1000 resultados para Differential-mode
Resumo:
In this paper, we investigate the design of few-mode fibers (FMFs) guiding 4 to 12 non-degenerate linearly polarized (LP) modes with low differential mode delay (DMD) over the C-band, suitable for long-haul transmission. The refractive index profile considered is composed by a graded-core with a cladding trench (GCCT). The optimization of the profile parameters aims the lowest possible DMD and macro-bend losses (MBL) lower than the ITU-T standard recommendation. The optimization results show that the optimum DMD and the MBL scale with the number of modes. Additionally, it is shown that the refractive-index relative difference at the core center is one of the most preponderant parameters, allowing to reduce the DMD at the expense of increasing MBL. Finally, the optimum DMD obtained for 12 LP modes is lower than 3 ps/km. © 2014 IEEE.
Resumo:
In this paper, we investigate the design of few-mode fibers (FMFs) guiding 2 to 12 linearly polarized (LP) modes with low differential mode delay (DMD) over the C-band, suitable for long-haul transmission. Two different types of refractive index profile have been considered: a graded-core with a cladding trench (GCCT) profile and a multi-step-index (MSI) profile. The profiles parameters are optimized in order to achieve: the lowest possible DMD and macro-bend losses (MBL) lower than the ITU-T standard recommendation. The optimization results show that the MSI profiles present lower DMD than the minimum achieved with a GCCT profile. Moreover, it is shown that the optimum DMD and the MBL scale with the number of modes for both profiles. The optimum DMD obtained for 12 LP modes is lower than 3 ps/km using a GCCT profile and lower than 2.5 ps/km using a MSI profile. The optimization results reveal that the most preponderant parameter of the GCCT profile is the refractive index relative difference at the core center, Δnco. Reducing Δn co, the DMD is reduced at the expense of increasing the MBL. Regarding the MSI profiles, it is shown that 64 steps are required to obtain a DMD improvement considering 12 LP modes. Finally, the impact of the fabrication margins on the optimum DMD is analyzed. The probability of having a manufactured FMF with 12 LP modes and DMD lower than 12 ps/km is approximately 68% using a GCCT profile and 16% using a MSI profile. © 2013 IEEE.
Resumo:
This letter proposes the use of a refractive index profile with a graded core and a cladding trench for the design of few-mode fibers, aiming an arbitrary differential mode delay (DMD) flattened over the C+ L band. By optimizing the core grading exponent and the dimensioning of the trench, a deviation lower than 0.01 ps/km from a target DMD is observed over the investigated wavelength range. Additionally, it is found that the dimensioning of the trench is almost independent of the target DMD, thereby enabling the use of a simple design rule that guarantees a maximum DMD deviation of 1.8 ps/km for a DMD target between-200 and 200 ps/km. © 2012 IEEE.
Resumo:
PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.
Resumo:
We propose and experimentally demonstrate a simple and accurate technique for measuring differential mode group delay (DMGD) in few mode fibers (FMF). A frequency-swept microwave signal is modulated on a filtered optical incoherent source. The microwave signals carried on different fiber modes experience different time delays and interfere with each other in the photodetector. Optical interference between propagating fiber modes is avoided by the use of an incoherent optical source. A mathematical model is established to analyze the interference pattern and extract the DMGD values. A 456-m two-mode fiber and a 981-m FMF, which supports four LP modes, are measured. The measurement covers the whole C-band and the results coincide well with those obtained by the time-of-flight method and the numerical simulations. A precision of ±0.002 ps/m is achieved.
Resumo:
We report for the first time on the limitations in the operational power range of few-mode fiber based transmission systems, employing 28Gbaud quadrature phase shift keying transponders, over 1,600km. It is demonstrated that if an additional mode is used on a preexisting few-mode transmission link, and allowed to optimize its performance, it will have a significant impact on the pre-existing mode. In particular, we show that for low mode coupling strengths (weak coupling regime), the newly added variable power mode does not considerably impact the fixed power existing mode, with performance penalties less than 2dB (in Q-factor). On the other hand, as mode coupling strength is increased (strong coupling regime), the individual launch power optimization significantly degrades the system performance, with penalties up to ∼6dB. Our results further suggest that mutual power optimization, of both fixed power and variable power modes, reduces power allocation related penalties to less than 3dB, for any given coupling strength, for both high and low differential mode delays. © 2013 Optical Society of America.
