1000 resultados para DIPSTICK TEST
Resumo:
The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.
Resumo:
We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.
Resumo:
The direct agglutination test (DAT) based on a freeze-dried antigen and the rK39 dipstick test were evaluated for the sero-diagnosis of visceral leishmaniasis (VL). The sensitivity and specificity of both tests were determined using sera from confirmed VL patients (n = 21), healthy controls (n = 19) and from patients with other confirmed infectious diseases (n = 42). The DAT had a sensitivity and a specificity of 100%. The rK39 had a sensitivity of 85.7% and a specificity of 82%. Both tests were also used to screen blood samples of confirmed VL patients (n = 15) and serum samples of VL suspects (n = 61). The DAT found all blood samples of confirmed VL patients positive and tested 98.4% of the serum samples of the VL suspects positive. In contrast, rK39 detected in 9/15 blood samples (60%) antibodies against Leishmania chagasi and found 85.3% of the serum samples of the suspected patients positive. Although the rK39 dipstick is more rapid and user friendlier than the DAT, the latter has a superior sensitivity and specificity. Furthermore, the reagents used for DAT do not require cold storage, whereas the buffer of the rK39 must be stored at 4ºC. Therefore, the DAT is the most suitable test for the sero-diagnosis of VL under field conditions.
Resumo:
Current visceral leishmaniasis (VL) control programs in Brazil include the infected dog elimination but, despite this strategy, the incidence of human VL is still increasing. One of the reasons is the long delay between sample collection, analysis, control implementation and the low sensitivity of diagnostic tests. Due to the high prevalence of asymptomatic dogs, the diagnosis of these animals is important considering their vector infection capacity. Hence, a rapid and accurate diagnosis of canine visceral leishmaniasis is essential for an efficient surveillance program. In this study we evaluated the performance of rK39 antigen in an immunochromatographic format to detect symptomatic and asymptomatic Leishmania chagasi infection in dogs and compared the results with those using a crude antigen ELISA. The sensitivity of rK39 dipstick and ELISA were 83% vs. 95%, respectively, while the specificity was both 100%. Our results also demonstrated that the dipstick test was able to detect infected dogs presenting different clinical forms. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
To determine which species and populations of Anopheles transmit malaria in any given situation, immunological assays for malaria sporozoite antigen can replace traditional microscopical examination of freshly dissected Anopheles. We developed a wicking assay for use with mosquitoes that identifies the presence or absence of specific peptide epitopes of circumsporozoite (CS) protein of Plasmodium falciparum and two strains of Plasmodium vivax (variants 210 and 247). The resulting assay (VecTest(TM) Malaria) is a rapid, one-step procedure using a 'dipstick' test strip capable of detecting and distinguishing between P. falciparum and P. vivax infections in mosquitoes. The objective of the present study was to test the efficacy, sensitivity, stability and field-user acceptability of this wicking dipstick assay. In collaboration with 16 test centres world-wide, we evaluated more than 40 000 units of this assay, comparing it to the standard CS ELISA. The 'VecTest(TM) Malaria' was found to show 92% sensitivity and 98.1% specificity, with 97.8% accuracy overall. In accelerated storage tests, the dipsticks remained stable for >15 weeks in dry conditions up to 45degreesC and in humid conditions up to 37degreesC. Evidently, this quick and easy dipstick test performs at an acceptable level of reliability and offers practical advantages for field workers needing to make rapid surveys of malaria vectors.
Resumo:
INTRODUCTION: Various methods are used for the diagnosis of visceral leishmaniasis (VL), such as microscopic examination, culture and inoculation of laboratory animals; however, serological assays are commonly used for the detection of antibodies in serum samples with a wide range of specificity and sensitivity. METHODS: The purpose of this study was to compare three serological methods, including rA2-ELISA, the recombinant KE16 (rKE16) dipstick test and the direct agglutination test (DAT), for the detection of antibodies against VL antigens. The assays utilized 350 statistically based random serum samples from domestic dogs with clinical symptoms as well as samples from asymptomatic and healthy dogs from rural and urban areas of the Meshkinshahr district, northwestern Iran. RESULTS: Samples were assessed, and the following positive rates were obtained: 11.5% by rKE16, 26.9% by DAT and 49.8% by ELISA. The sensitivity among symptomatic dogs was 32.4% with rKE16, 100% with DAT and 52.9% with ELISA. Conversely, rA2-ELISA was less specific for asymptomatic dogs, at 46.5%, compared with DAT, at 88.9%. CONCLUSIONS : This study recommends rA2-ELISA as a parallel assay combined with DAT to detect VL infection among dogs. Further evaluations should be performed to develop an inexpensive and reliable serologic test for the detection of Leishmania infantum among infected dogs.
Resumo:
BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.
