973 resultados para Failure testing


Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: Currently available volar locking plates for the treatment of distal radius fractures incorporate at least two distal screw rows for fixation of the metaphyseal fragment and have a variable-angle locking mechanism which allows placement of the screws in various directions There is, however no evidence that these plates translate into better outcomes or have superior biomechanical properties to first generation plates, which had a single distal screw row and fixed-angle locking. The aim of our biomechanical study was to compare fixed-angle single-row plates with variable-angle multi-row plates to clarify the optimal number of locking screws. MATERIALS AND METHODS: Five different plate-screw combinations of three different manufacturers were tested, each group consisting of five synthetic fourth generation distal radius bones. An AO type C2 fracture was created and the fractures were plated according to each manufacturer's recommendations. The specimens then underwent cyclic and load-to-failure testing. An optical motion analysis system was used to detect displacement of fragments. RESULTS: No significant differences were detected after cyclic loading as well as after load-to-failure testing, neither in regard to axial deformation, implant rigidity or maximum displacement. The fixed-angle single-row plate showed the highest pre-test rigidity, least increase in post-testing rigidity and highest load-to-failure rigidity and least radial shortening. The radial shortening of plates with two distal screw rows was 3.1 and 4.3 times higher, respectively, than that of the fixed-angle single-row plate. CONCLUSION: The results of our study indicate that two distal screw rows do not add to construct rigidity and resistance against loss of reduction. Well conducted clinical studies based on the findings of biomechanical studies are necessary to determine the optimal number of screws necessary to achieve reproducibly good results in the treatment of distal radius fractures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives. This paper attempts to provide critical perspectives on common in vitro research methodologies, including shear bond testing, wear testing, and load-to-failure tests. Origins of interest in high-quality laboratory data is reviewed, in vitro data is categorized into property and simulation protocols, and two approaches are suggested for establishing clinical validity. It is hoped that these insights will encourage further progress toward development of in vitro tests that are validated against clinical performance and/or by producing clinically validated failure or damage mechanisms.Materials and methods. Published shear and tensile bond data (macro and micro) is examined in light of published finite element analyses (FEA). This data is subjected to a Weibull scaling analysis to ascertain whether scaling is consistent with failure from the bonded interface or not. Wear tests results are presented in light of the damage mechanism(s) operating. Quantitative wear data is re-examined as being dependent upon contact pressure. Load-to-failure test results are re-analyzed by calculating contact stresses at failure for 119 tests from 54 publications over more than 25 years.Results. FEA analyses and reported failure modes (adhesive, mixed, cohesive) are consistent with failure not involving interfacial "shear stresses" as calculated in published work. Weibull scaling clearly suggests failure involving external surfaces of specimens, not interfacial origins. Contact stresses (pressures) are clearly an important variable in wear testing and are not well-controlled in published work. Load-to-failure tests create damage not seen clinically due to excessively high contact stresses. Most contact stresses in the 119 tests examined were calculated to be between 1000 MPa and 5000 MPa, whereas clinical contact stresses at wear facets have been measured not to exceed 40 MPa.Conclusions. Our community can do a much better job of designing in vitro tests that more closely simulate clinical conditions, especially when contact is involved. Journals are encouraged to thoughtfully consider a ban on publishing papers using bond tests and load-to-failure methods that are seriously flawed and have no clinical relevance. