptoms of primary HIV infection, or a negative HIV test during the past 12 mo classified 195 infections (26.1%) as recent (< or = 12 mo). Symptoms of CDC stages B or C classified 161 infections as older (21.5%), and 392 patients with no symptoms remained unclassified. BED-EIA ruled 65% of the 195 recent infections as recent and 80% of the 161 older infections as older. Two INNO-LIA algorithms showed 50% and 40% sensitivity combined with 95% and 99% specificity, respectively. Estimation of recent infection in the entire study population, based on actual results of the three tests and adjusted for a test's sensitivity and specificity, yielded 37% for BED-EIA compared to 35% and 33% for the two INNO-LIA algorithms. Window-based estimation with BED-EIA yielded 41% (95% confidence interval 36%-46%). CONCLUSIONS: Recency information can be extracted from INNO-LIA-based confirmatory testing at no additional costs. This method should improve epidemiologic surveillance in countries that routinely use INNO-LIA for HIV confirmation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of the number of recent HIV infections is important for epidemiologic surveillance. Over the past decade approaches have been developed to estimate this number by testing HIV-seropositive specimens with assays that discriminate the lower concentration and avidity of HIV antibodies in early infection. We have investigated whether this "recency" information can also be gained from an HIV confirmatory assay. METHODS AND FINDINGS: The ability of a line immunoassay (INNO-LIA HIV I/II Score, Innogenetics) to distinguish recent from older HIV-1 infection was evaluated in comparison with the Calypte HIV-1 BED Incidence enzyme immunoassay (BED-EIA). Both tests were conducted prospectively in all HIV infections newly diagnosed in Switzerland from July 2005 to June 2006. Clinical and laboratory information indicative of recent or older infection was obtained from physicians at the time of HIV diagnosis and used as the reference standard. BED-EIA and various recency algorithms utilizing the antibody reaction to INNO-LIA's five HIV-1 antigen bands were evaluated by logistic regression analysis. A total of 765 HIV-1 infections, 748 (97.8%) with complete test results, were newly diagnosed during the study. A negative or indeterminate HIV antibody assay at diagnosis, symptoms of primary HIV infection, or a negative HIV test during the past 12 mo classified 195 infections (26.1%) as recent (< or = 12 mo). Symptoms of CDC stages B or C classified 161 infections as older (21.5%), and 392 patients with no symptoms remained unclassified. BED-EIA ruled 65% of the 195 recent infections as recent and 80% of the 161 older infections as older. Two INNO-LIA algorithms showed 50% and 40% sensitivity combined with 95% and 99% specificity, respectively. Estimation of recent infection in the entire study population, based on actual results of the three tests and adjusted for a test's sensitivity and specificity, yielded 37% for BED-EIA compared to 35% and 33% for the two INNO-LIA algorithms. Window-based estimation with BED-EIA yielded 41% (95% confidence interval 36%-46%). CONCLUSIONS: Recency information can be extracted from INNO-LIA-based confirmatory testing at no additional costs. This method should improve epidemiologic surveillance in countries that routinely use INNO-LIA for HIV confirmation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Although hepatitis C virus (HCV) screening is recommended for all HIV-infected patients initiating antiretroviral therapy, data on epidemiologic characteristics of HCV infection in resource-limited settings are scarce. METHODS We searched PubMed and EMBASE for studies assessing the prevalence of HCV infection among HIV-infected individuals in Africa and extracted data on laboratory methods used. Prevalence estimates from individual studies were combined for each country using random-effects meta-analysis. The importance of study design, population and setting as well as type of test (anti-HCV antibody tests and polymerase chain reactions) was examined with meta-regression. RESULTS Three randomized controlled trials, 28 cohort studies and 121 cross-sectional analyses with 108,180 HIV-infected individuals from 35 countries were included. The majority of data came from outpatient populations (55%), followed by blood donors (15%) and pregnant women (14%). Based on estimates from 159 study populations, anti-HCV positivity prevalence ranged between 3.3% (95% confidence interval (CI) 1.8-4.7) in Southern Africa and 42.3% (95% CI 4.1-80.5) in North Africa. Study design, type of setting and age distribution did not influence this prevalence significantly. The prevalence of replicating HCV infection, estimated from data of 29 cohorts, was 2.0% (95% CI 1.5-2.6). Ten studies from nine countries reported the HCV genotype of 74 samples, 53% were genotype 1, 24% genotype 2, 14% genotype 4 and 9% genotypes 3, 5 or 6. CONCLUSIONS The prevalence of anti-HCV antibodies is high in HIV-infected patients in Africa, but replicating HCV infection is rare and varies widely across countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nucleic acid sequence-based amplification (NASBA) has proved to be an ultrasensitive method for HIV-1 diagnosis in plasma even in the primary HIV infection stage. This technique was combined with fluorescence correlation spectroscopy (FCS) which enables online detection of the HIV-1 RNA molecules amplified by NASBA. A fluorescently labeled DNA probe at nanomolar concentration was introduced into the NASBA reaction