889 resultados para FLEXURAL PSORIASIS
Resumo:
Although therapy with tumor necrosis factor-alpha inhibitors (anti-TNF) provides beneficial effects in different immune inflammatory disorders, paradoxical cases of anti-THE-induced psoriasis have increasingly been reported, mostly in the setting of rheumatologic diseases. To date, less than 50 cases of infliximab-induced psoriasis in inflammatory bowel disease patients have been described. The present report was aimed at describing two new cases of infliximab-induced psoriasis during therapy for Crohn's disease and at carrying out a review on this intriguing phenomenon. (C) 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: Efalizumab is a human anti-CD11a monoclonal antibody used in the treatment of patients with moderate to severe plaque psoriasis. Some of the patients develop new papular lesions during treatment, which are predominantly located in the flexural regions. OBSERVATION: Four patients with recalcitrant psoriasis undergoing treatment with efalizumab presented with erythematous, partly scaly papules and small plaques on previously unaffected areas after 4 to 10 weeks of efalizumab therapy. Tissue sections of biopsy specimens were stained with hematoxylin-eosin, and immunohistochemical staining was performed using monoclonal antibodies against CD3, CD4, CD8, T-cell-restricted intracellular antigen 1, granzyme B, neutrophil elastase, CD68, CD1a, CD11c, HLA-DR, CD25, CD20, and CD56. Histopathological and immunohistochemical examination of the lesions showed features consistent with psoriasis and activation of various leukocyte subtypes including T cells, dendritic cells, macrophages, and neutrophils. CONCLUSIONS: Papular eruptions appearing during efalizumab therapy represent new psoriatic lesions and could be referred to as efalizumab-associated papular psoriasis (EAPP). They usually do not necessitate termination of efalizumab therapy and may optionally be treated with topical corticosteroids. Dermatologists should be aware of these lesions and inform their patients accordingly.
Resumo:
Chemokines may contribute to local and systemic inflammation in patients with psoriasis. Previous studies have demonstrated the importance of chemokine ligands and receptors in the recruitment of T cells into psoriatic lesional skin and synovial fluid. The aim of this study was to evaluate the levels of Th1-related chemokines in psoriasis and to investigate any association with disease severity. We quantified serum levels of CXCL9, CXCL10 and CXCL16 and the frequencies of CD4+CXCR3+ T lymphocytes through ELISA and flow cytometry, respectively. A total of 38 patients with psoriasis and 33 controls were included. There were no significant differences in chemokine levels between psoriasis and control groups. Patients with psoriatic arthritis had lower median level of CXCL10 when compared with controls (p=0.03). There were no significant correlations between serum chemokines analyzed and disease severity. Frequencies of CD4+CXCR3+ T cells were lower in patients with psoriasis than in controls (p<0.01). A sensitivity analysis excluding patients on systemic therapy yielded similar results. Serum concentrations of CXCL9, CXCL10 and CXCL16 were not increased in the psoriasis group or correlated with disease severity. Systemic levels of chemokine ligands do not seem to be sensitive biomarkers of disease activity or accurate parameters to predict response to therapy. Frequencies of CD4+CXCR3+ T cells were decreased in the peripheral blood of psoriasis patients, possibly due to recruitment to inflammatory lesions.
Resumo:
Fluorinated denture base acrylic resins can present more stable physical properties when compared with conventional polymers. This study evaluated the incorporation of a fluoroalkyl methacrylate (FMA) mixture in a denture base material and its effect on roughness and flexural strength. A swelling behavior assessment of acrylic resin specimens (n=3, per substance) after 12 h of FMA or methyl methacrylate (MMA) immersion was conducted to determine the solvent properties. Rectangular specimens (n=30) were allocated to three groups, according to the concentration of FMA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (control), 10% and 20% (v/v). Acrylic resin mixed with concentrations of 25% or more did not reach the dough stage and was not viable. The surface roughness and flexural strength of the specimens were tested. Variables were analyzed by ANOVA and Tukey's test (a=0.05). Immersion in FMA produced negligible swelling, and MMA produced obvious swelling and dissolution of the specimens. Surface roughness at concentrations of 0%, 10% and 20% were: 0.25 ± 0.04, 0.24 ± 0.04, 0.22 ± 0.03 mm (F=1.78; p=0.189, not significant). Significant differences were found for flexural strength (F=15.92; p<0.001) and modulus of elasticity (F=7.67; p=0.002), with the following results: 96 ± 6, 82 ± 5, 84 ± 6 MPa, and 2,717 ± 79, 2,558 ± 128, 2574 ± 87 MPa, respectively. The solvent properties of FMA against acrylic resin are weak, which would explain why concentrations over 20% were not viable. Surface changes were not detected after the incorporation of FMA in the denture base acrylic resin tested. The addition of FMA into denture base resin may lower the flexural strength and modulus of elasticity, regardless of the tested concentration.
