81 resultados para FLUIDIZATION
Resumo:
Changes in the physical properties (such as particle density, bulk density of the bed, shrinkage and bed porosity) of fresh green bean particulates were investigated during drying. Three length:diameter ratios (1:1, 2:1 and 3:1) were considered, using drying conditions of 50 +/- 2 degrees C and 13 +/- 2% relative humidity in a heat pump dehumidifier system. The fluidization behaviour was also evaluated at 10 levels of moisture content. The fluidization experiments demonstrated that the minimum fluidization velocity decreases as the drying proceeds due to the reduced moisture content and changes in the physical properties of the bean particulates. Empirical relationships of the following nature were developed for the change in shrinkage [VR = 1 - Be-kMR], particle density [rho(p) = A + BMR + C (exp)(-D MR)], bulk density [rho(b) = a(1) + b(1)MR + c(1)MR(2)] and bed porosity [epsilon = a(2) + b(2)MR + c(2)MR(2)] with the moisture content during fluidized bed drying.
Resumo:
Depending on the size and shape of the materials, methods employed to achieve effective fluidization during fluid bed drying varies from use of simple hole distributors for small, light weight materials to special techniques for lager and/or moist materials. This paper reviews common air distributors used in fluidized bed drying of food particulates. Also it reviews special methods of fluidizing larger irregular food particulates.
Resumo:
Treatment of Escherichia coli with non-lethal doses of heat or benzyl alcohol (BA) causes transient membrane fluidization and permeabilization, and induces the rapid transcription of heat-shock genes in a sigma32-dependent manner. This early response is followed by a rapid adaptation (priming) of the cells to otherwise lethal elevated temperature, in strong correlation with an observed remodeling of the composition and alkyl chain unsaturation of membrane lipids. The acquisition of cellular thermotolerance in BA-primed cells is unrelated to protein denaturation and is not accompanied by the formation of major heat-shock proteins, such as GroEL and DnaK. This suggests that the rapid remodeling of membrane composition is sufficient for the short-term bacterial thermotolerance.
Resumo:
Changes in the dynamics of sediment transport in a Mediterranean lake (sediment fluidization events) are linked to atmospheric circulations patterns (trough monthly precipitation). In the basins of Lake Banyoles, located in the northeast of Spain, water enters mainly through subterranean springs, and associated fluctuations in the vertical migration of sediment distribution (fluidization events) present episodic behavior as a result of episodic rainfall in the area. The initiation of the fluidization events takes place when the monthly rainfall is ∼2.7 times greater than the mean monthly rainfall of the rainiest months in the area, especially in spring (April and May), October, and December. The duration of these events is found to be well correlated with the accumulated rainfall of the preceding 10 months before the process initiation. The rainfall, in turn, is mainly associated with six atmospheric circulation patterns among the 19 fundamental circulations that emerged in an earlier study focused on significant rainfall days in Mediterranean Spain. Among them, accentuated surface lows over the northeast of Spain, general northeasterly winds by low pressure centered to the east of Balearic Islands and short baroclinic waves over the Iberian Peninsula, with easterly flows over the northeastern coast of Spain, are found the most relevant atmospheric circulations that drive heavy rainfall events
Resumo:
Every adherent eukaryotic cell exerts appreciable traction forces upon its substrate. Moreover, every resident cell within the heart, great vessels, bladder, gut or lung routinely experiences large periodic stretches. As an acute response to such stretches the cytoskeleton can stiffen, increase traction forces and reinforce, as reported by some, or can soften and fluidize, as reported more recently by our laboratory, but in any given circumstance it remains unknown which response might prevail or why. Using a novel nanotechnology, we show here that in loading conditions expected in most physiological circumstances the localized reinforcement response fails to scale up to the level of homogeneous cell stretch; fluidization trumps reinforcement. Whereas the reinforcement response is known to be mediated by upstream mechanosensing and downstream signaling, results presented here show the fluidization response to be altogether novel: it is a direct physical effect of mechanical force acting upon a structural lattice that is soft and fragile. Cytoskeletal softness and fragility, we argue, is consistent with early evolutionary adaptations of the eukaryotic cell to material properties of a soft inert microenvironment.
Resumo:
The purpose of this work is to predict the minimum fluidization velocity Umf in a gas-solid fluidized bed. The study was carried out with an experimental apparatus for sand particles with diameters between 310μm and 590μm, and density of 2,590kg/m3. The experimental results were compared with numerical simulations developed in MFIX (Multiphase Flow with Interphase eXchange) open source code [1], for three different sizes of particles: 310mum, 450μm and 590μm. A homogeneous mixture with the three kinds of particles was also studied. The influence of the particle diameter was presented and discussed. The Ergun equation was also used to describe the minimum fluidization velocity. The experimental data presented a good agreement with Ergun equation and numerical simulations. Copyright © 2011 by ASME.
Resumo:
Includes bibliography.
Resumo:
Changes in fluidization behaviour of green peas particulates with change in moisture content during drying were investigated using a fluidized bed dryer. All drying experiments were conducted at 50 + 2 0C and 13 + 2 % RH using a heat pump dehumidifier system. Fluidization experiments were undertaken for the bedheights of 100, 80, 60 and 40 mm and at 10 moisture content levels. Fluidization behaviour was best fitted to the linear model of Umf = A + B m. A generalized model was also formulated using the height variation. Also generalized equation and Ergun equation was used to compare minimum fluidization velocity. Copyright ©2006 The Berkeley Electronic Press. All rights reserved.
Resumo:
Application of mechanical vibration to aid fluidization and to improve heat, mass and momentum transfer are usual processes in agricultural industry and it has found nowadays extensive applications in particle processing of materials difficult-to-fluidized. Equations and experimental data found in literature for the aerodynamics characteristics of vibro-fluidized beds are presented and discussed, emphasizing the vibration effect in the bed.
