1000 resultados para Erro de medida


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we study the survival cure rate model proposed by Yakovlev et al. (1993), based on a competing risks structure concurring to cause the event of interest, and the approach proposed by Chen et al. (1999), where covariates are introduced to model the risk amount. We focus the measurement error covariates topics, considering the use of corrected score method in order to obtain consistent estimators. A simulation study is done to evaluate the behavior of the estimators obtained by this method for finite samples. The simulation aims to identify not only the impact on the regression coefficients of the covariates measured with error (Mizoi et al. 2007) but also on the coefficients of covariates measured without error. We also verify the adequacy of the piecewise exponential distribution to the cure rate model with measurement error. At the end, model applications involving real data are made

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to estimate the regressions calibration for the dietary data that were measured using the quantitative food frequency questionnaire (QFFQ) in the Natural History of HPV Infection in Men: the HIM Study in Brazil. A sample of 98 individuals from the HIM study answered one QFFQ and three 24-hour recalls (24HR) at interviews. The calibration was performed using linear regression analysis in which the 24HR was the dependent variable and the QFFQ was the independent variable. Age, body mass index, physical activity, income and schooling were used as adjustment variables in the models. The geometric means between the 24HR and the calibration-corrected QFFQ were statistically equal. The dispersion graphs between the instruments demonstrate increased correlation after making the correction, although there is greater dispersion of the points with worse explanatory power of the models. Identification of the regressions calibration for the dietary data of the HIM study will make it possible to estimate the effect of the diet on HPV infection, corrected for the measurement error of the QFFQ.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo foi estimar as regressões de calibração dos dados dietéticos mensurados pelo questionário quantitativo de freqüência alimentar (QQFA) utilizado no Natural History of HPV Infection in Men: o Estudo HIM. Uma amostra de 98 indivíduos do estudo HIM respondeu, por meio de entrevista, a um QQFA e três recordatórios de 24 horas (R24h). A calibração foi feita por meio de análise de regressão linear, tendo os R24h como variável dependente e o QQFA como variável independente. Idade, índice de massa corporal, atividade física, renda e escolaridade foram utilizadas como variáveis de ajuste nos modelos. As médias geométricas dos R24h e do QQFA corrigido pela calibração são estatisticamente iguais. Os gráficos de dispersão entre os instrumentos demonstraram aumento da correlação após a correção dos dados, porém observa-se maior dispersão dos pontos de acordo com a piora do poder explicativo dos modelos. A identificação das regressões de calibração dos dados dietéticos do estudo HIM permitirá a estimativa do efeito da dieta sobre a infecção por HPV, corrigida pelo erro de medida do QQFA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Estratégias metodológicas vêm sendo desenvolvidas para minimizar o efeito do erro de medida da dieta. O objetivo do estudo foi descrever a aplicação de uma estratégia para correção da informação dietética pelo erro de medida. MÉTODOS: Foram obtidos dados de consumo alimentar pela aplicação do Questionário de Freqüência Alimentar a 79 adolescentes do Município de São Paulo em 1999. Os dados dietéticos obtidos foram corrigidos por meio de regressão linear, após o ajuste pela energia usando-se o método dos resíduos. O método de referência utilizado foi o recordatório de 24 horas, aplicado em três momentos distintos. RESULTADOS: Os valores corrigidos aproximaram-se dos valores de referência. O fator de correção lambda foi de 0,89 para energia. Para os macronutrientes, os fatores foram de 0,41; 0,22 e 0,20, para carboidratos, lipídios e proteínas, respectivamente. CONCLUSÕES: As médias e desvios-padrão dos valores corrigidos denotam que houve uma correção do erro de medida. Apesar disso, debate-se o desempenho desses métodos, que são notoriamente imperfeitos quando seus pressupostos teóricos não são atendidos, o que é comum nos estudos da dieta que