Resumo:
This letter proposes the introduction of discrete modal crosstalk (XT) through fiber splices for the improvement of the distance reach (DR) of mode division multiplexed (MDM) transmission systems over few mode fibers (FMFs). The proposed method increases the DR, reducing the time spread of the FMFs' impulse response. The effectiveness of this method is assessed through simulation considering 3 × 136-Gbit/s MDM-coherently-detected polarization-multiplexed quadrature-phase-shift-keying ultralong haul transmission systems employing inherently low differential mode delay (DMD) FMFs or DMD compensated FMFs. A maximum DR increase factor of 1.9 is obtained for the optimum number of splices per span and optimum splice XT level. © 1989-2012 IEEE.
Resumo:
The main intend of this work, is to determinate the Specific Absorption Rate (SAR) on human head tissues exposed to radiation caused by sources of 900 and 1800MHz, since those are the typical frequencies for mobile communications systems nowadays. In order to determinate the SAR, has been used the FDTD (Finite Difference Time Domain), which is a numeric method in time domain, obtained from the Maxwell equations in differential mode. In order to do this, a computational model from the human head in two dimensions made with cells of the smallest possible size was implemented, respecting the limits from computational processing. It was possible to verify the very good efficiency of the FDTD method in the resolution of those types of problems.
Resumo:
Tässädiplomityössä selvitettiin taajuusmuuttajan synnyttämien yhteismuotoisten häiriöiden syntyä, ominaisuuksia, kulkureittejä sekä erilaisia tekniikoita toteuttaa yhteismuotosuodatus taajuusmuuttajan lähdössä. Työssä suunniteltiin ja mitoitettiin yhteismuotosuodatin, josta valmistettiin prototyyppi. Suodatinta testattiin laboratoriossa ja mittauksissa käytettiin erilaisia suodattimen kapasitanssin arvoja ja neutraalin pisteen kytkennän variaatioita. Mittauksilla selvitettiin suodattimen kyky suodattaa myös yhteismuotoisten jännitteiden lisäksi eromuotoista jännitettä, akselijännitettä ja vaihevirtaa. Mittaustulosten perusteella voitiin todeta suunnitellun suodattimen parantavan merkittävästi taajuusmuuttajalta moottorille syötettävän sähkön laatua ja loiventavan ennen kaikkea yhteismuotoisen jännitepulssin nousureunaa.
Resumo:
Power electronic converter drives use, for the sake of high efficiency, pulse-width modulation that results in sequences of high-voltage high-frequency steep-edged pulses. Such a signal contains a set of high harmonics not required for control purposes. Harmonics cause reflections in the cable between the motor and the inverter leading to faster winding insulation ageing. Bearing failures and problems with electromagnetic compatibility may also result. Electrical du/dt filters provide an effective solution to problems caused by pulse-width modulation, thereby increasing the performance and service life of the electrical machines. It is shown that RLC filters effectively decrease the reflection phenomena in the cable. Improved (simple, but effective) solutions are found for both differential- and common-mode signals; these solutions use a galvanic connection between the RLC filter star point and the converter DC link. Foil chokes and film capacitors are among the most widely used components in high-power applications. In actual applications they can be placed in different parts of the cabinet. This fact complicates the arrangement of the cabinet and decreases the reliability of the system. In addition, the inductances of connection wires may prevent filtration at high frequencies. This thesis introduces a new hybrid LC filter that uses a natural capacitance between the turns of the foil choke based on integration of an auxiliary layer into it. The main idea of the hybrid LC filter results from the fact that both the foil choke and the film capacitors have the same roll structure. Moreover, the capacitance between the turns (“intra capacitance”) of the foil inductors is the reason for the deterioration of their properties at high frequencies. It is shown that the proposed filter has a natural cancellation of the intra capacitance. A hybrid LC filter may contain two or more foil layers isolated from each other and coiled on a core. The core material can be iron or even air as in the filter considered in this work. One of the foils, called the main foil, can be placed between the inverter and the motor cable. Other ones, called auxiliary foils, may be connected in star to create differential-mode noise paths, and then coupled to the DC link midpoint to guarantee a traveling path, especially for the common-mode currents. This way, there is a remarkable capacitance between the main foil and the auxiliary foil. Investigations showed that such a system can be described by a simple equivalent LC filter in a wide range of frequencies. Because of its simple hybrid construction, the proposed LC filter can be a cost-effective and competitive solution for modern power drives. In the thesis, the application field of the proposed filter is considered and determined. The basics of hybrid LC filter design are developed further. High-frequency behaviour of the proposed filter is analysed by simulations. Finally, the thesis presents experimental data proving that the hybrid LC filter can be used for du/dt of PWM pulses and reduction of common-mode currents.
