995 resultados para Electric parameters


Relevância:

100.00% 100.00%

Publicador:

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En termes generals, es pot definir l’Eficiència Energètica com la reducció del consum d’energia mantenint els mateixos serveis energètics, sense disminuir el nostre confort i qualitat de vida, protegint el medi ambient, assegurant el proveïment i fomentant un comportament Sostenible al seu ús. L’objectiu principal d’aquest treball, és reduir el consum d’energia i terme de potència contractat a la Universitat de Vic, aplicant un programa d’estalvi amb mesures correctores en el funcionament de les seves instal·lacions o espais. Per tal de poder arribar a aquest objectiu marcat, prèviament s’ha realitzat un estudi acurat, obtenint tota la informació necessària per poder aplicar les mesures correctores a la bossa més important de consum. Un cop trobada, dur a terme l’estudi de la viabilitat de la inversió de les mesures correctores més eficients, optimitzant els recursos destinats. L’espai on s’ha dut a terme l’estudi, ha estat a l’edifici F del Campus Miramarges, seguint les indicacions d’Arnau Bardolet (Cap de Manteniment de la UVIC). Aquest edifici consta d’un entresol, baixos i quatre plantes. L’equip de mesura que s’ha fet servir per realitzar l’estudi, és de la marca Circutor sèrie AR5-L, aquests equips són programables que mesuren, calculen i emmagatzemen en memòria els principals paràmetres elèctrics en xarxes trifàsiques. Els projectes futurs complementaris que es podrien realitzar a part d’aquest són: instal·lar sensors, instal·lar mòduls convertidors TCP/IP, aprofitar la xarxa intranet i crear un escada amb un sinòptic de control i gestió des d’un punt de treball. Aquest aplicatiu permet visualitzar en una pantalla d’un PC tots els estats dels elements controlats mitjançant un sinòptic (encendre/parar manualment l’enllumenat i endolls de les aules, estat d’enllumenat i endolls de les aules, consums instantanis/acumulats energètics, estat dels passadissos entre altres) i explotar les dades recollides a la base de dades. Cada espai tindria la seva lògica de funcionament automàtic específic. Entre les conclusions més rellevants obtingudes en aquest treball s’observa: · Que és pot reduir la potència contractada a la factura a l’estar per sota de la realment consumida. · Que no hi ha penalitzacions a la factura per consum de reactiva, ja que el compensador funciona correctament. · Que es pot reduir l’horari de l’inici del consum d’energia, ja que no correspon a l’activitat docent. · Els valors de la tensió i freqüència estan dintre de la normalitat. · Els harmònics estan al llindar màxim. Analitzant aquestes conclusions, voldria destacar les mesures correctores més importants que es poden dur a terme: canvi tecnològic a LED, temporitzar automàticament l’encesa i apagada dels fluorescents i equips informàtics de les aules “seguint calendari docent”, instal·lar sensors de moviment amb detecció lumínica als passadissos. Totes les conclusions extretes d’aquest treball, es poden aplicar a tots els edificis de la facultat, prèviament realitzant l’estudi individual de cadascuna, seguint els mateixos criteris per tal d’optimitzar la inversió.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En termes generals, es pot definir l’Eficiència Energètica com la reducció del consum d’energia mantenint els mateixos serveis energètics, sense disminuir el nostre confort i qualitat de vida, protegint el medi ambient, assegurant el proveïment i fomentant un comportament Sostenible al seu ús. L’objectiu principal d’aquest treball, és reduir el consum d’energia i terme de potència contractat a la Universitat de Vic, aplicant un programa d’estalvi amb mesures correctores en el funcionament de les seves instal·lacions o espais. Per tal de poder arribar a aquest objectiu marcat, prèviament s’ha realitzat un estudi acurat, obtenint tota la informació necessària per poder aplicar les mesures correctores a la bossa més important de consum. Un cop trobada, dur a terme l’estudi de la viabilitat de la inversió de les mesures correctores més eficients, optimitzant els recursos destinats. L’espai on s’ha dut a terme l’estudi, ha estat a l’edifici F del Campus Miramarges, seguint les indicacions d’Arnau Bardolet (Cap de Manteniment de la UVIC). Aquest edifici consta d’un entresol, baixos i quatre plantes. L’equip de mesura que s’ha fet servir per realitzar l’estudi, és de la marca Circutor sèrie AR5-L, aquests equips són programables que mesuren, calculen i emmagatzemen en memòria els principals paràmetres elèctrics en xarxes trifàsiques. Els projectes futurs complementaris que es podrien realitzar a part d’aquest són: instal·lar sensors, instal·lar mòduls convertidors TCP/IP, aprofitar la xarxa intranet i crear un escada amb un sinòptic de control i gestió des d’un punt de treball. Aquest aplicatiu permet visualitzar en una pantalla d’un PC tots els estats dels elements controlats mitjançant un sinòptic (encendre/parar manualment l’enllumenat i endolls de les aules, estat d’enllumenat i endolls de les aules, consums instantanis/acumulats energètics, estat dels passadissos entre altres) i explotar les dades recollides a la base de dades. Cada espai tindria la seva lògica de funcionament automàtic específic. Entre les conclusions més rellevants obtingudes en aquest treball s’observa: · Que és pot reduir la potència contractada a la factura a l’estar per sota de la realment consumida. · Que no hi ha penalitzacions a la factura per consum de reactiva, ja que el compensador funciona correctament. · Que es pot reduir l’horari de l’inici del consum d’energia, ja que no correspon a l’activitat docent. · Els valors de la tensió i freqüència estan dintre de la normalitat. · Els harmònics estan al llindar màxim. Analitzant aquestes conclusions, voldria destacar les mesures correctores més importants que es poden dur a terme: canvi tecnològic a LED, temporitzar automàticament l’encesa i apagada dels fluorescents i equips informàtics de les aules “seguint calendari docent”, instal·lar sensors de moviment amb detecció lumínica als passadissos. Totes les conclusions extretes d’aquest treball, es poden aplicar a tots els edificis de la facultat, prèviament realitzant l’estudi individual de cadascuna, seguint els mateixos criteris per tal d’optimitzar la inversió.