992 resultados para FLUORESCENT ANTIBODY TECHNIQUE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Designed as a guide for the laboratory portion of CDC Course No. 8440-C, ʻPrinciples and Bacterial Applications of Flourescent Antibody Techniquesʻ."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow cytometry-adapted fluorescent antibody to membrane antigen (FAMA) assay to detect IgG antibodies against varicella-zoster virus (VZV) was developed and tested in 62 serum samples, showing 90.32% accuracy obtained from a receiver operating characteristic (ROC) curve with a 0.9125 (95% confidence interval [CI], 0.829 to 1.00) area below the curve compared to the result with standard FAMA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood sampling on filter paper is a current practice seroepidemiological studies by indirect fluorescent antibody test (IFAT). There is, however, scant comparative information about the use of bloodspot eluates for detection of malarial IgG antibodies simultaneously by IFAT and enzyme immunoassay (ELISA). Here we report data obtained by both serological methods done on 219 bloodspot eluate samples collected in a rural community in Brazilian Amazon Basin (Alto Paraíso, Ariquemes municipality) where malaria is endemic. Plasmodium falciparum and P. vivax thick smear antigens were used in the IFAT; a detergent-soluble P. falciparum antigen was prepared for ELISA. Substantial agreement of results (Kappa coefficient k = 0.686) was observed when P. falciparum antigen was used in both tests, and IFAT titers were found to be strongly correlated ELISA antibody units (Spearman correlation coeficient rs = 0.818, p < 0.0001). Only moderate agreement (k = 0.467) between IFAT with P. vivax antigen and ELISA with P. falciparum antigen was observed. Spearman correlation coefficient value between quantitative results (IFAT titers and ELISA antibody units) in this case was numerically lowe (rs = 0.540, p < 0.0001). Our results suggest that, with P. falciparum antigen, both IFAT and ELISA performed on bloodspot eluates are equivalent for seropidemiological purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bispecific MAb was derived from the fusion of a hybridoma producing MAb CD3 with a hybridoma producing MAb L-DI (which is directed against a 41-kDa glycoprotein expressed in most gastro-intestinal and pancreatic carcinomas). Bispecific antibody molecules were isolated from parental antibody molecules by the use of hydroxylapatite-HPLC and shown to target human cytolytic T lymphocytes, irrespective of their original specificity, to specifically lyse human colon carcinoma cells. Localization studies in vivo using nude mice bearing human colon carcinoma xenografts showed significant accumulation of the HPLC-purified 125I-labelled bispecific antibodies into the tumor compared to 131I-labelled control CD3 antibody.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have recently shown that immunophotodetection of human colon carcinomas in nude mice and in patients is possible by using anti-carcinoembryonic antigen monoclonal antibodies (MAb) coupled to fluorescein. The most common clinical application of photodiagnosis has been for the detection of squamous cell carcinomas (SCC) in the upper respiratory tract, but the free dyes used have a poor tumor selectivity. We selected the known MAb E48 directed against SCC and coupled it to a fluorescent dye: indopentamethinecyanin (indocyanin). This dye has an advantage over fluorescein in that it emits a more penetrating fluorescent red signal at 667 nm after excitation with a laser ray of 640 nm. In vitro, an conjugate with an indocyanin:MAb molar ratio of 2, and an additional trace labeling with 125I, showed more than 80% of binding to cells from the SCC line A431. In vivo, when injected i.v. into nude mice bearing xenografts of the same carcinoma line, the MAb E48-(indocyanin)2 conjugate was almost as efficient as the unconjugated MAb E48 in terms of specific tumor localization: 15% of the injected dose per g of tumor at 24 h after injection and a tumor:overall normal tissue ratio of 6-8. There was no selective tumor localization of an irrelevant IgG1-(indocyanin)2 conjugate. Immunophotodetection of the s.c. SCC xenografts on mice given injections of 100 micrograms of MAb E48-(indocyanin), conjugate (representing 1 microgram of indocyanin) was performed at 24 h. Upon laser irradiation, clearly detectable red fluorescence from the indocyanin-MAb conjugate was observed specifically in the SCC xenografts across the mouse skin. In comparison, injection of 100 micrograms of a MAb E48 coupled to 2 micrograms of fluorescein gave a specific green fluorescence signal in the tumor xenografts, which was detectable, however, only after removing the mouse skin. Injection i.v. of a 15 times higher amount of free indocyanin (15 micrograms) gave a diffuse red fluorescence signal all over the mouse body with no definite increase in intensity in the