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To compare the biomechanical properties of a ventral transarticular lag screw fixation technique, a new dorsal atlantoaxial instability (AAI) clamp, and a new ventral AAI hook plate under sagittal shear loading after transection of the ligaments of the atlantoaxial joint. STUDY DESIGN: Cadaveric biomechanical study. ANIMALS: Canine cadavers (n = 10). MATERIALS AND METHODS: The occipitoatlantoaxial region of Beagles euthanatized for reasons unrelated to the study was prepared leaving only ligamentous structures and the joint capsules between the first 2 cervical vertebrae (C1 and C2). The atlanto-occipital joints were stabilized with 2 transarticular diverging positive threaded K-wires. The occipital bone and the caudal end of C2 were embedded in polymethylmethacrylate and loaded in shear to a force of 50 Newtons. The range of motion (ROM) and neutral zone (NZ) of the atlantoaxial joint were determined after 3 loading cycles with atlantoaxial ligaments intact, after ligament transection, and after fixation with each implant. The testing order of implants was randomly assigned. The implants tested last were subjected to failure testing. RESULTS: All stabilization procedures decreased the ROM and NZ of the atlantoaxial joint compared to transected ligament specimens. Only stabilization with transarticular lag screws and ventral plates produced a significant reduction of ROM compare to intact specimens. CONCLUSION: Fixation with transarticular lag screws and a ventral hook plate was biomechanically similar and provided more rigidity compared to dorsal clamp fixation. Further load cycling to failure tests and clinical studies are required before making clinical recommendations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Future air traffic management concepts often involve the proposal of automated separation management algorithms that replaces human air traffic controllers. This paper proposes a new type of automated separation management algorithm (based on the satisficing approach) that utilizes inter-aircraft communication and a track file manager (or bank of Kalman filters) that is capable of resolving conflicts during periods of communication failure. The proposed separation management algorithm is tested in a range of flight scenarios involving during periods of communication failure, in both simulation and flight test (flight tests were conducted as part of the Smart Skies project). The intention of the conducted flight tests was to investigate the benefits of using inter-aircraft communication to provide an extra layer of safety protection in support air traffic management during periods of failure of the communication network. These benefits were confirmed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: Heart failure (HF) is the leading cause of hospitalization and significant burden to the health care system in Australia. To reduce hospitalizations, multidisciplinary approaches and enhance self-management programs have been strongly advocated for HF patients globally. HF patients who can effectively manage their symptoms and adhere to complex medicine regimes will experience fewer hospitalizations. Research indicates that information technologies (IT) have a significant role in providing support to promote patients' self-management skills. The iPad utilizes user-friendly interfaces and to date an application for HF patient education has not been developed. This project aimed to develop the HF iPad teaching application in the way that would be engaging, interactive and simple to follow and usable for patients' carers and health care workers within both the hospital and community setting. Methods: The design for the development and evaluation of the application consisted of two action research cycles. Each cycle included 3 phases of testing and feedback from three groups comprising IT team, HF experts and patients. All patient education materials of the application were derived from national and international evidence based practice guidelines and patient self-care recommendations. Results: The iPad application has animated anatomy and physiology that simply and clearly teaches the concepts of the normal heart and the heart in failure. Patient Avatars throughout the application can be changed to reflect the sex and culture of the patient. There is voice-over presenting a script developed by the heart failure expert panel. Additional engagement processes included points of interaction throughout the application with touch screen responses and the ability of the patient to enter their weight and this data is secured and transferred to the clinic nurse and/or research data set. The application has been used independently, for instance, at home or using headphones in a clinic waiting room or most commonly to aid a nurse-led HF consultation. Conclusion: This project utilized iPad as an educational tool to standardize HF education from nurses who are not always heart failure specialists. Furthermore, study is currently ongoing to evaluate of the effectiveness of this tool on patient outcomes and to develop several specifically designed cultural adaptations [Hispanic (USA), Aboriginal (Australia), and Maori (New Zealand)].

