978 resultados para Equipment, Warming Mattress


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peroperative hypothermia is recognized to increase mortality and morbidity, and the paediatric anaesthetist faces specific challenges resulting from the increased body surface to volume ratio, particularly in smaller children. We describe three children who were consecutive patients on one operating list and sustained severe thermal injuries. These were due to a malfunctioning electrical heating mat, despite appropriate use and monitoring by the attending anaesthetist. It is rare for thermal warming devices to cause injury. We review the use of heating mats, and suggest modifications in their manufacture which may minimize the risks associated with heating devices.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: Mild therapeutic hypothermia has been shown to improve outcome for patients after cardiac arrest and may be beneficial for ischaemic stroke and myocardial ischaemia patients. However, in the awake patient, even a small decrease of core temperature provokes vigorous autonomic reactions-vasoconstriction and shivering-which both inhibit efficient core cooling. Meperidine and skin warming each linearly lower vasoconstriction and shivering thresholds. We tested whether a combination of skin warming and a medium dose of meperidine additively would reduce the shivering threshold to below 34 degrees C without producing significant sedation or respiratory depression. METHODS: Eight healthy volunteers participated on four study days: (1) control, (2) skin warming (with forced air and warming mattress), (3) meperidine (target plasma level: 0.9 mug/ml), and (4) skin warming plus meperidine (target plasma level: 0.9 mug/ml). Volunteers were cooled with 4 degrees C cold Ringer lactate infused over a central venous catheter (rate asymptotically equal to 2.4 degrees C/hour core temperature drop). Shivering threshold was identified by an increase of oxygen consumption (+20% of baseline). Sedation was assessed with the Observer's Assessment of Alertness/Sedation scale. RESULTS: Control shivering threshold was 35.5 degrees C +/- 0.2 degrees C. Skin warming reduced the shivering threshold to 34.9 degrees C +/- 0.5 degrees C (p = 0.01). Meperidine reduced the shivering threshold to 34.2 degrees C +/- 0.3 degrees C (p < 0.01). The combination of meperidine and skin warming reduced the shivering threshold to 33.8 degrees C +/- 0.2 degrees C (p < 0.01). There were no synergistic or antagonistic effects of meperidine and skin warming (p = 0.59). Only very mild sedation occurred on meperidine days. CONCLUSION: A combination of meperidine and skin surface warming reduced the shivering threshold to 33.8 degrees C +/- 0.2 degrees C via an additive interaction and produced only very mild sedation and no respiratory toxicity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Actively warming patients during surgery is considered the best method of preventing inadvertent hypothermia due to multiple causes: anaesthetic depression of the hypothalamic thermoregulatory centre, cutaneous vasodilatation, reduction of heat production by skeletal muscles, cold intravenous fluid administration and heat loss from opened body cavities. To compare the effects of active peripheral skin warming and trunk warming on body temperature during surgery, 15 dogs undergoing ovariohysterectomy were studied using a prospective randomised trial design. Dogs were randomised into two groups: one group was warmed by compress leg pads (n=7) on limbs and the other group by a circulating warm water mattress (n=8), applied to the trunk. The rectal, oesophageal and room temperatures and relative humidity were measured. The results showed that the compress leg pads (active peripheral warming) were significantly (P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims and objectives. To examine the impact of written and verbal education on bed-making practices, in an attempt to reduce the prevalence of pressure ulcers. Background. The Department of Health has set targets for a 5% reduction per annum in the incidence of pressure ulcers. Electric profiling beds with a visco-elastic polymer mattress are a new innovation in pressure ulcer prevention; however, mattress efficacy is reduced by tightly tucking sheets around the mattress. Design. A prospective randomized pre/post-test experimental design. Methods. Ward managers at a teaching hospital were approached to participate in the study. Two researchers independently examined the tightness of the sheets around the mattresses. Wards were randomized to one of two groups. Groups A and B received written education. In addition, group B received verbal education on alternate days for one week. Beds were re-examined one month later. One researcher was blinded to the educational