Resumo:
The spouted and fluidized bed technologies are usually employed in operations of drying, coating and granulation of particles by the chemical and pharmaceutical industries. The use of these techniques in agronomy is limited to the treatment of some species of seeds. In this work, the objective was to analyse the fluid-dynamics of fluidized and spouted beds when broccoli (Brassica oleracea L. var. Italica) seeds are used and also to verify the influence on seed germination after 60 min of seed exposition to spouting or fluidization, at room temperature. The fluid-dynamics was defined by the measurements of the bed pressure drop as a function of the air flow rate for different seeds loads. The experimental conditions were based on the physical properties of the seeds and were limited by the apparatus dimensions. The cone-cylindrical bed was constructed in plexyglass to permit flow visualization. The values of the parameters: maximum pressure drop, minimum spouting flow rate and pressure drop, and stable spout pressure drop were experimentally obtained from the fluid-dynamic analysis and were compared with the values calculated by empirical equations found in the literature. The same procedure was carried out with the fluidized bed and the important parameters for this regime were the air velocity and the bed pressure drop at minimum fluidization. The analysis of seed germination indicated that no damage was caused to the seeds by the spout or fluidization processes.
Resumo:
The fluidized bed reactor has successfully been used to perform biotechnological processes addressed to the production of high added value. The present work evaluates hydrodynamic parameters of a bench-scale fluidized bed reactor with cells of the yeast Candida guilliermondii immobilized either in calcium alginate beads or in polyvinyl alcohol (PVA). The effects of the following variables on cell immobilization were evaluated at 30 degrees C and feeding a synthetic medium containing 50 g L-1 xylose: total particle density (cells plus support), terminal velocity, particle drag force, minimum fluidization velocity and bed porosity. According to the results obtained, the reactor was shown to operate like a fixed-bed bioreactor at xi < 0.5 and a fluidized bed bioreactor at xi > 0.5. The maximum flow rate needed to obtain maximum bed fluidization in the reactor was equal to the terminal velocity of the immobilized cell particles. Particles of cells immobilized within these supports showed values of drag coefficient lower than those reported for other high-density supports. The evaluation of these hydrodynamic characteristics lead to an adequate bed fluidization inside the reactor, thus improving oxygen transference and availability in the fermentation medium, making the process more viable for future scale-up. (c) 2008 Society of Chemical Industry.
Resumo:
Fluid dynamic analysis is an important branch of several chemical engineering related areas, such as drying processes and chemical reactors. However, aspects concerning fluid dynamics in wastewater treatment bioreactors still require further investigation, as they highly influence process efficiency. Therefore, it is essential to evaluate the influence of biofilm on the reactor fluid dynamic behavior, through the analysis of a few important parameters, such as minimum fluidization velocity, bed expansion and porosity, and particle terminal velocity. The main objective of the present work was to investigate the fluid dynamics of an anaerobic fluidized bed reactor, having activated carbon particles as support media for biomass immobilization. Reactor performance was tested using synthetic residual water, which was prepared using the solution employed in BOD determination. The results showed that the presence of immobilized biomass increased particle density and altered the main fluid dynamic parameters investigated.
Resumo:
Hydrodynamic studies were conducted in a semi-cylindrical spouted bed column of diameter 150 mm, height 1000 mm, conical base included angle of 60 degrees and inlet orifice diameter 25 mm. Pressure transducers at several axial positions were used to obtain pressure fluctuation time series with 1.2 and 2.4 mm glass beads at U/U-ms from 0.3 to 1.6, and static bed depths from 150 to 600 mm. The conditions covered several flow regimes (fixed bed, incipient spouting, stable spouting, pulsating spouting, slugging, bubble spouting and fluidization). Images of the system dynamics were also acquired through the transparent walls with a digital camera. The data were analyzed via statistical, mutual information theory, spectral and Hurst`s Rescaled Range methods to assess the potential of these methods to characterize the spouting quality. The results indicate that these methods have potential for monitoring spouted bed operation.
Resumo:
OctVCE is a cartesian cell CFD code produced especially for numerical simulations of shock and blast wave interactions with complex geometries, in particular, from explosions. Virtual Cell Embedding (VCE) was chosen as its cartesian cell kernel for its simplicity and sufficiency for practical engineering design problems. The code uses a finite-volume formulation of the unsteady Euler equations with a second order explicit Runge-Kutta Godonov (MUSCL) scheme. Gradients are calculated using a least-squares method with a minmod limiter. Flux solvers used are AUSM, AUSMDV and EFM. No fluid-structure coupling or chemical reactions are allowed, but gas models can be perfect gas and JWL or JWLB for the explosive products. This report also describes the code’s ‘octree’ mesh adaptive capability and point-inclusion query procedures for the VCE geometry engine. Finally, some space will also be devoted to describing code parallelization using the shared-memory OpenMP paradigm. The user manual to the code is to be found in the companion report 2007/13.
Resumo:
OctVCE is a cartesian cell CFD code produced especially for numerical simulations of shock and blast wave interactions with complex geometries. Virtual Cell Embedding (VCE) was chosen as its cartesian cell kernel as it is simple to code and sufficient for practical engineering design problems. This also makes the code much more ‘user-friendly’ than structured grid approaches as the gridding process is done automatically. The CFD methodology relies on a finite-volume formulation of the unsteady Euler equations and is solved using a standard explicit Godonov (MUSCL) scheme. Both octree-based adaptive mesh refinement and shared-memory parallel processing capability have also been incorporated. For further details on the theory behind the code, see the companion report 2007/12.