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background/Aim There is a 70% higher age-adjusted incidence of heart failure (HF) amongst Aboriginal and Torres Strait Islander people, three times more hospitalisations and twice as many deaths than non-Aboriginal people. There is a need to develop holistic yet individualised approaches in accord with the values of Aboriginal community healthcare to support patient education and self-care. The aim of this study was to re-design an existing HF educational resource (Fluid Watchers-Pacific Rim©) to be culturally safe for Aboriginal and Torres Strait Islander peoples, working in collaboration with the local community, and to conduct feasibility testing. Methods This study was conducted in two phases and utilised a mixed methods approach (qualitative and quantitative). Phase 1 of this study used action research methods to develop a culturally safe electronic resource to be provided to Aboriginal HF patients via a tablet computer. A HF expert panel adapted the existing resource to ensure it was evidence-based and contained appropriate language and images that reflects Aboriginal culture. A stakeholder group (which included Aboriginal workers and HF patients, as well as researchers and clinicians) then reviewed the resources and changes were made accordingly. In Phase 2, the new resource was tested on a sample of Aboriginal HF patients to assess feasibility and acceptability. Patient knowledge, satisfaction and self-care behaviours were measured using a before and after design with validated questionnaires. As this was a pilot test to determine feasibility, no statistical comparisons were made. Results - Phase 1: Throughout the process of resource development, two main themes emerged from the stakeholder consultation. These were the importance of identity, meaning that it was important to ensure that the resource accurately reflected the local community, with the appropriate clothing, skin tone and voice. The resource was adapted to reflect this and of the local community voiced the recordings for the resource. The other theme was comprehension; images were important and all text was converted to the first person and used plain language. - Phase 2: Five Aboriginal participants, mean age 61.6 ± 10.0 years, with NYHA Class III and IV heart failure were enrolled. Participants reported a high level of satisfaction with the resource (83.0%). HF knowledge (percentage of correct responses) increased from 48.0 ± 6.7% to 58.0 ± 9.7%, a 20.8% increase and results of the self-care index indicated that the biggest change was in patient confidence for self-care with a 95% increase in confidence score (46.7 ± 16.0 to 91.1 ± 11.5). Changes in management and maintenance scores varied between9275 patients. Conclusion By working in collaboration with HF experts, Aboriginal researchers and patients, a culturally safe HF resource has been developed for Aboriginal and Torres Strait Islander patients. Engaging Aboriginal researchers, capacity-building, and being responsive to local systems and structures enabled this pilot study to be successfully completed with the Aboriginal community and positive participant feedback demonstrated that the methodology used in this study was appropriate and acceptable; participants were able to engage with willingness and confidence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The room temperature (RT) tensile behaviour of a free-standing high activity Pt-aluminide bond coat has been evaluated by microtensile testing technique. The coating had a typical three-layer microstructure. The stress-strain plot for the free-standing coating was linear, indicating the coating to be brittle at RT. Different fracture features were observed across the coating layers, namely quasi-cleavage in the outer layer and inner interdiffusion zone, and cleavage in the intermediate layer. By employing interrupted tensile test and observing the cross-sectional microstructure of the tested specimens, it was determined that failure of the microtensile samples occurred by the initiation of a single crack in the intermediate layer of the coating and its subsequent inside-out propagation. Such a mechanism of failure has been explained in terms of the fracture features observed across the sample thickness. This mechanism of failure is consistent with fracture toughness values of the individual coating layers. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Consider a J-component series system which is put on Accelerated Life Test (ALT) involving K stress variables. First, a general formulation of ALT is provided for log-location-scale family of distributions. A general stress translation function of location parameter of the component log-lifetime distribution is proposed which can accommodate standard ones like Arrhenius, power-rule, log-linear model, etc., as special cases. Later, the component lives are assumed to be independent Weibull random variables with a common shape parameter. A full Bayesian methodology is then developed by letting only the scale parameters of the Weibull component lives depend on the stress variables through the general stress translation function. Priors on all the parameters, namely the stress coefficients and the Weibull shape parameter, are assumed to be log-concave and independent of each other. This assumption is to facilitate Gibbs sampling from the joint posterior. The samples thus generated from the joint posterior is then used to obtain the Bayesian point and interval estimates of the system reliability at usage condition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Consider a J-component series system which is put on Accelerated Life Test (ALT) involving K stress variables. First, a general formulation of ALT is provided for log-location-scale family of distributions. A