997 resultados para Desgaste de restauração dentária


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To compare the abrasion wear resistance and superficial roughness of different glass ionomer cements used as restorative materials, focusing on a new nanoparticulate material. Material and Method: Three glass ionomer cements were evaluated: Ketac Molar, Ketac N100 and Vitremer (3M ESPE, St. Paul, MN, USA), as well as the Filtek Z350 (3M ESPE, St. Paul, MN, USA). For each material were fabricated circular specimens (n=12), respecting the handling mode specified by the manufacturer, which were polished with sandpaper disks of decreasing grit. The wear was determined by the amount of mass (M) lost after brushing (10,000 cycles) and the roughness (Ra) using a surface roughness tester. The difference between the Minitial and Mfinal (ΔM) as well as beroughness of aesthetic restorative materials: an in vitro comparison. SADJ. 2001; 56(7): 316-20. 11. Yip HK, Peng D, Smales RJ. Effects of APF gel on the physical structure of compomers and glass ionomer cements. Oper. Dent. 2001; 26(3): 231-8. 12. Ma T, Johnson GH, Gordon GE. Effects of chemical disinfectants on the surface characteristics and color of denture resins. J Prosthet Dent 1997; 77(2): 197-204. 13. International organization for standardization. Technical specification 14569-1. Dental Materials – guidance on testing of wear resistance – PART I: wear by tooth brushing. Switzerland: ISO; 1999. 14. Bollen CML, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater.1997; 13(4): 258-9. 15. Kielbassa AM, Gillmann C, Zantner H, Meyer-Lueckel H, Hellwig E, Schulte-Mönting J. Profilometric and microradiographic studies on the effects of toothpaste and acidic gel abrasivity on sound and demineralized bovine dental enamel. Caries Res. 2005; 39(5): 380-6. 16. Tanoue N, Matsumara H, Atsuta M. Wear and surface roughness of current prosthetic composites after toothbrush/dentifrice abrasion. J Prosthet Dent. 2000; 84(1): 93-7. 17. Heath JR, Wilson HJ. Abrasion of restorative materials by toothpaste. J Oral Rehabil. 1976; 3(2): 121-38. 18. Frazier KB, Rueggeberg FA, Mettenburg DJ. Comparasion of wearresistance of class V restorative materials. J Esthet Dent. 1998; 10(6): 309-14. 19. Momoi Y, Hirosakil K, Kohmol A, McCabe JF. In vitro toothebrushdentifrrice abrasion of resin-modified glass ionomers. Dent Mater. 1997; 13(2): 82-8. 20. Turssi CP, Magalhães CS, Serra MC, Rodrigues Jr.AL. Surface roughness assessment of resin-based materials during brushing preceded by pHcycling simulations. Oper Dent. 2001; 26(6): 576-84. 21. Wang L, Cefaly DF, Dos Santos JL, Dos Santos JR, Lauris JR, Mondelli RF, et al. In vitro interactions between lactic acid solution and art glassionomer cements. J Appl Oral Sci. 2009; 17(4): 274-9. 22. Carvalho FG, Fucio SB, Paula AB, Correr GM, Sinhoreti MA, PuppinRontani RM. Child toothbrush abrasion effect on ionomeric materials. J Dent Child (Chic). 2008; 75(2): 112-6. 23. Coutinho E, Cardoso MV, De Munck J, Neves AA, Van Landuyt KL, Poitevin A, et al. Bonding effectiveness and interfacial characterization of a nano-filled resin-modified glass-ionomer. Dent Mater. 2009; 25(11): 1347-57. tween Rainitial and Rafinal (ΔRa) were also used for statistical analysis (α=0.05). Results: Except for the composite, significant loss of mass was observed for all glass ionomer cements and the ΔM was comparable for all of them. Significant increase in roughness was observed only for Vitremer and Ketac N100. At the end of the brushing cycle, just Vitremer presented surface roughness greater than the composite resin. Conclusion: All glass ionomer cements showed significant weight loss after 10,000 cycles of brushing. However, only Vitremer showed an increase of roughness greater than the Z350 resin, while the nanoparticulate cement Ketac N100 showed a smooth surface comparable to the composite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: frequentemente, os pacientes ortodônticos apresentam restaurações de resina composta; no entanto, existem poucos estudos que avaliam a melhor forma de colagem ortodôntica nessa situação. OBJETIVO: o objetivo do presente trabalho foi avaliar a força adesiva de braquetes ortodônticos em restaurações resinosas com tratamento de superfície. MÉTODOS: foram utilizados 51 incisivos inferiores bovinos divididos aleatoriamente em três grupos. No grupo controle (GC), os braquetes foram colados em esmalte dentário; nos grupos experimentais com tratamento (GCT) e sem tratamento (GST), os braquetes foram colados em restauração de resina previamente realizada, diferenciando-se pelo tratamento de superfície com broca diamantada. Os dentes foram incluídos em tubos de PVC com resina acrílica autopolimerizável. O ensaio de cisalhamento foi executado em máquina universal de ensaios Emic. Os grupos foram submetidos à ANOVA com pós-teste de Tukey para verificação da diferença estatística entre os grupos (α = 0,05). RESULTADOS: GC (6,62MPa) e GCT (6,82MPa) apresentaram resultados semelhantes, enquanto o GST (5,07MPa) obteve resultados estatisticamente menores (p < 0,05). CONCLUSÃO: conclui-se que a melhor técnica de colagem de braquetes ortodônticos em restaurações de resina composta é a de realização de desgaste sobre a superfície.