usam instrumentos de medida baseados no relato dos indivíduos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta dissertação de mestrado em economia foi motivada por uma questão complexa bastante estudada na literatura de economia política nos dias de hoje: as formas como campanhas políticas afetam votação em uma eleição. estudo procura modelar mercado eleitoral brasileiro para deputados federais senadores. Através de um modelo linear, conclui-se que os gastos em campanha eleitoral são fatores decisivos para eleição de um candidato deputado federal. Após reconhecer que variável que mede os gastos em campanha possui erro de medida (devido ao famoso "caixa dois", por exemplo), além de ser endógena uma vez que candidatos com maiores possibilidades de conseguir votos conseguem mais fontes de financiamento -, modelo foi estimado por variáveis instrumentais. Para senadores, utilizando modelos lineares modelos com variável resposta binaria, verifica-se também importância, ainda que em menor escala, da campanha eleitoral, sendo que um fator mais importante para corrida ao senado parece ser uma percepção priori da qualidade do candidato.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste trabalho é verificar se o ajustamento das condições de paridade de juros por expectativa do mercado (paridade descoberta) e por prêmios de risco (paridades coberta e descoberta) leva à validação da relação de não-arbitragem subjacente, ou pelo menos a resultados econométricos mais próximos de sua validação. Para isso, combinamos taxas de retornos de instrumentos de renda fixa domésticos e norte-americanos e aplicamos o arcabouço econométrico de séries de tempo. Como primeiro passo de investigação, aplicamos a paridade de juros (descoberta e coberta) na sua forma tradicional. No passo seguinte aplicamos os testes econométricos às condições de paridade ajustadas por um prêmio de risco. No caso da PDJ, não obtivemos resultados satisfatórios, mesmo ajustando pelos prêmios de risco. Esse ajuste propiciou uma mudança nos sinais dos coeficientes na direção correta, mas a magnitude do coeficiente da desvalorização cambial efetiva passou a destoar bastante da magnitude das outras séries. Apesar de termos obtido a validade da PCJ na forma tradicional, não esperaríamos este resultado, pois isso implicaria que o prêmio de risco país seria nulo para este período. Ajustando a PCJ pelo prêmio de risco de não-pagamento passa-se a não obter co integração entre as séries, ou seja, o prêmio de risco de não-pagamento teria um comportamento independente do prêmio futuro e do diferencial de juros. As possíveis causas para a não obtenção dos resultados esperados são: intervalo amostraI menor que 3 anos, erro de medida dos dados de survey ou tentativa do Banco Central de controlar a taxa de câmbio nominal e as taxas de juros domésticas simultaneamente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta dissertação concentra-se nos processos estocásticos espaciais definidos em um reticulado, os chamados modelos do tipo Cliff & Ord. Minha contribuição nesta tese consiste em utilizar aproximações de Edgeworth e saddlepoint para investigar as propriedades em amostras finitas do teste para detectar a presença de dependência espacial em modelos SAR (autoregressivo espacial), e propor uma nova classe de modelos econométricos espaciais na qual os parâmetros que afetam a estrutura da média são distintos dos parâmetros presentes na estrutura da variância do processo. Isto permite uma interpretação mais clara dos parâmetros do modelo, além de generalizar uma proposta de taxonomia feita por Anselin (2003). Eu proponho um estimador para os parâmetros do modelo e derivo a distribuição assintótica do estimador. O modelo sugerido na dissertação fornece uma interpretação interessante ao modelo SARAR, bastante comum na literatura. A investigação das propriedades em amostras finitas dos testes expande com relação a literatura permitindo que a matriz de vizinhança do processo espacial seja uma função não-linear do parâmetro de dependência espacial. A utilização de aproximações ao invés de simulações (mais comum na literatura), permite uma maneira fácil de comparar as propriedades dos testes com diferentes matrizes de vizinhança e corrigir o tamanho ao comparar a potência dos testes. Eu obtenho teste invariante ótimo que é também localmente uniformemente mais potente (LUMPI). Construo o envelope de potência para o teste LUMPI e mostro que ele é virtualmente UMP, pois a