919 resultados para Digital transmission equipment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work design criteria for cooling of electronic systems used in a digital transmission equipment are considered. An experimental study using a simulated electronic equipment in which vertically oriented circuit boards are aligned to form vertical channels is carried out. Resistors are used to simulate actual components. The temperature of several components in the printed circuit boards are measured and the influence of the baffles and shields on the cooling effect are discussed. It was observed that the use of the baffles reduce the temperature levels and, the use of shields, although protecting the components from magnetic effects, cause an increase in the temperature levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modern society has come to expect the electrical energy on demand, while many of the facilities in power systems are aging beyond repair and maintenance. The risk of failure is increasing with the aging equipments and can pose serious consequences for continuity of electricity supply. As the equipments used in high voltage power networks are very expensive, economically it may not be feasible to purchase and store spares in a warehouse for extended periods of time. On the other hand, there is normally a significant time before receiving equipment once it is ordered. This situation has created a considerable interest in the evaluation and application of probability methods for aging plant and provisions of spares in bulk supply networks, and can be of particular importance for substations. Quantitative adequacy assessment of substation and sub-transmission power systems is generally done using a contingency enumeration approach which includes the evaluation of contingencies, classification of the contingencies based on selected failure criteria. The problem is very complex because of the need to include detailed modelling and operation of substation and sub-transmission equipment using network flow evaluation and to consider multiple levels of component failures. In this thesis a new model associated with aging equipment is developed to combine the standard tools of random failures, as well as specific model for aging failures. This technique is applied in this thesis to include and examine the impact of aging equipments on system reliability of bulk supply loads and consumers in distribution network for defined range of planning years. The power system risk indices depend on many factors such as the actual physical network configuration and operation, aging conditions of the equipment, and the relevant constraints. The impact and importance of equipment reliability on power system risk indices in a network with aging facilities contains valuable information for utilities to better understand network performance and the weak links in the system. In this thesis, algorithms are developed to measure the contribution of individual equipment to the power system risk indices, as part of the novel risk analysis tool. A new cost worth approach was developed in this thesis that can make an early decision in planning for replacement activities concerning non-repairable aging components, in order to maintain a system reliability performance which economically is acceptable. The concepts, techniques and procedures developed in this thesis are illustrated numerically using published test systems. It is believed that the methods and approaches presented, substantially improve the accuracy of risk predictions by explicit consideration of the effect of equipment entering a period of increased risk of a non-repairable failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brazil is going through the process from analogical transmission to digital transmission. This new technology, in addition to providing a high quality audio and video, also allows applications to execute on television. Equipment called Set-Top Box are needed to allow the reception of this new signal and create the appropriate environment necessary to execute applications. At first, the only way to interact with these applications is given by remote control. However, the remote control has serious usability problems when used to interact with some types of applications. This research suggests a software resources implementation capable to create a environment that allows a smartphone to interact with applications. Besides this implementation, is performed a comparative study between use remote controle and smartphones to interact with applications of digital television, taking into account parameters related to usability. After analysis of data collected by the comparative study is possible to identify which device provides an interactive experience more interesting for users