Resumo:
The purpose of this study was to evaluate the flexural strength of a direct composite, for indirect application, that received heat treatment, with or without investment. One indirect composite was used for comparison. For determination of the heat treatment temperature, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) were performed, considering the initial weight loss temperature and glass transition temperature (Tg). Then, after photoactivation (600 mW/cm² - 40 s), the specimens (10 x 2 x 2 mm) were heat-treated following these conditions: 170ºC for 5, 10 or 15 min, embedded or not embedded in investment. Flexural strength was assessed as a means to evaluate the influence of different heat treatment periods and investment embedding on mechanical properties. The data were analyzed by ANOVA and Tukey's test (α = 0.05). TGA showed an initial weight loss temperature of 180ºC and DSC showed a Tg value of 157°C. Heat treatment was conducted in an oven (Flli Manfredi, Italy), after 37°C storage for 48 h. Flexural strength was evaluated after 120 h at 37°C storage. The results showed that different periods and investment embedding presented similar statistical values. Nevertheless, the direct composite resin with treatments presented higher values (178.7 MPa) compared to the indirect composite resin (146.0 MPa) and the same direct composite submitted to photoactivation only (151.7 MPa). Within the limitations of this study, it could be concluded that the heat treatment increased the flexural strength of the direct composite studied, leading to higher mechanical strength compared to the indirect composite.
Resumo:
The objective of this study was to evaluate the flexural strength (σf) and hardness (H) of direct and indirect composites, testing the hypotheses that direct resin composites produce higher σf and H values than indirect composites and that these properties are positively related. Ten bar-shaped specimens (25 mm x 2 mm x 2 mm) were fabricated for each direct [D250 - Filtek Z250 (3M-Espe) and D350 - Filtek Z350 (3M-Espe)] and indirect [ISin - Sinfony (3M-Espe) and IVM - VitaVM LC (Vita Zahnfabrik)] materials, according to the manufacturer's instructions and ISO4049 specifications. The σf was tested in three-point bending using a universal testing machine (EMIC DL 2000) at a crosshead speed of 0.5 mm/min (ISO4049). Knoop hardness (H) was measured on the specimens' fragments resultant from the σf test and calculated as H = 14.2P/l², where P is the applied load (0.1 kg; dwell time = 15 s) and l is the longest diagonal of the diamond shaped indent (ASTM E384). The data were statistically analyzed using Anova and Tukey tests (α = 0.05). The mean σf and standard deviation values (MPa) and statistical grouping were: D250 - 135.4 ± 17.6a; D350 - 123.7 ± 11.1b; ISin - 98.4 ± 6.4c; IVM - 73.1 ± 4.9d. The mean H and standard deviation values (kg/mm²) and statistical grouping were: D250 - 98.12 ± 1.8a; D350 - 86.5 ± 1.9b; ISin - 28.3 ± 0.9c; IVM - 30.8 ± 1.0c. The direct composite systems examined produce higher mean σf and H values than the indirect composites, and the mean values of these properties were positively correlated (r = 0.91), confirming the study hypotheses.
Resumo:
This study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.
Resumo:
This paper focuses on the flexural behavior of RC beams externally strengthened with Carbon Fiber Reinforced Polymers (CFRP) fabric. A non-linear finite element (FE) analysis strategy is proposed to support the beam flexural behavior experimental analysis. A development system (QUEBRA2D/FEMOOP programs) has been used to accomplish the numerical simulation. Appropriate constitutive models for concrete, rebars, CFRP and bond-slip interfaces have been implemented and adjusted to represent the composite system behavior. Interface and truss finite elements have been implemented (discrete and embedded approaches) for the numerical representation of rebars, interfaces and composites.
Resumo:
In this paper, a computational tool concerning the computation of flexural and fracture toughness of cement based composites is presented. Firstly, RILEM`s (Reunion Internationale des Laboratoires d`Essais de Materiaux) recommendations related to the analysis of FRC in three-point bend tests are discussed in their relevant aspects regarding the computational implementations. The determination of other mechanical properties such as the Young modulus has been added to the program. Taking this into account, a new formulation based on displacements is used. In the second part of the paper, the determination of fracture properties of concrete, such as the fracture energy, G(F) , and the fracture toughness, K-IC(S), is discussed regarding the computational strategies used in the implementations. Several features whereby anterior data can be reanalyzed, obtained from other standards and recommendations, have been incorporated into the program, therefore allowing comparative studies and back analysis activities.
Resumo:
The effects of temperature on the fast fracture behavior of aluminum nitride with 5 wt% Y(2)O(3) ceramic were investigated. Four-point flexural strength and fracture toughness were measured in air at several temperatures (30-1,300 A degrees C). The flexural strength gradually decreased with the increase of temperature up to 1,000 A degrees C due to the change in the fracture mode from transgranular to intergranular, and then became almost constant up to 1,300 A degrees C. Two main flaw types as fracture origin were identified: small surface flaw and large pores. The volume fraction of the large pores was only 0.01%; however, they limited the strength on about 50% of the specimens. The fracture toughness decreased slightly up to 800 A degrees C controlled by the elastic modulus change, and then decreased significantly at 1,000 A degrees C due to the decrease in the grain-boundary toughness. Above 1,000 A degrees C, the fracture toughness increased significantly, and at 1,300 A degrees C, its value was close to that measured at room temperature.