general stress translation function of location parameter of the component log-lifetime distribution is proposed which can accommodate standard ones like Arrhenius, power-rule, log-linear model, etc., as special cases. Later, the component lives are assumed to be independent Weibull random variables with a common shape parameter. A full Bayesian methodology is then developed by letting only the scale parameters of the Weibull component lives depend on the stress variables through the general stress translation function. Priors on all the parameters, namely the stress coefficients and the Weibull shape parameter, are assumed to be log-concave and independent of each other. This assumption is to facilitate Gibbs sampling from the joint posterior. The samples thus generated from the joint posterior is then used to obtain the Bayesian point and interval estimates of the system reliability at usage condition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives  To determine the improvement in positive predictive value of immunological failure criteria for identifying virological failure in HIV-infected children on antiretroviral therapy (ART) when a single targeted viral load measurement is performed in children identified as having immunological failure. Methods  Analysis of data from children (<16 years at ART initiation) at South African ART sites at which CD4 count/per cent and HIV-RNA monitoring are performed 6-monthly. Immunological failure was defined according to both WHO 2010 and United States Department of Health and Human Services (DHHS) 2008 criteria. Confirmed virological failure was defined as HIV-RNA >5000 copies/ml on two consecutive occasions <365 days apart in a child on ART for ≥18 months. Results  Among 2798 children on ART for ≥18 months [median (IQR) age 50 (21-84) months at ART initiation], the cumulative probability of confirmed virological failure by 42 months on ART was 6.3%. Using targeted viral load after meeting DHHS immunological failure criteria rather than DHHS immunological failure criteria alone increased positive predictive value from 28% to 82%. Targeted viral load improved the positive predictive value of WHO 2010 criteria for identifying confirmed virological failure from 49% to 82%. Conclusion  The addition of a single viral load measurement in children identified as failing immunologically will prevent most switches to second-line treatment in virologically suppressed children.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Elevated pulmonary vascular resistance (PVR) is relevant to prognosis of congestive heart failure and heart transplantation. Proof of reversibility by pharmacologic testing in potential transplantation candidates is important because it indicates a reduced probability of right ventricular failure or death in the early post-transplant period. This study aimed to clarify the possible extent of acute reversibility of elevated PVR in a large, consecutive cohort of heart transplant candidates. METHODS: This study included 208 consecutive patients (age 52 +/- 10 years, 89% men and 11% women, ejection fraction 21 +/- 9%, Vo2max 12.6 +/- 4.2 ml/kg/min) being evaluated for heart transplantation in 7 transplant centers in Germany and Switzerland. Testing was performed with increasing intravenous doses of prostaglandin E1 (PGE1; average maximum dose 173 +/- 115 ng/kg/min for at least 10 minutes) in 92 patients exhibiting a baseline PVR of > 2.5 Wood units (WU) and/or a transpulmonary gradient (TPG) of > 12 mm Hg. RESULTS: PGE1 testing lowered PVR from 4.1 +/- 2.0 to 2.1 +/- 1.1 WU (p < 0.01), increased cardiac output from 3.8 +/- 1.0 to 5.0 +/- 1.5 liters/min (p < 0.01), and decreased TPG from 14 +/- 4 to 10 +/- 3 mm Hg (p < 0.01), mean pulmonary artery pressure (PAM) from 39 +/- 9 to 29 +/- 9 mm Hg (p < 0.01) and mean pulmonary capillary wedge pressure (PCWP) from 24 +/- 7 to 19 +/- 9 mm Hg (p < 0.01). Mean aortic pressure (MAP) decreased to 85% and systemic vascular resistance (SVR) to 65% of baseline values (p < 0.01). Symptomatic systemic hypotension was not observed. For the whole population the percentage of patients with PVR > 2.5 WU was reduced from 44.2% to 10.5% with PGE1. PVR decreased in each patient; only 2 patients (1%) remained ineligible for listing because of a final PVR of > 4.0 WU. TPG, ejection fraction and male gender were independent predictors of reversibility of PVR. CONCLUSIONS: Elevated PVR in heart transplant candidates is highly reversible and can be normalized during acute pharmacologic testing with PGE1.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Brain natriuretic peptide (BNP) levels are simple and objective measures of cardiac function. These measurements can be used to diagnose heart failure, including diastolic dysfunction, and using them has been shown to save money in the emergency department setting. The high negative predictive value of BNP tests is particularly helpful for ruling out heart failure. Treatment with angiotensin-converting enzyme inhibitors, angiotensin-II receptor blockers, spironolactone, and diuretics reduces BNP levels, suggesting that BNP testing may have a role in monitoring patients with heart failure. However, patients with treated chronic stable heart failure may have levels in the normal range (i.e., BNP less than 100 pg per mL and N-terminal proBNP less than 125 pg per mL in patients younger than 75 years). Increases in BNP levels may be caused by intrinsic cardiac dysfunction or may be secondary to other causes such as pulmonary or renal diseases (e.g., chronic hypoxia). BNP tests are correlated with other measures of cardiac status such as New York Heart Association classification. BNP level is a strong predictor of risk of death and cardiovascular events in patients previously diagnosed with heart failure or cardiac dysfunction.