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.
Resumo:
A fast and robust analytical method for amperometric determination of hydrogen peroxide (H(2)O(2)) based on batch injection analysis (BIA) on an array of gold microelectrodes modified with platinum is proposed. The gold microelectrode array (n = 14) was obtained from electronic chips developed for surface mounted device technology (SMD), whose size offers advantages to adapt them in batch cells. The effect of the dispensing rate, volume injected, distance between the platinum microelectrodes and the pipette tip, as well as the volume of solution in the cell on the analytical response were evaluated. The method allows the H(2)O(2) amperometric determination in the concentration range from 0.8 mu mol L(-1) to 100 mu mol L(-1). The analytical frequency can attain 300 determinations per hour and the detection limit was estimated in 0.34 mu mol L(-1) (3 sigma). The anodic current peaks obtained after a series of 23 successive injections of 50 mu L of 25 mu mol L(-1) H(2)O(2) showed an RSD < 0.9%. To ensure the good selectivity to detect H(2)O(2), its determination was performed in a differential mode, with selective destruction of the H(2)O(2) with catalase in 10 mmol L(-1) phosphate buffer solution. Practical application of the analytical procedure involved H(2)O(2) determination in rainwater of Sao Paulo City. A comparison of the results obtained by the proposed ampermetric method with another one which combines flow injection analysis (FIA) with spectrophotometric detection showed good agreement. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Through out the course of a steady increase in search and recovery of space in the coastal zone, there is also an expanding concern about the erosion processes of this area. The main problem in coastal areas is that urbanization occurs in a disorderly fashion and unsustainable, further aggravating the problems of coastal dynamics. The study area of this work is located on the southern coast of Pirangi do Norte beach to about 20km south of Natal, capital of Rio Grande do Norte in the Parnamirim City. This area has the length of approximately 1km, divided into three sections (Western, Central and Eastern) with a morphology consisting of a tableland at the top, sea cliffs in the West and Central parts and sand dunes in the Eastern section, both vegetated, and a coastal plain on the inferior part associated with the presence of beach rocks. This study aimed to analyze the erosion processes operating in the excerpt of Pirangi do Norte beach and assess the feasibility of their monitoring making use of DGPS (Global Positioning System Differential mode). During the work it was carried out a physical description of the area through photo-interpretation and site survey after measurement of the shoreline in the period between November 2004 and November 2009 and beach profiles between August 2005 and July 2006. The analysis of the results of the annual surveys showed the occurrence of variations of the shoreline along the stretch traveled. Sites are identified in advancement coast from the sea and it was verified in loco the presence of erosion with deposition of materials on the lower part of the coastal bluff, the former position of the shoreline, showing a false notion of advancing it. This leads to the conclusion that the data collected in a survey of the shoreline should always be accompanied by photographic records of the local area and with the highest rate of erosion, thus avoiding the mistake of treating the deposit materials as evidence of progress coast. At the end of the study, after a review of various works to mitigate the erosion in the coastal zone, it is recommended to the area of study the adoption of an artificial feeding of the beach, aiming the minimization of the erosive effects of the tides. Moreover, it is suggested that even the continuity of monitoring, maintenance of existing vegetation and control of the occupation on the edge of sea cliffs
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].