tumor, indicating a lack of tumor selectivity of the free dye. The results demonstrate the possibility of broadening and improving the efficiency of tumor immunophotodiagnosis by coupling to a MAb directed against SCC, a fluorescent dye absorbing and emitting at higher wavelength than fluorescein, and thus having deeper tissue penetration and lower tissue autofluorescence. Such a demonstration opens the way to a new form of clinical immunophotodiagnosis and possibly to the development of a more specific approach to phototherapy of early bronchial carcinomas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To improve the detectability of tumors by light-induced fluorescence, the use of monoclonal antibodies (MoAb) as carriers of fluorescent molecules was studied. As a model for this approach, the biodistribution of an anticarcinoembryonic antigen (CEA) MoAb coupled to fluorescein was studied in mice bearing a human colon carcinoma xenograft. In vitro, such conjugates with fluorescein-MoAb molar ratios ranging from four to 19, doubly labeled with 125I, showed more than 82% binding to immobilized CEA. In vivo, conjugates with a fluorescein-MoAb molar ratio of ten or less resulted in a tumor uptake of more than 30% of the injected dose of radioactivity per gram tumor at 24 hours. Tumor to liver, kidney, and muscle ratios of 20, 30 and 72, respectively, were obtained 48 hours after injection of the 125I-MoAb-(fluorescein)10 conjugate. The highest fluorescence intensity was always obtained for the tumor with the anti-CEA MoAb conjugate; whereas in control mice injected with fluoresceinated control immunoglobulin G1, no detectable increase in tumor fluorescence was observed. To compare these results with a classically used dye, mice bearing the same xenografts received 60 micrograms of Photofrin II. The intensity of the fluorescence signal of the tumor with this amount of Photofrin II was eight times lower than that obtained after an injection of 442 ng of fluorescein coupled with 20 micrograms of MoAb, which gave an absolute amount of fluorescein localized in the tumor of up to 125 ng/g of tumor. These results illustrate the possibility of improving the specificity of in vivo tumor localization of dyes for laser-induced fluorescence photodetection and phototherapy by coupling them to MoAb directed against tumor markers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study determined the sensitivity and specificity of the indirect fluorescent antibody test (IFAT) and modified agglutination test (MAT) for anti-Toxoplasma gondii antibody detection by analyzing sera from 46 experimentally infected pigs. Values for sensitivity were 95.7% (confidence interval 95%: 84.0-99.2%) and for specificity 97.8% (confidence interval 95%: 87.0-99.9%) in both tests. There was an optimum agreement of results between IFAT and MAT evidenced by a Kappa test of 0.86. These results validate these tests for the detection of T. gondii infection in pigs. IFAT and MAT despite methodologies with different characteristics and readings have similar accuracy in pig serum samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVOS: Detectar anticorpos séricos anti-Giardia lamblia entre crianças atendidas em creches e estimar a freqüência de infecção por Giardia lamblia em área endêmica. MÉTODOS: Foram coletadas três amostras de fezes de cada uma das 147 crianças de três creches da rede municipal de Botucatu, SP, com idade variando de 0 a 6 anos, e as amostras foram processadas pelos métodos de sedimentação espontânea e flutuação pelo sulfato de zinco. Amostras de sangue foram obtidas da polpa digital, coletadas em papel de filtro e testadas pelos métodos de imunofluorescência indireta (IFI) e de reação imunoenzimática (Elisa) para pesquisa de IgG anti-Giardia. RESULTADOS E CONCLUSÕES: de um total de 147 crianças, 93 (63,3%) apresentaram cistos de Giardia nas fezes. Dos 147 eluatos testados, 93 (63,3%) e 100 (68%) foram positivos para Giardia em IFI e em Elisa, respectivamente. A sensibilidade de IFI foi de 82% e de Elisa, 72%. Contudo, Elisa foi menos específica (39%) do que IFI (70%). A imunofluorescência indireta apresentou maior concordância com o exame de fezes do que Elisa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An indirect fluorescent test was developed for detecting antibodies to Paracoccidioides brasiliensis using bentonite particles as antigen (Bent-IF). The bentonite particles were coated with P. brasiliensis polysaccharide antigen and tested with sera from paracoccidioidomycosis patients (36 sera), normal blood donors (32 sera) and patients with non-mycotic diseases (29 sera). The titres given by the positive sera were compared with those of complement fixation (CF), immunodiffusion (ID) and immunofluorescent test using yeast forms of the fungus as antigen (conventional-IF). All normal blood donors' sera gave a negative Bent-IF, conventional-IF, ID and CF tests. All paracoccidioidomycosis sera were reactive in conventional-IF and gave concordant results in Bent-IF. There was no correlation between CF and Bent-IF titres. 