992 resultados para Current reference


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of normal heart weight ranges is important information for pathologists. Comparing the measured heart weight to reference values is one of the key elements used to determine if the heart is pathological, as heart weight increases in many cardiac pathologies. The current reference tables are old and in need of an update. AIMS: The purposes of this study are to establish new reference tables for normal heart weights in the local population and to determine the best predictive factor for normal heart weight. We also aim to provide technical support to calculate the predictive normal heart weight. METHODS: The reference values are based on retrospective analysis of adult Caucasian autopsy cases without any obvious pathology that were collected at the University Centre of Legal Medicine in Lausanne from 2007 to 2011. We selected 288 cases. The mean age was 39.2 years. There were 118 men and 170 women. Regression analyses were performed to assess the relationship of heart weight to body weight, body height, body mass index (BMI) and body surface area (BSA). RESULTS: The heart weight increased along with an increase in all the parameters studied. The mean heart weight was greater in men than in women at a similar body weight. BSA was determined to be the best predictor for normal heart weight. New reference tables for predicted heart weights are presented as a web application that enable the comparison of heart weights observed at autopsy with the reference values. CONCLUSIONS: The reference tables for heart weight and other organs should be systematically updated and adapted for the local population. Web access and smartphone applications for the predicted heart weight represent important investigational tools.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of normal heart weight ranges is important information for pathologists. Comparing the measured heart weight to reference values is one of the key elements used to determine if the heart is pathological, as heart weight increases in many cardiac pathologies. The current reference tables are old and in need of an update. AIMS: The purposes of this study are to establish new reference tables for normal heart weights in the local population and to determine the best predictive factor for normal heart weight. We also aim to provide technical support to calculate the predictive normal heart weight. METHODS: The reference values are based on retrospective analysis of adult Caucasian autopsy cases without any obvious pathology that were collected at the University Centre of Legal Medicine in Lausanne from 2007 to 2011. We selected 288 cases. The mean age was 39.2 years. There were 118 men and 170 women. Regression analyses were performed to assess the relationship of heart weight to body weight, body height, body mass index (BMI) and body surface area (BSA). RESULTS: The heart weight increased along with an increase in all the parameters studied. The mean heart weight was greater in men than in women at a similar body weight. BSA was determined to be the best predictor for normal heart weight. New reference tables for predicted heart weights are presented as a web application that enable the comparison of heart weights observed at autopsy with the reference values. CONCLUSIONS: The reference tables for heart weight and other organs should be systematically updated and adapted for the local population. Web access and smartphone applications for the predicted heart weight represent important investigational tools.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents the analysis and the design of a peak-current-controlled high-power-factor boost rectifier, with slope compensation, operating at constant frequency. The input current shaping is achieved, with continuous inductor current mode, with no multiplier to generate a current reference. The resulting overall circuitry is very simple, in comparison with the average-current-controlled boost rectifier. Experimental results are presented, taken from a laboratory prototype rated at 370 W and operating at 67 kHz. The measured power factor was 0.99, with a input current THD equal to 5.6%, for an input voltage THD equal to 2.26%.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Urinary creatinine excretion is used as a marker of completeness of timed urine collections, which are a keystone of several metabolic evaluations in clinical investigations and epidemiological surveys. The current reference values for 24-hour urinary creatinine excretion rely on observations performed in the 1960s and 1970s in relatively small and mostly selected groups, and may thus poorly fit to the present-day general European population. The aim of this study was to establish and validate anthropometry-based age- and sex-specific reference values of the 24-hour urinary creatinine excretion on adult populations with preserved renal function. METHODS We used data from two independent Swiss cross-sectional population-based studies with standardised 24-hour urinary collection and measured anthropometric variables. Only data from adults of European descent, with estimated glomerular filtration rate (eGFR) ≥60 ml/min/1.73 m(2) and reported completeness of the urinary collection were retained. A linear regression model was developed to predict centiles of the 24-hour urinary creatinine excretion in 1,137 participants from the Swiss Survey on Salt and validated in 994 participants from the Swiss Kidney Project on Genes in Hypertension. RESULTS The mean urinary creatinine excretion was 193 ± 41 μmol/kg/24 hours in men and 151 ± 38 μmol/kg/24 hours in women in the Swiss Survey on Salt. The values were inversely correlated with age and body mass index (BMI). Based on current reference values (177 to 221 μmol/kg/24 hours in men and 133 to 177 μmol/kg/24 hours in women), 56% of the urinary collections in the whole population and 67% in people >60 years old would have been considered as inaccurate. A linear regression model with sex, BMI and age as predictor variables was found to provide the best prediction of the observed values and showed a good fit when applied to the validation population. CONCLUSIONS We propose a validated prediction equation for 24-hour urinary creatinine excretion in the general European population, based on readily available variables such as age, sex and BMI, and a few derived normograms to ease its clinical application. This should help healthcare providers to interpret the completeness of a 24-hour urine collection in daily clinical practice and in epidemiological population studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Organização Mundial de Saúde tem hoje duas classificações de referência para a descrição dos estados de saúde: a Classificação Estatística Internacional de Doenças e Problemas Relacionados à Saúde, que corresponde à décima revisão da Classificação Internacional de Doenças (CID-10) e a Classificação Internacional de Funcionalidade, Incapacidade e Saúde (CIF). A utilização da CIF vem sendo aguardada com grande expectativa pelas organizações de pessoas com deficiências e instituições relacionadas. A falta de definição clara de "deficiência" ou "incapacidade" tem sido apontada como