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Accompanied by "Appendix--comment letters, docket RM 90-6" (ix, 615 p. ; 28 cm.).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes the design and implementation of a wireless neural telemetry system that enables new experimental paradigms, such as neural recordings during rodent navigation in large outdoor environments. RoSco, short for Rodent Scope, is a small lightweight user-configurable module suitable for digital wireless recording from freely behaving small animals. Due to the digital transmission technology, RoSco has advantages over most other wireless modules of noise immunity and online user-configurable settings. RoSco digitally transmits entire neural waveforms for 14 of 16 channels at 20 kHz with 8-bit encoding which are streamed to the PC as standard USB audio packets. Up to 31 RoSco wireless modules can coexist in the same environment on non-overlapping independent channels. The design has spatial diversity reception via two antennas, which makes wireless communication resilient to fading and obstacles. In comparison with most existing wireless systems, this system has online user-selectable independent gain control of each channel in 8 factors from 500 to 32,000 times, two selectable ground references from a subset of channels, selectable channel grounding to disable noisy electrodes, and selectable bandwidth suitable for action potentials (300 Hz–3 kHz) and low frequency field potentials (4 Hz–3 kHz). Indoor and outdoor recordings taken from freely behaving rodents are shown to be comparable to a commercial wired system in sorting for neural populations. The module has low input referred noise, battery life of 1.5 hours and transmission losses of 0.1% up to a range of 10 m.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to develop and test new digital imaging equipment and methods for diagnosis and follow-up of ocular diseases. Methods: The whole material comprised 398 subjects (469 examined eyes), including 241 patients with melanocytic choroidal tumours, 56 patients with melanocytic iris tumours, 42 patients with diabetes, a 52-year old patient with chronic phase of VKH disease, a 30-year old patient with an old blunt eye injury, and 57 normal healthy subjects. Digital 50° (Topcon TRC 50 IA) and 45° (Canon CR6-45NM) fundus cameras, a new handheld digital colour videocamera for eye examinations (MediTell), a new subtraction method using the Topcon Image Net Program (Topcon corporation, Tokyo, Japan), a new method for digital IRT imaging of the iris we developed, and Zeiss photoslitlamp with a digital camera body were used for digital imaging. Results: Digital 50° red-free imaging had a sensitivity of 97.7% and two-field 45° and 50° colour imaging a sensitivity of 88.9-94%. The specificity of the digital 45°-50° imaging modalities was 98.9-100% versus the reference standard and ungradeable images that were 1.2-1.6%. By using the handheld digital colour video camera only, the optic disc and central fundus located inside 20° from the fovea could be recorded with a sensitivity of 6.9% for detection of at least mild NPDR when compared with the reference standard. Comparative use of digital colour, red-free, and red light imaging showed 85.7% sensitivity, 99% specificity, and 98.2 % exact agreement versus the reference standard in differentiation of small choroidal melanoma from pseudomelanoma. The new subtraction method showed growth in four of 94 melanocytic tumours (4.3%) during a mean ±SD follow-up of 23 ± 11 months. The new digital IRT imaging of the iris showed the sphincter muscle and radial contraction folds of Schwalbe in the pupillary zone and radial structural folds of Schwalbe and circular contraction furrows in the ciliary zone of the iris. The 52-year-old patient with a chronic phase of VKH disease showed extensive atrophy and occasional pigment clumps in the iris stroma, detachment of the ciliary body with severe ocular hypotony, and shallow retinal detachment of the posterior pole in both eyes. Infrared transillumination imaging and fluorescein angiographic findings of the iris showed that IR translucence (p=0.53), complete masking of fluorescence (p=0.69), presence of disorganized vessels (p=0.32), and fluorescein leakage (p=1.0) at the site of the lesion did not differentiate an iris nevus from a melanoma. Conclusions: Digital 50° red-free and two-field 50° or 45° colour imaging were suitable for DR screening, whereas the handheld digital video camera did not fulfill the needs of DR screening. Comparative use of digital colour, red-free and red light imaging was a suitable method in the differentiation of small choroidal melanoma from different pseudomelanomas. The subtraction method may reveal early growth of the melanocytic choroidal tumours. Digital IRT imaging may be used to study changes of the stroma and posterior surface of the iris in various diseases of the uvea. It contributed to the revealment of iris atrophy and serous detachment of the ciliary body with ocular hypotony together with the shallow retinal detachment of the posterior pole as new findings of the chronic phase of VKH disease. Infrared translucence and angiographic findings are useful in differential diagnosis of melanocytic iris tumours, but they cannot be used to determine if the lesion is benign or malignant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel digital image correlation (DIC) technique has been developed to track changes in textile yarn orientations during shear characterisation experiments, requiring only low-cost digital imaging equipment. Fabric shear angles and effective yarn strains are calculated and visualised using this new DIC technique for bias extension testing of an aerospace grade, carbon-fibre reinforcement material with a plain weave architecture. The DIC results are validated by direct measurement, and the use of a wide bias extension sample is evaluated against a more commonly used narrow sample. Wide samples exhibit a shear angle range 25% greater than narrow samples and peak loads which are 10 times higher. This is primarily due to excessive yarn slippage in the narrow samples; hence, the wide sample configuration is recommended for characterisation of shear properties which are required for accurate modelling of textile draping.