55 resultados para Firefighters
Resumo:
Exposure to aqueous film forming foam (AFFF) was evaluated in 149 firefighters working at AFFF training facilities in Australia by analysis of PFOS and related compounds in serum. A questionnaire was designed to capture information about basic demographic factors, lifestyle factors and potential occupational exposure (such as work history and self-reported skin contact with foam). The results showed that a number of factors were associated with PFAA serum concentrations. Blood donation was found to be linked to low PFAA levels, and the concentrations of PFOS and PFHxS were found to be positively associated with years of jobs with AFFF contact. The highest levels of PFOS and PFHxS were one order of magnitude higher compared to the general population in Australia and Canada. Study participants who had worked ten years or less had levels of PFOS that were similar to or only slightly above those of the general population. This coincides with the phase out of 3M AFFF from all training facilities in 2003, and suggests that the exposures to PFOS and PFHxS in AFFF have declined in recent years. Self-reporting of skin contact and frequency of contact were used as an index of exposure. Using this index, there was no relationship between PFOS levels and skin exposure. This index of exposure is limited as it relies on self-report and it only considers skin exposure to AFFF, and does not capture other routes of potential exposure. Possible associations between serum PFAA concentrations and five biochemical outcomes were assessed. The outcomes were serum cholesterol, triglycerides, high-density lipoproteins, low density lipoproteins, and uric acid. No statistical associations between any of these endpoints and serum PFAA concentrations were observed.
Resumo:
Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.
Resumo:
A real-time cooperative localization system, utilizing dual foot-mounted low-cost inertial sensors and RF-based inter-agent ranging, has been developed. Scenario-based tests have been performed, using fully-equipped firefighters mimicking a search operation in a partly smoke-filled environment, to evaluate the performance of the TOR (Tactical lOcatoR) system. The performed tests included realistic firefighter movements and inter-agent distances, factors that are crucial in order to provide realistic evaluations of the expected performance in real-world operations. The tests indicate that the TOR system may be able to provide a position accuracy of approximately two to three meters during realistic firefighter operations, with only two smoke diving firefighters and one supervising firefighter within range.
Resumo:
Variation in hiring procedures occurs within fire service human resource departments. In this study, City 1 and City 2 applicants were required to pass their biophysical assessments prior to being hired as firefighters at the beginning and end of the screening process, respectively. City 1 applicants demonstrated significantly lower resting heart rate (RHR), resting diastolic blood pressure (RDBP), body fat% (BF) and higher z-scores for BF, trunk flexibility (TF) and overall clinical assessment (p<0.05). Regression analysis found that age and conducting the biophysical assessment at the end of the screening process explained poorer biophysical assessment results in BF% (R2=21%), BF z-score (R2=22%), TF z-score (R2=10%) and overall clinical assessment z-score (R2=7%). Each of RHR (OR=1.06, CI=1.01-1.10), RDBP (OR=1.05, CI=1.00-1.11) and BF% (OR=1.20, CI=1.07-1.37) increased the odds of being a City 2 firefighter (p<0.05). Biophysical screening at the end of the hiring process may result in the hiring of a less healthy firefighter.
Resumo:
This paper examines the risks of occupational noise induced hearing loss in firefighters. OSHA and National Institute for Occupational Safety and Health (NIOSH) guidelines are described and noise data collected from the Blue Island (Illinois) Fire Department is analyzed.
Resumo:
Immediate replantation into the socket is the ideal procedure in cases of accidental avulsion of permanent teeth. In Brazil, firefighters with special paramedic training are in charge of providing first-aid care to victims of road accidents and might have to deal with tooth avulsions. This study assessed the knowledge of firefighters regarding the emergency management of avulsed teeth. Information was collected from a questionnaire submitted to 110 volunteer firefighters in seven cities in the São Paulo State (Brazil). The results revealed that 70.9% of the respondents did not know what tooth avulsion was; 53.6% did not know what tooth replantation was or defined it incorrectly; 60% would not act properly in tooth avulsion cases; 20.9% did not consider replantation of the avulsed tooth into the socket as a treatment option; the ideal time interval for tooth replantation was unknown to 40% of the interviewees; 90% of the participants answered that they would not be able to perform tooth replantation. Among those who considered themselves unable to perform tooth replantation, 47.3% chose saline as the best storage medium for an avulsed tooth, 21.8% chose milk, 3.6% chose the patient's mouth and 20% reported not knowing where to store the tooth; 81.8% of the firefighters reported not to have ever received any specific directions on tooth replantation and 100% of them considered this knowledge a requirement for first-aid care to accident victims. In conclusion, the knowledge of the surveyed firefighters regarding emergency management after tooth avulsion was unsatisfactory in several aspects that are important for the success of replantation procedures. Firefighters with special paramedic training should be educated on how to proceed in cases of dentoalveolar traumas and tooth avulsions in order to improve treatment prognosis and increase the survival rate of replanted teeth.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Firefighting is widely known to be one of the most physically demanding civilian occupations. A subset of this is Industrial Firefighting, which places similarly high physical demands on Industrial Firefighters. Although there are some studies on community firefighters, literature is scant on Industrial Firefighters and their physical fitness. ^ A cross-sectional study of Industrial Firefighters in Petrochemical companies in Texas was carried out in 1996–98 to assess their physical fitness and to develop a set of physical agility criteria useful in their selection and ongoing fitness for duty evaluations. ^ A physical agility criteria and a fitness scorecard was developed based on seven parameters (resting heart rate, diastolic blood pressure, aerobic capacity, muscle strength, muscle endurance, trunk flexibility and total body fat) of musculoskeletal and cardiorespiratory fitness. Each indicator received a minimum of 0 to a maximum of 20 points, based on individual performance. Therefore a minimum and maximum achievable score for the entire battery of tests was 0 and 140 respectively. Of the 111 study subjects, 5 (4.5%) were far above average, 31 (28%) above average, 46 (41.5 %) average, 29 (26%) below average and 0 (0%) far below average as deemed by the physical fitness scorecard. The mean score was 77 (±23) with a minimum and maximum score of 35 and 135 respectively. ^ Following univariate analysis an exploratory factor analysis to group variables and to assess the overall role of constituent variables in total fitness of a firefighter was developed. This was followed by a stepwise linear regression analysis using aerobic capacity as a dependent variable. ^ Finally, a graded implementation strategy was devised, such that all existing Industrial Firefighters would have an opportunity to improve or maintain their physical fitness at or above average level as deemed by the fitness scorecard. ^
Resumo:
Mode of access: Internet.
Resumo:
Cover title.
Resumo:
"Serial no. 96-113."
Resumo:
No more published?