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The composite resin is the material of election for direct restorations in posterior teeth currently. The restorative dentistry aims to improve each day the material and facilitate the restorative technique. This paper describes the technique of occlusal matrix made to speed up and preservation the occlusal surface of a first molar tooth affected by caries lesion. A new resin-based composite was used called Silorane, which may be placed in larger increments due the material has low shrinkage and polymerization stress. The use of occlusal matrix associated with a low shrinkage resin composite can simplify the clinical work, and result in a restoration with excellent reproduction of anatomical.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A erosão dentária é o resultado físico da perda patológica, crónica e localizada de tecidos dentários mineralizados, provocada quimicamente por ácidos e/ou quelantes, sem envolvimento bacteriano. O diagnóstico diferencial das lesões de erosão dentária deve ser feito o mais precocemente possível, sendo que as suas características clínicas dificilmente se dissociam de fenómenos de atrição e/ou de abrasão. Desta forma é importante o uso de índices de abordagem do desgaste dentário não demasiado discriminatórios, mas que possam ser válidos num âmbito clínico para monitorizar o desgaste, e avaliar a eficácia das medidas preventivas instituídas. A intervenção clínica face á perda estrutural de causa erosiva implica o controlo dos fatores etiológicos nomeadamente dietéticos, comportamentais e patológicos, associado a um aporte diário de agentes de reforço da estrutura dentária. O objectivo deste trabalho foi realizar uma pesquisa bibliográfica de forma a sistematizar os pontos importantes a ter em conta na abordagem clínica das lesões erosivas. Este tema torna-se importante e útil dado que estes conhecimentos podem ser aplicados diariamente na prática clínica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

FUNDAMENTO: A literatura é controversa no que se refere ao uso de vasoconstritores para anestesia local em cardiopatas, havendo preocupação com a indução de descompensação cardíaca. OBJETIVO: Avaliar parâmetros eletrocardiográficos e de pressão arterial durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em portadores de doença arterial coronária. MÉTODOS: Neste estudo foram avaliados 62 pacientes. As idades variaram de 39 a 80 anos (média de 58,7 + 8,8) anos, sendo 51 pacientes (82,3%) do sexo masculino. Do total de pacientes, 30 foram randomizados para receber anestesia com lidocaína 2% com adrenalina (grupo LCA) e os demais para lidocaína 2% sem vasoconstritor (grupo LSA). Todos foram submetidos a monitorização ambulatorial da pressão arterial e eletrocardiografia dinâmica por 24 horas. Foram considerados três períodos: 1) basal (registros obtidos durante os 60 minutos que antecederam o procedimento); 2) procedimento (registros obtidos desde o início da anestesia até o final do procedimento) e 3) das 24 horas. RESULTADOS: Houve elevação da pressão arterial do período basal para o procedimento nos dois grupos quando analisados separadamente; quando confrontados, não apresentaram diferença entre si. A freqüência cardíaca não se alterou nos dois grupos. Depressão do segmento ST > 1 mm não ocorreu durante os períodos basal e procedimento. Arritmias em número superior a 10 por hora estiveram presentes durante o procedimento em sete pacientes (12,5%), sendo quatro (13,8%) do grupo que recebeu anestesia sem adrenalina e três (11,1%) do grupo com adrenalina. CONCLUSÃO: Não houve diferença em relação a comportamento da pressão arterial, freqüência cardíaca, evidência de isquemia e arritmias entre os grupos. O uso de vasoconstritor mostrou-se seguro dentro dos limites do estudo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste trabalho realizou-se um estudo de caracterização metalúrgica do amálgama dentário Dispersalloy produzido pela empresa Dentsply Ind. e Com. Ltda., por meio da análise da sua composição química, utilizando-se a técnica espectrofotométrica de absorção atômica, procedendo-se em seguida, a análise metalográfica, utilizando-se microscopia eletrônica de varredura. A seguir, foi realizado um estudo de resistência à corrosão, utilizando-se técnicas eletroquímicas tradicionais de polarização e espectroscopia de impedância, em meio e condições que simulam a agressividade do ambiente bucal. Para isto, as amostras foram obtidas pelo processo de amalgamação mecânica, método usualmente utilizado pelos dentistas no próprio consultório, para a preparação da restauração dentária. A liga comercial Dispersalloy, representante da categoria de amálgamas de alto teor de cobre, tipo fase dispersa, foi escolhida para este estudo por ser bastante comercializada nos mercados nacional e internacional e, também por ser uma liga metálica moderna, bastante estudada, mas que ainda sofre corrosão no meio bucal.