delivery received by the wards. Results. Twelve wards agreed to participate in the study and 245 beds were examined. Before education, 113 beds (46%) had sheets tucked correctly around the mattresses. Following education, this increased to 215 beds (87.8%) (chi(2) = 68.03, P < 0.001). There was no significant difference in the number of correctly made beds between the two different education groups: 100 (87.72%) beds correctly made in group A vs. 115 (87.79%) beds in group B (chi(2) = 0, P 0.987). Conclusions. Clear, concise written instruction improved practice but verbal education was not additionally beneficial. Relevance to clinical practice. Nurses are receptive to clear, concise written evidence regarding pressure ulcer prevention and incorporate this into clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: Hipotermia inadvertida no perioperatório é freqüente durante anestesia subaracnóidea e após a administração de midazolam. O objetivo foi avaliar os efeitos do aquecimento da pele no intra-operatório, associado ou não ao aquecimento da pele durante o período de 45 minutos no pré-operatório, na prevenção de hipotermia intra- e pós-operatória determinada pela anestesia subaracnóidea em pacientes com medicação pré-anestésica com midazolam. TIPO DE ETUDO E LOCAL: Estudo prospectivo e aleatório, realizado no Hospital das Clínicas, Universidade Estadual Paulista (Unesp), Botucatu, SP. MÉTODOS: O estudo foi realizado em 30 pacientes com estado físico ASA (da Sociedade Norte-americana de Anestesiologistas) I e II submetidos à cirurgia eletiva do abdômen. Como medicação pré-anestésica, utilizou-se o midazolam, 7,5 mg via intramuscular (IM) e anestesia subaracnóidea padrão. em 10 pacientes (Gcontrole) utilizou-se isolamento térmico passivo; 10 pacientes (Gpré+intra) foram submetidos a aquecimento ativo no pré- e intra-operatório; e 10 pacientes (Gintra) foram aquecidos ativamente somente no intra-operatório. RESULTADOS: Após 45 minutos de aquecimento no pré-operatório, os pacientes do Gpré+intra apresentaram temperatura central mais elevada em relação aos dos grupos não aquecidos antes da anestesia (p < 0,05) mas não no início da cirurgia (p > 0,05). Os pacientes que receberam aquecimento no intra-operatório apresentaram temperatura central mais elevada no final da cirurgia em relação aos de Gcontrole (p < 0,05). Todos os pacientes estavam hipotérmicos na admissão da sala de recuperação pós-anestésica (temperatura central < 36º C). CONCLUSÕES: 45 minutos de aquecimento no pré-operatório combinado com aquecimento no intra- operatório não evita, mas minimiza a ocorrência de hipotermia determinada pela anestesia subaracnóidea em pacientes que receberam midazolam como medicação pré-anestésica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Mild perioperative hypothermia increases the risk of several severe complications. Perioperative patient warming to preserve normothermia has thus become routine, with forced-air warming being used most often. In previous studies, various resistive warming systems have shown mixed results in comparison with forced-air. Recently, a polymer-based resistive patient warming system has been developed. We compared the efficacy of a standard forced-air warming system with the resistive polymer system in volunteers. METHODS: Eight healthy volunteers participated, each on two separate study days. Unanesthetized volunteers were cooled to a core temperature (tympanic membrane) of 34 degrees C by application of forced-air at 10 degrees C and a circulating-water mattress at 4 degrees C. Meperidine and buspirone were administered to prevent shivering. In a randomly designated order, volunteers were then rewarmed (until their core temperatures reached 36 degrees C) with one of the following active warming systems: (1) forced-air warming (Bair Hugger warming cover #300, blower #750, Arizant, Eden Prairie, MN); or (2) polymer fiber resistive warming (HotDog whole body blanket, HotDog standard controller, Augustine Biomedical, Eden Prairie, MN). The alternate system was used on the second study day. Metabolic heat production, cutaneous heat loss, and core temperature were measured. RESULTS: Metabolic heat production and cutaneous heat loss were similar with each system. After a 30-min delay, core temperature increased nearly linearly by 0.98 (95% confidence interval 0.91-1.04) degrees C/h with forced-air and by 0.92 (0.85-1.00) degrees C/h with resistive heating (P = 0.4). CONCLUSIONS: Heating efficacy and core rewarming rates were similar with full-body forced-air and full-body resistive polymer heating in healthy volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Hipotermia intra-operatória é complicação frequente, favorecida por operação abdominal. A eficácia da associação dos métodos de aquecimento por condução e convecção na prevenção de