Resumo:
HIV/AIDS-associated visceral leishmaniasis may display the characteristics of an aggressive disease or without specific symptoms at all, thus making diagnosis difficult. The present study describes the results of diagnostic tests applied to a series of suspected VL cases in HIV-infected/AIDS patients admitted in referral hospitals in Pernambuco, Brazil. From a total of 14 eligible patients with cytopenias and/or fever of an unknown etiology, and indication of bone marrow aspirate, 10 patients were selected for inclusion in the study. Diagnosis was confirmed by the following examinations: Leishmania detection in bone marrow aspirate, direct agglutination test, indirect immunofluorescence, rK39 dipstick test, polymerase chain reaction and latex agglutination test. Five out of the ten patients were diagnosed with co-infection. A positive direct agglutination test was recorded for all five co-infected patients, the Leishmania detection and latex agglutination tests were positive in four patients, the rK39 dipstick test in three, the indirect immunofluorescence in two and a positive polymerase chain reaction was recorded for one patient. This series of cases was the first to be conducted in Brazil using this set of tests in order to detect co-infection. However, no consensus has thus far been reached regarding the most appropriate examination for the screening and monitoring of this group of patients.
Resumo:
This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.
Resumo:
La proteinuria è un marker di danno renale nel cane. L’obiettivo dello studio è di valutare la capacità del dipstick urinario e dell’UPC di diagnosticare precocemente l’albuminuria nel cane. Sono stati raccolti 868 campioni di urina, con sedimento spento e assenza di ematuria, nell’Ospedale Didattico Veterinario della Facoltà di Medicina Veterinaria di Bologna. Per 550 campioni è stata effettuata l’analisi delle urine, la misurazione dell’UPC e dell’UAC, mentre UPC e UAC sono stati misurati in tutti gli 868 campioni. I campioni di urina sono stati analizzati con il metodo dipstick mediante lettura automatizzata. Utilizzando come valore di riferimento l’UAC è stata valutata l’accuratezza diagnostica del dipstick urinario e dell’UPC. L’intervallo di riferimento dell’UAC (0-0,024) è stato determinato utilizzando 60 cani sani. I dati raccolti sono stati classificati utilizzando differenti cut-off per il peso specifico urinario (1012 o 1030), per la proteinuria al dipstick (30 o 100 mg/dl), per l’UPC (0,2) e per l’UAC (0,024). Sono stati valutati l’agreement diagnostico e la correlazione di Spearman tra dipstick, UPC e UAC. E’ stata stimata l’accuratezza diagnostica misurando l’area al di sotto della curva di ROC nell’analisi dell’UAC. Il livello di significatività è stato definito per p < 0,05. Indipendentemente dal peso specifico urinario, l’agreement diagnostico tra dipstick, UPC e UAC è risultato forte (k=0,62 e k=0,61, rispettivamente; p<0,001) con valori di dipstick ≥30 mg/dl, debole (k=0,27 e k=0,26, rispettivamente; p<0,001) con valori di dipstick ≥100 mg/dl. L’accuratezza diagnostica del dipstick messa a confronto con UPC e con UAC è molto buona (AUC 0,84 e 0,84, rispettivamente; p<0,001) e i risultati negativi al dipstick presentano il 100% di sensitività. UPC e UAC sono fortemente correlate (r=0,90; p<0,001). Mettendo a confronto UPC e UAC, l’accuratezza diagnostica è risultata eccellente (AUC 0,94; p<0,001), con massima sensitività e specificità per UPC≥0.3.
Resumo:
The dinoflagellates of Alexandrium genus are known to be producers of paralytic shellfish toxins that regularly impact the shellfish aquaculture industry and fisheries. Accurate detection of Alexandrium including A. minutum is crucial for environmental monitoring and sanitary issues. In this study, we firstly developed a quantitative lateral flow immunoassay (LFIA) using super-paramagnetic nanobeads for A. minutum whole cells. This dipstick assay relies on two distinct monoclonal antibodies used in a sandwich format and directed against surface antigens of this organism. No sample preparation is required. Either frozen or live cells can be detected and quantified. The specificity and sensitivity are assessed by using phytoplankton culture and field samples spiked with a known amount of cultured A. minutum cells. This LFIA is shown to be highly specific for A. minutum and able to detect reproducibly 105 cells/L within 30 min. The test is applied to environmental samples already characterized by light microscopy counting. No significant difference is observed between the cell densities obtained by these two methods. This handy super-paramagnetic lateral flow immnunoassay biosensor can greatly assist water quality monitoring programs as well as ecological research.
Resumo:
The aim of the study was to develop a culturally adapted translation of the 12-item smell identification test from Sniffin' Sticks (SS-12) for the Estonian population in order to help diagnose Parkinson's disease (PD). A standard translation of the SS-12 was created and 150 healthy Estonians were questioned about the smells used as response options in the test. Unfamiliar smells were replaced by culturally familiar options. The adapted SS-12 was applied to 70 controls in all age groups, and thereafter to 50 PD patients and 50 age- and sex-matched controls. 14 response options from 48 used in the SS-12 were replaced with familiar smells in an adapted version, in which the mean rate of correct response was 87% (range 73-99) compared to 83% with the literal translation (range 50-98). In PD patients, the average adapted SS-12 score (5.4/12) was significantly lower than in controls (average score 8.9/12), p < 0.0001. A multiple linear regression using the score in the SS-12 as the outcome measure showed that diagnosis and age independently influenced the result of the SS-12. A logistic regression using the SS-12 and age as covariates showed that the SS-12 (but not age) correctly classified 79.0% of subjects into the PD and control category, using a cut-off of <7 gave a sensitivity of 76% and specificity of 86% for the diagnosis of PD. The developed SS-12 cultural adaption is appropriate for testing olfaction in Estonia for the purpose of PD diagnosis.