1000 resultados para Extractor solution
Resumo:
The aim of the present work was to develop and optimize a method for determination of bioavailable phosphorus in samples of feces and fish feed using ultrasound extraction and subsequent quantification by visible spectrophotometry. Using as extractor solution HNO(3) 0.50 mol L(-1), the great conditions of extraction established were: sample mass - 100 mg, samples granulometry - < 60 mu m, sonification time - five cycles of 40 s and ultrasound potency - 136 W. The proposed method was applied in studies of digestibility of this nutrient in different feeds used in diets of juvenile of Nile tilapia.
Resumo:
The study of growth and uptake of nutrients is important to determine the times of increased demand in order to schedule the fertigation. The present research was developed with the objective of evaluating the effects of different levels of electrical conductivity on growth and accumulation of nutrients in chrysanthemum plants under greenhouse conditions. The electrical conductivity levels on the applied solution were 1.42, 1.65, 1.89, 2.13 and 2.36 dS m-1 (bud vegetative stage); 1.71, 1.97, 2.28, 2.57 and 2.85 dS m-1 (bud stage). The dry mass of the aerial portion of the plant and the contents of macronutrients and micronutrients were determined every 14 days. The nutrient accumulation in chrysanthemum plant showed similar trend as compared to dry matter accumulation. The nutrients presented the following order of absorption: K>N>Ca>Mg>P>S (1425, 892, 184, 150, 110 and 59 mg plant-1) and Fe>Zn>B>Mn>Cu (2254, 2219, 1725, 1287, 210 μg plant-1). The content of most nutrients increased with increase in electrical conductivity of the solution, without salt effect up to EC of 2.85 dS m-1.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Proteção de Plantas) - FCA
Resumo:
Throughout history, developments in medicine have aimed to improve patient quality of life, and reduce the trauma associated with surgical treatment. Surgical access to internal organs and bodily structures has been traditionally via large incisions. Endoscopic surgery presents a technique for surgical access via small (1 Omm) incisions by utilising a scope and camera for visualisation of the operative site. Endoscopy presents enormous benefits for patients in terms of lower post operative discomfort, and reduced recovery and hospitalisation time. Since the first gall bladder extraction operation was performed in France in 1987, endoscopic surgery has been embraced by the international medical community. With the adoption of the new technique, new problems never previously encountered in open surgery, were revealed. One such problem is that the removal of large tissue specimens and organs is restricted by the small incision size. Instruments have been developed to address this problem however none of the devices provide a totally satisfactory solution. They have a number of critical weaknesses: -The size of the access incision has to be enlarged, thereby compromising the entire endoscopic approach to surgery. - The physical quality of the specimen extracted is very poor and is not suitable to conduct the necessary post operative pathological examinations. -The safety of both the patient and the physician is jeopardised. The problem of tissue and organ extraction at endoscopy is investigated and addressed. In addition to background information covering endoscopic surgery, this thesis describes the entire approach to the design problem, and the steps taken before arriving at the final solution. This thesis contributes to the body of knowledge associated with the development of endoscopic surgical instruments. A new product capable of extracting large tissue specimens and organs in endoscopy is the final outcome of the research.
Resumo:
The based membrane extraction of Th4+ and Yb3+ was studied in HBTMPP-heptane using a hollow fibber membrane. The separation method of Th4+ and Yb3+ was proposed by kinetics competition. The separation operation of Th4+ and Yb3+ mixture was carried out by two successive extraction and stripping simultaneously. The concentration ratio of Th4+ to Yb3+ is 16.74 in the stripping solution. The recovery and purity of Th4+ are 71.6% and 95.74% respectively.
Resumo:
Fleck and Johnson (Int. J. Mech. Sci. 29 (1987) 507) and Fleck et al. (Proc. Inst. Mech. Eng. 206 (1992) 119) have developed foil rolling models which allow for large deformations in the roll profile, including the possibility that the rolls flatten completely. However, these models require computationally expensive iterative solution techniques. A new approach to the approximate solution of the Fleck et al. (1992) Influence Function Model has been developed using both analytic and approximation techniques. The numerical difficulties arising from solving an integral equation in the flattened region have been reduced by applying an Inverse Hilbert Transform to get an analytic expression for the pressure. The method described in this paper is applicable to cases where there is or there is not a flat region.