hipotermia e seus efeitos no período de recuperação pós-operatória foram os objetivos deste estudo. MÉTODO: Quarenta e três pacientes de ambos os sexos de 18 a 88 anos de idade, submetidos à laparotomia xifopúbica sob anestesia geral e monitorização da temperatura esofágica, foram distribuídos de modo aleatório em dois grupos de aquecimento: COND (n = 24), com colchão de circulação de água a 37°C no dorso e COND + CONV (n = 19), com a mesma condição associada à manta de ar aquecido a 42°C sobre o tórax e membros superiores. Analisados peso, sexo, idade, duração da operação e anestesia, temperaturas na indução anestésica (Mi), horas consecutiva (M1, M2), final da operação (Mfo) e anestesia (Mfa), entrada (Me-REC) e saída (Ms-REC) da recuperação pós-anestésica (SRPA), além das incidências de tremores e queixas de frio no pós-operatório. RESULTADOS: Os grupos foram semelhantes em todas as variáveis analisadas, exceto nas temperaturas em M2, M3, M4, Mfo e Mfa. O grupo COND reduziu a temperatura a partir da segunda hora da indução anestésica, mas o grupo COND + CONV só na quarta hora. Em COND, observou-se hipotermia na entrada e saída da SRPA. CONCLUSÕES: Associar métodos de aquecimento retardou a instalação e diminui a intensidade da hipotermia intra-operatória, mas não reduziu a incidência das queixas de frio e tremores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents a decision-making method for maintenance policy selection of power plants equipment. The method is based on risk analysis concepts. The method first step consists in identifying critical equipment both for power plant operational performance and availability based on risk concepts. The second step involves the proposal of a potential maintenance policy that could be applied to critical equipment in order to increase its availability. The costs associated with each potential maintenance policy must be estimated, including the maintenance costs and the cost of failure that measures the critical equipment failure consequences for the power plant operation. Once the failure probabilities and the costs of failures are estimated, a decision-making procedure is applied to select the best maintenance policy. The decision criterion is to minimize the equipment cost of failure, considering the costs and likelihood of occurrence of failure scenarios. The method is applied to the analysis of a lubrication oil system used in gas turbines journal bearings. The turbine has more than 150 MW nominal output, installed in an open cycle thermoelectric power plant. A design modification with the installation of a redundant oil pump is proposed for lubricating oil system availability improvement. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development and Characterization of L-Alanyl-L-Glutamine Containing Pellets employing Extrusion-Spheronization Method and Drying Process in Fluidized Bad Equipment"". In this work, five formulations of L-alanyl-L-glutamine (glutamine dipeptide) containing pellets with different drug concentration were developed and evaluated: F1 (9.07%); F2 (17.70%); F3 (27.98%); F4 (37.74%) e F5 (47.53%). Pellets were prepared by extrusion-spheronization method and, further, dried in fluidized bad equipment. The following assays were carried out with the batches obtained: granulometry, friability, true density and morphologic analysis. Between the five formulations evaluated, pellets obtained from F3 present best yield (75.80%), most uniform particle size distribution (89.67% of pellets with size in the range of 0.80 to 1.18), most high true density (2.1634 g/ml) and best aspect (1.0795 +/- 0.0410). Due to these features, pellets obtained from F3 were considered adequate to further polymeric coating process in order to produce a multiparticulate system to prolong L-alanyl-L-glutamine release.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of a basic (i.e., essential) medical emergency kit suitable for a general dental practitioner varies somewhat between different authorities. A practitioner's choice is also dependant on the proximity of medical aid and the nature of the dental practice. Over recent years the trend has been to restrict the items to a minimum, in the interest of both common sense and safety, for example, just oxygen, adrenaline 1:1000, an oral carbohydrate source, glyceryl trinitrate and aspirin as first options. Ancillary equipment should include an oxygen therapy facemask, a pocket mask and a set of oral (Guedel) airways. Two further medication options for consideration are an aerosol bronchodilator and, in certain circumstances, an injectable antihypoglycaemic agent. This paper provides a selective overview of the subject. An absolute necessity is for dentists to be competent in Basic Life Support skills, and to maintain a complete and current medical history for all patients.