Resumo:
The occurrence of foliated rock masses is common in mining environment. Methods employing continuum approximation in describing the deformation of such rock masses possess a clear advantage over methods where each rock layer and each inter-layer interface (joint) is explicitly modelled. In devising such a continuum model it is imperative that moment (couple) stresses and internal rotations associated with the bending of the rock layers be properly incorporated in the model formulation. Such an approach will lead to a Cosserat-type theory. In the present model, the behaviour of the intact rock layer is assumed to be linearly elastic and the joints are assumed to be elastic-perfectly plastic. Condition of slip at the interfaces are determined by a Mohr-Coulomb criterion with tension cut off at zero normal stress. The theory is valid for large deformations. The model is incorporated into the finite element program AFENA and validated against an analytical solution of elementary buckling problems of a layered medium under gravity loading. A design chart suitable for assessing the stability of slopes in foliated rock masses against flexural buckling failure has been developed. The design chart is easy to use and provides a quick estimate of critical loading factors for slopes in foliated rock masses. It is shown that the model based on Euler's buckling theory as proposed by Cavers (Rock Mechanics and Rock Engineering 1981; 14:87-104) substantially overestimates the critical heights for a vertical slope and underestimates the same for sub-vertical slopes. Copyright (C) 2001 John Wiley & Sons, Ltd.
Resumo:
Tuberculosis has emerged as a major concern in patients with immuno-mediated diseases, including psoriasis, undergoing treatment with biologicals. However, it is not known whether the chronically activated immune system of psoriasis patients interferes with their Mycobacterium tuberculosis (Mtb)-specific immunity, especially in tuberculosis-endemic areas like Brazil. We evaluated T-cell responses to a Mtb lysate and to the recombinant Mtb proteins ESAT-6 and Ag85B of tuberculin skin test (TST) positive and TST negative patients with severe or mild/moderate, untreated psoriasis in three different assays: lymphocyte proliferation, enzyme immunoassay for interferon (IFN)-gamma and interleukin (IL)-10 production by peripheral blood mononuclear cells and overnight enzyme immunospot (ELISpot) for enumerating IFN-gamma-secreting cells. In our cohort, a low proportion (29%) of the severe psoriasis patients tested were TST-positive. IFN-gamma and IL-10 secretion and T-cell proliferation to Mtb antigens were reduced in TST-negative but not in TST-positive patients with severe psoriasis when compared to healthy controls with the same TST status. Similarly, severe psoriasis patients had decreased cytokine secretion and proliferative response to phytohemagglutinin. However, most psoriasis patients and healthy controls showed detectable numbers of IFN-gamma-secreting effector-memory T-cells in response to Mtb antigens by ELISpot. TST-negative, mild/moderate psoriasis patients had responses that were mostly intermediary between TST-negative controls and severe psoriasis patients. Thus, patients with severe psoriasis possess decreased anti-Mtb central memory T-cell responses, which may lead to false-negative results in the diagnosis of TB infection, but retain T-cell memory-effector activity against Mtb antigens. We hypothesize that the latter may confer some protection against tuberculosis reactivation.
Resumo:
Objectives. This study was aimed to test if the frequency of oral lesions bears statistical correlation or not with the condition of cutaneous psoriasis. Study design. Two groups were examined, one made up of 166 patients with skin psoriasis and the other with the same number of individuals with a negative history of skin diseases (control group), matched by age, race, and sex. Patients with psoriasis were grouped according to their having localized or generalized forms of the disease. The oral mucosa was thoroughly examined in both groups. Data were analyzed using chi-square test, Fisher`s test, the odds ratio (OR) with a 95% confidence interval (CI), and the Ryan-Holm step-down Bonferroni procedure. The overall significance was set at P <= 0.05. Results. The oral lesions significantly associated with psoriasis were fissured tongue (FT, OR=2.7; 95% CI: 1.3-5.6), and geographic tongue (GT, OR=5.0; 95% CI: 1.5-16.8). Other factors analyzed, such as topical and/or systemic medication for treatment of psoriasis versus nontreated patients, and localized versus generalized forms of psoriasis presented no statistical association with the frequency of FT or GT lesions (P > 0.05). Conclusions. Patients with psoriasis presented no specific oral lesion different from those seen in the control group. Although further investigation is warranted to establish whether or not either FT or GT can be characterized as an oral expression of psoriasis, the present investigation did find for both these types of lesions that the frequency of each bore a statistically significant relation with the presence of cutaneous psoriasis.
Resumo:
Purpose: To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength. Materials and Methods: Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mu m) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Sackingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukey`s test (alpha = 0.05). Results: Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p = 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted. Conclusion: Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.