mixture and hybridizing to a distinct sequence of the amplified RNA molecule. The specific hybridization and extension of this probe during amplification reaction, resulting in an increase of its diffusion time, was monitored online by FCS. As a consequence, after having reached a critical concentration of 0.1–1 nM (threshold for unaided FCS detection), the number of amplified RNA molecules in the further course of reaction could be determined. Evaluation of the hybridization/extension kinetics allowed an estimation of the initial HIV-1 RNA concentration that was present at the beginning of amplification. The value of initial HIV-1 RNA number enables discrimination between positive and false-positive samples (caused for instance by carryover contamination)—this possibility of discrimination is an essential necessity for all diagnostic methods using amplification systems (PCR as well as NASBA). Quantitation of HIV-1 RNA in plasma by combination of NASBA with FCS may also be useful in assessing the efficacy of anti-HIV agents, especially in the early infection stage when standard ELISA antibody tests often display negative results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We assessed the association between the causative agents of vaginal discharge and pelvic inflammatory disease (PID) among women attending a rural sexually transmitted disease clinic in South Africa; the role played by coinfection with human immunodeficiency virus type 1 (HIV-1) was studied. Vaginal and cervical specimens were obtained to detect Neisseria gonorrhoeae, Chlamydia trachomatis, Trichomonas vaginalis, and bacterial vaginosis. HIV-1 infection was established by use of serum antibody tests. A total of 696 women with vaginal discharge were recruited, 119 of whom had clinical PID. Patients with trichomoniasis had a significantly higher risk of PID than did women without trichomoniasis (P = .03). PID was not associated with any of the other pathogens. When the patients were stratified according to HIV-1 status, the risk of PID in HIV-1-infected patients with T. vaginalis increased significantly (P = .002); no association was found in patients without HIV-1. T. vaginalis infection of the lower genital tract is associated with a clinical diagnosis of PID in HIV-1-infected women.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To investigate differences in HIV infection- related risk practices by Female Sex Workers according to workplace and the effects of homophily on estimating HIV prevalence. METHODS Data from 2,523 women, recruited using Respondent-Driven Sampling, were used for the study carried out in 10 Brazilian cities in 2008-2009. The study included female sex workers aged 18 and over. The questionnaire was completed by the subjects and included questions on characteristics of professional activity, sexual practices, use of drugs, HIV testing, and access to health services. HIV quick tests were conducted. The participants were classified in two groups according to place of work: on the street or indoor venues, like nightclubs and saunas. To compare variable distributions by place of work, we used Chi-square homogeneity tests, taking into consideration unequal selection probabilities as well as the structure of dependence between observations. We tested the effect of homophily by workplace on estimated HIV prevalence. RESULTS The highest HIV risk practices were associated with: working on the streets, lower socioeconomic status, low regular smear test coverage, higher levels of crack use and higher levels of syphilis serological scars as well as higher prevalence of HIV infection. The effect of homophily was higher among sex workers in indoor venues. However, it did not affect the estimated prevalence of HIV, even after using a post-stratification by workplace procedure. CONCLUSIONS The findings suggest that strategies should focus on extending access to, and utilization of, health services. Prevention policies should be specifically aimed at street workers. Regarding the application of Respondent-Driven Sampling, the sample should be sufficient to estimate transition probabilities, as the network develops more quickly among sex workers in indoor venues.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The rate of mother-to-child transmission (MTCT) of HIV as well as the implications of the circulating multiple subtypes to MTCT in Nigeria are not known. This study was therefore undertaken to determine the differential rates of MTCT of HIV-1 subtypes detected among infected pregnant women before ARV intervention therapy became available in Nigeria. Twenty of the HIV-positive women who signed the informed consent form during pregnancy brought their babies for follow-up testing at age 18-24 months. Plasma samples from both mother and baby were tested for HIV antibody at the Department of Virology, UCH, Ibadan, Nigeria. All positive samples (plasma and peripheral blood mononuclear cells - PBMCs) were shipped to the Institute of Tropical Medicine, Antwerp, Belgium, where the subtype of the infecting virus was determined using the HMA technique. Overall, a mother-to-child HIV transmission rate of 45% was found in this cohort. Specifically, 36.4%, 66.7% and 100% of the women infected with HIV-1 CRF02 (IbNg), G and B, respectively, transmitted the virus to their babies. As far as it can be ascertained, this is the first report on the rate of MTCT of HIV in Nigeria. The findings reported in this paper will form a useful reference for assessment of currently available therapeutic intervention of MTCT in the country.