potência do teste está muito próxima ao envelope (considerando as estruturas espaciais definidas na dissertação). Eu sugiro um procedimento prático para construir um teste que tem boa potência em uma gama de situações onde talvez o teste LUMPI não tenha boas propriedades. Eu concluo que a potência do teste aumenta com o tamanho da amostra e com o parâmetro de dependência espacial (o que está de acordo com a literatura). Entretanto, disputo a visão consensual que a potência do teste diminui a medida que a matriz de vizinhança fica mais densa. Isto reflete um erro de medida comum na literatura, pois a distância estatística entre a hipótese nula e a alternativa varia muito com a estrutura da matriz. Fazendo a correção, concluo que a potência do teste aumenta com a distância da alternativa à nula, como esperado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the quality of weight measurements produced in Primary Health Care Centers in Botucatu and surroundings. 14 Health Care Centers were included, all of them located in four towns in the area of Botucatu (4,555; 5,656; 18,761 and 128,397 inhabitants). General conditions and scale calibration conditions found in those Health Care Centers were evaluated. In order to evaluate the weight accuracy obtained by the local team, 10 adult users of each Center were addressed by the rater during the service routine in order to get a new weight evaluation, immediately after the measurement made by the team. The statistic method applied for checking the weight measurement held in the Heath Care Center and the scales accuracy was the measurement error technique (MET). The results have showed that out of 19 scales, 6 of them overestimated the weight by 50 grams, 1 of them underestimated the weight by 200 grams and the others were accurate. Evaluated as a group, the result of the scale MET was 44.3g. Regarding the conformity of the measures obtained by the MET of the adults weighing in the Health Care Centers compared to the ones obtained by the researcher, the expected result was obtained in only one Center (< 100g). The results have showed data compromise, rather due to lack of health team training than due to the conditions of the equipment used for the measurement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A medida indireta da pressão arterial é um dos procedimentos mais executados pelos enfermeiros de todo o mundo, segundo o Conselho Internacional de Enfermeiras. 0 trabalho discute os principais aspectos polêmicos do instrumental utilizado para a medida indireta da pressão arterial que são causa significativa de erros de medida, a partir da análise da literatura e das recomendações da American Heart Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado, Ensino de História e Geografia no 3.º Ciclo do Ensino Básico e no Ensino Secundário, 10 de Março de 2016, Universidade dos Açores (Relatório de Estágio).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Determinar a confiabilidade das medidas dos diâmetros basal (DBAB) e pós-oclusão (DPOAB) da artéria braquial e da dilatação fluxo-mediada da artéria braquial (DILA), assim como quantificar o erro típico dessas medidas (ETM). MÉTODOS: A consistência interna (2 medidas intradias) foi determinada em 10 voluntários, enquanto a estabilidade (2 medidas interdias) foi determinada em 13 voluntários aparentemente saudáveis e não-fumantes. As imagens da artéria braquial foram obtidas pelo aparelho de ultra-sonografia bidimensional com Doppler, utilizando transdutor de 14 MHz. As distâncias entre as interfaces íntima-luz foram medidas antes e após interrupção do fluxo sangüíneo durante 5 minutos por manguito posicionado no braço. O DILA foi considerado o porcentual de aumento do DPOAB em relação ao DBAB. RESULTADOS: A ANOVA não identificou diferenças significativas entre as medidas intradias e interdias. Para o DILA, os coeficientes de correlação intraclasse entre as medidas intradias e interdias foram R = 0,7001 e R = 0,8420, respectivamente (p < 0,05). Os coeficientes de variação foram 5,8% e 12,4% e os ETM relativos 13,8% e 14,9%, respectivamente para medidas intra e interdias. A análise dos gráficos de Bland-Altman apontou que as variáveis não apresentaram erro heterocedástico. CONCLUSÃO: A medida do DBAB, DPOAB e do DILA por meio de técnica manual pela ultra-sonografia apresenta alta confiabilidade tanto para os valores intradias quanto interdias, possibilitando seu uso para diagnóstico e monitoramento da função endotelial.