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article analyzes the electrical parameters of a 3-phase transmission line using a 280-m-high steel tower that has been proposed for the Amazon transmission system in Brazil. The height of the line conductors and the distance between them are intrinsically related to the longitudinal and transverse parameters of the line. Hence, an accurate study is carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 3-phase 440-kV line, considering a wide range of frequencies and variable soil resistivity. First, a brief review of the fundamental theory of line parameters is presented. In addition, by using a digital line model, simulations are carried out in the time domain to analyze possible and critical over-voltage transients on the proposed line representation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes an alternative procedure to obtain an equivalent conductor from a bundled conductor, taking into account the distribution of the current in subcondutors of the bundle. Firstly, it is introduced a brief background about the concept of Geometric Mean Radius (GMR) and how this methodology is applied to define an equivalent conductor and its electric parameters. Emphasizing that the classical procedure, using GMR, is limited to premise which the current is equally distributed through subconductors. Afterwards, it is described the development of proposed method and applications for an equivalent conductor obtained from a conventional transmission line bundled conductor and from an equivalent conductor based on a bundle with compressed SF(6) insulation system, where the current is unequally distributed through subconductors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electric and dielectric properties of the grain boundary of Na0.85Li0.15NbO3 lead-free ferroelectric-semiconductor perovskite were investigated. The impedance spectroscopy was carried out as a function of a thermal cycle. The sodium lithium niobate was synthesized by a chemical route based on the evaporation method. Dense ceramic, relative density of 97%, was prepared at 1423 K for 2 h in air atmosphere. ac measurements were carried out in the frequency range of 5 Hz-13 MHz and from 673 to 1023 K. Theoretical adjust of the impedance data was performed to deriving the electric parameters of the grain boundary. The electric conductivity follows the Arrhenius law, with activation energy values equal to 1.55 and 1.54 eV for heating and cooling cycle, respectively. The nonferroelectric state of the grain boundary and its correlation with symmetry are discussed in the temperature domain. (C) 2003 American Institute of Physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper represents the results of the work carried out in order to study the condition of seasonal consumer, the load factor and the more convenient tariff for a sugar mill located in the Vale do Paranapanema, SP, Brazil. Therefore, data of consume and registered demand were collected during the quadriennium 1990 to 1994. The studies showed that the factory did not maintain the condition of seasonal consumer of electric energy during the analysed period. Low values of the load factor observed in the period showed a non rational use of electric energy supplied by the concessionary. The results showed that only in one situation (load retired in top equal to 90%) the most convenient tariff is the horo-sazonal azul. In the other situations the most convenient tariff is the conventional one.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Polymer aluminum electrolytic capacitors were introduced to provide an alternative to liquid electrolytic capacitors. Polymer electrolytic capacitor electric parameters of capacitance and ESR are less temperature dependent than those of liquid aluminum electrolytic capacitors. Furthermore, the electrical conductivity of the polymer used in these capacitors (poly-3,4ethylenedioxithiophene) is orders of magnitude higher than the electrolytes used in liquid aluminum electrolytic capacitors, resulting in capacitors with much lower equivalent series resistance which are suitable for use in high ripple-current applications. The presence of the moisture-sensitive polymer PEDOT introduces concerns on the reliability of polymer aluminum capacitors in high humidity conditions. Highly accelerated stress testing (or HAST) (110ºC, 85% relative humidity) of polymer aluminum capacitors in which the parts were subjected to unbiased HAST conditions for 700 hours was done to understand the design factors that contribute to the susceptibility to degradation of a polymer aluminum electrolytic capacitor exposed to HAST conditions. A large scale study involving capacitors of different electrical ratings (2.5V – 16V, 100µF – 470 µF), mounting types (surface-mount and through-hole) and manufacturers (6 different manufacturers) was done to determine a relationship between package geometry and reliability in high temperature-humidity conditions. A Geometry-Based HAST test in which the part selection limited variations between capacitor samples to geometric differences only was done to analyze the effect of package geometry on humidity-driven degradation more closely. Raman spectroscopy, x-ray imaging, environmental scanning electron microscopy, and destructive analysis of the capacitors after HAST exposure was done to determine the failure mechanisms of polymer aluminum capacitors under high temperature-humidity conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electron transport parameters are important in several areas ranging from particle detectors to plasma-assisted processing reactors. Nevertheless, especially at high fields strengths and for complex gases, relatively few data are published. A dedicated setup has been developed to measure the electron drift velocity and the first Townsend coefficient in parallel plate geometry. An RPC-like cell has been adopted to reach high field strengths without the risk of destructive sparks. The validation data obtained with pure Nitrogen will be presented and compared to a selection of the available literature and to calculations performed with Magboltz 2 version 8.6. The new data collected in pure Isobutane will then be discussed. This is the first time the electron drift velocity in pure Isobutane is measured well into the saturation region. Good agreement is found with expectations from Magboltz. (C) 2009 Elsevier B.V. All rights reserved.