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Digital technology has promoted a great popularization of photographic registration in several medical areas. Because of its visual nature, dermatology has incorporated the benefits of this tool in clinical practice and research. This article aims to offer guidance to the dermatologist who is unfamiliar with this technology, providing basic understanding for the best use of digital photography equipment. ©2006 by Anais Brasileiros de Dermatologia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O trabalho aborda questões sobre a produção e composição da imagem em alta definição na TV Digital HDTV. Por meio dos dados levantados na literatura específica, impressa e eletrônica, e com entrevistas com profissionais da área e observações da programação disponível em HDTV na cidade de São Paulo puderam ser analisadas as imagens e composição visual que advém com a TV Digital de alta definição e interativa. Para tanto, a produção da imagem em alta definição precisa atender a dois tipos de público: o que assiste a transmissão digital e o que ainda continuará assistindo no sistema analógico com baixa percepção para os detalhes visuais. Os resultados demonstraram duas questões fundamentais e interdependentes: as práticas de produção, materiais cenográficos e processos de composição dos elementos da imagem precisam ser atualizados segundo as novas características tecnológicas e que o processo de implantação da TV Digital no Brasil deve ser revisto, com correções de prazos e das políticas adotadas sob o risco de se atrasar todo o processo de produção de conteúdo e da imagem em alta definição para este suporte.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis presents improvements to optical transmission systems through the use of optical solitons as a digital transmission format, both theoretically and experimentally. An introduction to the main concepts and impairments of optical fibre on pulse transmission is included before introducing the concept of solitons in optically amplified communications and the problems of soliton system design. The theoretical work studies two fibre dispersion profiling schemes and a soliton launch improvement. The first provides superior pulse transmission by optimally tailoring the fibre dispersion to better follow the power, and hence nonlinearity, decay and thus allow soliton transmission for longer amplifier spacings and shorter pulse widths than normally possible. The second profiling scheme examines the use of dispersion compensating fibre in the context of soliton transmission over existing, standard fibre systems. The limits for solitons in uncompensated standard fibre are assessed, before the potential benefits of dispersion compensating fibre included as part of each amplifier are shown. The third theoretical investigation provides a simple improvement to the propagation of solitons in a highly perturbed system. By introducing a section of fibre of the correct length prior to the first system amplifier span, the soliton shape can be better coupled into the system thus providing an improved "average soliton" propagation model. The experimental work covers two areas. An important issue for soliton systems is pulse sources. Three potential lasers are studied, two ring laser configurations and one semiconductor device with external pulse shaping. The second area studies soliton transmission using a recalculating loop, reviewing the advantages and draw-backs of such an experiment in system testing and design. One particular example of employing the recirculating loop is also examined, using a novel method of pulse shape stabilisation over long distances with low jitter. The future for nonlinear optical communications is considered with the thesis conclusions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

SR型人工降雨装置是一种多喷头、多单元组合式的间歇降雨装置。选用目前国内外较理想的喷头 ,在喷头处辅以可改变喷头降水方式的机械传动装置 ,以间歇方式降雨来满足其降雨强度 ,雨滴直径大小及其分布与自然降雨相似。每个单元的有效降雨面积为 2 m× 5 m;如果 4个单元组合成 ,其长度可增加 4倍 ,有效降雨面积即 2 m× 2 0 m。装置采用轻型铝合金材料制成 ,结构简单 ,易于安装拆卸 ,适用于野外工作。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Os equipamentos de medição utilizados nos hospitais têm uma função muito importante na deteção e diagnóstico de doenças como é o caso da pressão arterial. Entre esses equipamentos encontram-se os esfigmomanómetros digitais portáteis que são em muitos casos os primeiros a serem utilizados e a fornecerem um primeiro diagnóstico da pressão arterial do doente como é no caso das urgências hospitalares. Para que os diagnósticos prescritos pelos profissionais de saúde - médicos e enfermeiros seja o mais correto é necessário conhecer as condições de trabalho em que se encontram os esfigmomanómetros digitais existentes nas unidades de saúde. Sendo os esfigmomanómetros digitais equipamentos com uma importância relevante na vida do ser humano, estes deveriam fazer parte da lista de equipamentos que estão englobados na metrologia legal, situação que neste momento ainda não foi concretizada e cada hospital toma a decisão espontânea se efetua a calibração ou verificação internamente dos seus esfigmomanómetros digitais. Pretende-se com este trabalho dar a conhecer o estado ao nível dos erros de alguns esfigmomanómetros digitais existentes nos hospitais envolvidos no trabalho e desenvolver um procedimento de verificação interna dos mesmos com auxílio de um manómetro analógico calibrado e um estetoscópio duplo – método de medição auscultatório - e comparar esses resultados com a utilização de um simulador – método de medição oscilométrico.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"Thèse présentée à la Faculté des études supérieures en vue de l'obtention du grade de docteur en droit"