998 resultados para Equipment Safety


Relevância:

70.00% 70.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To evaluate the safety of a combined heat and moisture exchanger filter (HMEF) for the conditioning of inspired gas in long-term mechanical ventilation (MV). DESIGN: Randomized controlled trial. SETTING: Medical ICU in a large teaching hospital. PATIENTS: One hundred fifteen consecutive patients who required > or = 48 h of MV. INTERVENTIONS: Patients were randomized at intubation time (day 1) to receive inspired gas conditioned either by a water-bath humidifier heated at 32 degrees C (HWBH) or by an HMEF (Hygroster; DAR; Mirandola, Italy). MEASUREMENTS AND MAIN RESULTS: The two study groups were comparable in terms of primary pathologic condition at the time of hospital admission, disease severity as measured by the Simplified Acute Physiology Score, and ICU mortality. They did not differ with respect to ventilator days per patient (mean +/- SD: HMEF, 7.6 +/- 6.5; HWBH, 7.8 +/- 5.8), incidence of endotracheal tube obstruction (HMEF, 0/59; HWBH, 1/56), and incidence of hypothermic episodes (HMEF, five; HWBH, two). In 41 patients receiving MV for > or = 5 days, the morphologic integrity of respiratory epithelium was evaluated on day 1 and day 5, using a cytologic examination of tracheal aspirate smears. The state of ciliated epithelium was scored on a scale from 0 (poorest integrity) to 1,200 (maximum integrity), according to a well-described method. In both patient groups, the scores slightly but significantly decreased from day 1 to day 5 (mean +/- SD: HWBH, from 787 +/- 104 to 745 +/- 88; HMEF, from 813 +/- 79 to 739 +/- 62; p < 0.01 for both groups); there were no statistically significant differences between groups. CONCLUSIONS: These data indicate acceptable safety of HMEFs of the type used in the present study for long-term mechanical ventilation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Design: Experimental bench study. Setting: The respiratory care laboratory of a university-affiliated teaching hospital. Subject: A computerized mechanical lung model, the IngMar ASL5000. Interventions: Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Measurements and main results: Performance varied widely among ventilators. Mean inspiratory trigger time was < 100 ms for only half of the tested ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Conclusions: Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A intervenção humana no manuseamento de veículos submarinos operados remotamente (ROVs) é um requisito necessário para garantir o sucesso da missão e a integridade do equipamento. Contudo, a sua teleoperação não é fácil, pelo que a condução assistida destes veículos torna-se relevante. Esta dissertação propõe uma solução para este problema para ROVs de 3DOF (surge, heave e yaw). São propostas duas abordagens distintas – numa primeira propõe-se um sistema de controlo Image Based Visual Servoing (IBVS) tendo em vista a utilização exclusiva de uma câmara (sensor existente neste tipo de sistemas) por forma a melhorar significativamente a teleoperação de um pequeno ROV; na segunda, propõe-se um sistema de controlo cinemático para o plano horizontal do veículo e um algoritmo de uma manobra capaz de dotar o ROV de movimento lateral através de uma trajectória dente-de-serra. Demonstrou-se em cenários de operação real que o sistema proposto na primeira abordagem permite ao operador de um ROV com 3DOF executar tarefas de alguma complexidade (estabilização) apenas através de comandos de alto nível, melhorando assim drasticamente a teleoperação e qualidade de inspecção do veículo em questão. Foi também desenvolvido um simulador do ROV em MATLAB para validação e avaliação das manobras, onde o sistema proposto na segunda abordagem foi validado com sucesso.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is well-known that ROVs require human intervention to guarantee the success of their assignment, as well as the equipment safety. However, as its teleoperation is quite complex to perform, there is a need for assisted teleoperation. This study aims to take on this challenge by developing vision-based assisted teleoperation maneuvers, since a standard camera is present in any ROV. The proposed approach is a visual servoing solution, that allows the user to select between several standard image processing methods and is applied to a 3-DOF ROV. The most interesting characteristic of the presented system is the exclusive use of the camera data to improve the teleoperation of an underactuated ROV. It is demonstrated through the comparison and evaluation of standard implementations of different vision methods and the execution of simple maneuvers to acquire experimental results, that the teleoperation of a small ROV can be drastically improved without the need to install additional sensors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Spanish Society of Nursing Emergency (SEEUE) has several lines documentaries that can be consulted on its web page and that have been spread through various publications: Statutes, scientific recommendations, professional recommendations, statements and allegations, grounds for nursing emergency, guarantees and rules, documents of interest and legislation. Set this that composed the regulatory environment, legal and recommendations which society poses to the collective nurse from the area of the emergency, as well as the rest of actors associated with urgent assistance (institutional and administratively) and through what has been the work of conceptualization and definition in our area the past few years. Part of this documentation offer possibilities for scientific endorsement and professional and invites to continue building knowledge and evidence. It is in this sense in which this work can and should be defined from a literature review approach and under the scheme of "review article". The working Group in Primary Care (PC) of the SEEUE, decided to build a Professional Recommendation (PR) in one of the areas of "uncertainty/variability" in the employment context and historical demand of nurses and other emergency care team on security issues: "The uniform and personal protective equipment for professional teams on prehospital emergency areas”.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This manual was developed in cooperation with the Motorcycle Safety Foundation to help you prepare to safely ride a motorcycle. Contains information on motorcycle equipment, safety precautions, laws and earning your license.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O tema do presente estudo consiste na análise da demanda do mercado de taxistas de Curitiba frente à possibilidade de utilização de um combustível alternativo menos oneroso e poluente: o Gás Natural Veicular – GNV. O objetivo principal deste trabalho foi de analisar o mercado atual do GNV entre os taxistas de Curitiba, verificando a possibilidade de ampliar do uso do GNV por esta frota através de uma pesquisa de mercado. Os dados da pesquisa servirão de subsídios para campanhas de marketing orientadas à ampliação acelerada do uso desta tecnologia. Para tanto, realizou-se uma pesquisa de satisfação para levantar os fatores determinantes para a tomada de decisão dos taxistas de Curitiba de utilizarem ou não um combustível alternativo menos oneroso e poluente como o Gás Natural Veicular – GNV. O estudo visou obter a percepção dos taxistas de Curitiba. Com base nos resultados da pesquisa foi possível estabelecer subsídios para campanhas de marketing orientadas à ampliação acelerada do uso desta tecnologia. Para realização da pesquisa, utilizou-se uma pesquisa exploratória, com entrevistas individuais da cúpula das organizações que trabalham com o Gás Natural, prospectando novos projetos para o futuro e as perspectivas de evolução do mercado de GNV em Curitiba, a qual forneceu subsídios para a pesquisa quantitativa junto aos taxistas da cidade de Curitiba. Constatou-se que somente 36% do público estudado é usuário de gás natural veicular, mas entre os não usuários, 82% já pensou em instalar o kit gás. As principais razões pelas quais os taxistas pesquisados não utilizam o GNV são a perda de espaço no porta-malas e a perda de potência do veículo. Entre os taxistas que utilizam o GNV, no que tange aos atributos relacionados à rede de distribuição, a maior insatisfação refere-se à localização dos postos e a maior satisfação às eventuais filas para abastecimento. Nesses mesmos atributos o que obteve maior índice de importância foi justamente a localização dos postos. Entre os atributos relacionados ao produto, o maior índice de satisfação foi o nível de poluição ambiental e a maior insatisfação espaço para armazenamento, sendo o desempenho do veículo considerado o mais importante. Quanto aos atributos relacionados aos equipamentos, verificou-se a segurança com o maior índice de satisfação e de importância.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Title from cover.