27·6% of sera from patients with non-mycotic diseases gave weak titres in both IF-tests. The present data indicate that the Bent-IF is a sensitive and simple serodiagnostic technique comparable with the conventional P. brasiliensis antibody test. © 1983.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IgG, IgM and IgA antibodies to GP43 (glycoprotein fraction of Paracoccidioides brasiliensis) were measured by ELISA in 63 samples from 23 patients with paracoccidioidomycosis before and twice after chemotherapy was started. Antibodies against P. brasiliensis were detected by indirect immunofluorescence (IF) (IgG, IgM and IgA isotypes), counterimmunoelectrophoresis (CIE) and complement fixation. Two control groups composed of 19 healthy individuals and 12 patients with other diseases (six with histoplasmosis, three with tuberculosis and three with other mycoses). The highest efficiency percentages were found with IgG and IgA- ELISA (100%), IgG-IF (96.2%), CIE (94.4%) and the lowest with CF (75.9%). Highest positive and negative predictive values (100%) were observed for IgG and IgA ELISA. IgG and IgM-ELISA antibodies are more often found in patients with acute than chronic disease (P = 0.01). Four to six months after treatment follow-up showed decreased levels of IgG and IgM-ELISA for acute cases and decreased titres of CIE for chronic cases in relation to pretreatment levels. This study suggests that IgG-ELISA anti-GP43 represents a good marker to monitor clinical response to therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunohistochemical screening for monoclonal antibodies prepared by immunization of mice with a rat osteoblastic cell population led to identification of one antibody that reacted against a small population of cells present in the soft connective tissue compartment of 21 days fetal rat calvaria. The morphology of the cells and the immunohistochemical staining characteristics (a distinct intracellular granular pattern) suggested that the antibody might be reacting specifically against mast cells. We used combined histochemistry and immunohistochemistry to further characterize this antibody, designated RCJ102. Cryosections containing calvaria bone, soft connective tissues and skin were prepared from the top of the head of 21 days fetal rats, and from adult rats cryosections of lung, muscle, adipose tissue and small intestine were prepared. Some sections were labelled by indirect immunofluorescence with RCJ102; corresponding sections were labelled histochemically with toluidine blue. There was a direct correspondence between mast cells identified histochemically and cells labelling with RCJ102 in all tissues except intestine, in which the mast cell detectable by histochemistry were not labelled by RCJ102. These results suggest that the RCJ102 antibody will be a valuable new reagent for further elucidation of the heterogeneity described between connective tissue and intestinal mucosal mast cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indirect ELISA and IFAT have been reported to be more sensitive and specific than agglutination tests. However, MAT is cheaper, easier than the others and does not need special equipment. The purpose of this study was to compare an enzyme linked immunosorbent assay using crude rhoptries of Toxoplasma gondii as coating wells (r-ELISA) with indirect fluorescence antibody test (IFAT) and modified agglutination test (MAT) to detect anti-T. gondii antibodies in sera of experimentally infected pigs. Ten mixed breed pigs between 6.5 and 7.5 weeks old were used. All pigs were negative for the presence of T. gondii antibodies by IFAT (titre < 16), r-ELISA (OD < 0.295) and MAT (titre < 16). Animals received 7 × 107 viable tachyzoites of the RH strain by intramuscular (IM) route at day 0. Serum samples were collected at days -6, 0, 7, 14, 21, 28, 35, 42, 50, and 57. IFAT detected anti-T. gondii antibodies earlier than r-ELISA and MAT. The average of antibody levels was higher at day 35 in IFAT (Log10 = 2.9) and in MAT (Log10 = 3.5), and at day 42 in r-ELISA (OD = 0.797). The antibody levels remained high through the 57th day after inoculation in MAT, and there was a decrease tendency in r-ELISA and IFAT. IFAT was used as gold standard and r-ELISA demonstrated a higher prevalence (73.3%), sensitivity (94.3%), negative predictive value (83.3%), and accuracy (95.6%) than MAT. Kappa agreements among tests were calculated, and the best results were shown by r-ELISA × IFAT (κ = 0.88, p < 0.001). Cross-reaction with Sarcocystis miescheriana was investigated in r-ELISA and OD mean was 0.163 ± 0.035 (n = 65). Additionally, none of the animals inoculated with Sarcocystis reacted positively in r-ELISA. Our results indicate that r-ELISA could be a good method for serological detection of T. gondii infection in pigs. © 2005 Elsevier Inc. All rights reserved.