um impedimento para a promoção de saúde de pessoas com deficiência. É importante que essas definições, especialmente no âmbito legislativo e regulamentar, sejam consistentes e se fundamentem num modelo coerente sobre o processo que origina as situações de incapacidade. Este artigo tem como objetivo apresentar elementos da CID-10 e da CIF, e o papel que desempenham para definir deficiência e incapacidade. Os componentes da CIF podem contribuir para diferentes campos de aplicabilidade no que diz respeito ao entendimento das definições de deficiência ou incapacidade a partir do conceito de funcionalidade e dos fatores contextuais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Organização Mundial de Saúde tem hoje duas classificações de referência para a descrição dos estados de saúde: a Classificação Estatística Internacional de Doenças e Problemas Relacionados à Saúde, que corresponde à décima revisão da Classificação Internacional de Doenças (CID-10) e a Classificação Internacional de Funcionalidade, Incapacidade e Saúde (CIF). A utilização da CIF vem sendo aguardada com grande expectativa pelas organizações de pessoas com deficiências e instituições relacionadas. A falta de definição clara de "deficiência" ou "incapacidade" tem sido apontada como um impedimento para a promoção de saúde de pessoas com deficiência. É importante que essas definições, especialmente no âmbito legislativo e regulamentar, sejam consistentes e se fundamentem num modelo coerente sobre o processo que origina as situações de incapacidade. Este artigo tem como objetivo apresentar elementos da CID-10 e da CIF, e o papel que desempenham para definir deficiência e incapacidade. Os componentes da CIF podem contribuir para diferentes campos de aplicabilidade no que diz respeito ao entendimento das definições de deficiência ou incapacidade a partir do conceito de funcionalidade e dos fatores contextuais

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The purpose of the optic nerve sheath diameter (ONSD) research group project is to establish an individual patient-level database from high quality studies of ONSD ultrasonography for the detection of raised intracranial pressure (ICP), and to perform a systematic review and an individual patient data meta-analysis (IPDMA), which will provide a cutoff value to help physicians making decisions and encourage further research. Previous meta-analyses were able to assess the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP but failed to determine a precise cutoff value. Thus, the ONSD research group was founded to synthesize data from several recent studies on the subject and to provide evidence on the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP. METHODS: This IPDMA will be conducted in different phases. First, we will systematically search for eligible studies. To be eligible, studies must have compared ONSD ultrasonography to invasive intracranial devices, the current reference standard for diagnosing raised ICP. Subsequently, we will assess the quality of studies included based on the QUADAS-2 tool, and then collect and validate individual patient data. The objectives of the primary analyses will be to assess the diagnostic accuracy of ONSD ultrasonography and to determine a precise cutoff value for detecting raised ICP. Secondly, we will construct a logistic regression model to assess whether patient and study characteristics influence diagnostic accuracy. DISCUSSION: We believe that this IPD MA will provide the most reliable basis for the assessment of diagnostic accuracy of ONSD ultrasonography for detecting raised ICP and to provide a cutoff value. We also hope that the creation of the ONSD research group will encourage further study. TRIAL REGISTRATION: PROSPERO registration number: CRD42012003072.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent grammars and dictionaries also (`therefore, so, well¿) continues to be preferably presented as an adverb with a conclusive-consecutive connective function that essentially corresponds to its use in formal written German. Its function as a modal particle is documented, however, since the beginnings of what is known as Partikelforschung, though not all its uses have been systematically investigated contrasting oral and written German, either in mode or concept. In this article we analyse the uses of also in semi-informal oral interactions on the basis of empirical data (from a subsample of the VARCOM corpus). Specifically, we will analyse the presence and frequency of also at the beginning of a sentence or sequence, the functions it serves as a logical-semantic connector or discourse and interaction marker and the interrelations between these functions, in order to contrast these results with the description of also provided by current reference works.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ultrasound image reconstruction from the echoes received by an ultrasound probe after the transmission of diverging waves is an active area of research because of its capacity to insonify at ultra-high frame rate with large regions of interest using small phased arrays as the ones used in echocardiography. Current state-of-the-art techniques are based on the emission of diverging waves and the use of delay and sum strategies applied on the received signals to reconstruct the desired image (DW/DAS). Recently, we have introduced the concept of Ultrasound Fourier Slice Imaging (UFSI) theory for the reconstruction of ultrafast imaging for linear acquisition. In this study, we extend this theory to sectorial acquisition thanks to the introduction of an explicit and invertible spatial transform. Starting from a diverging wave, we show that the direct use of UFSI theory along with the application of the proposed spatial transform allows reconstructing the insonified medium in the conventional Cartesian space. Simulations and experiments reveal the capacity of this new approach in obtaining competitive quality of ultrafast imaging when compared with the current reference method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Genome sequence varies in numerous ways among individuals although the gross architecture is fixed for all humans. Retrotransposons create one of the most abundant structural variants in the human genome and are divided in many families, with certain members in some families, e.g., L1, Alu, SVA, and HERV-K, remaining active for transposition. Along with other types of genomic variants, retrotransponson-derived variants contribute to the whole spectrum of genome variants in humans. With the advancement of sequencing techniques, many human genomes are being sequenced at the individual level, fueling the comparative research on these variants among individuals. In this thesis, the evolution and functional impact of structural variations is examined primarily focusing on retrotransposons in the context of human evolution. The thesis comprises of three different studies on the topics that are presented in three data chapters. First, the recent evolution of all human specific AluYb members, representing the second most active subfamily of Alus, was tracked to identify their source/master copy using a novel approach. All human-specific AluYb elements from the reference genome were extracted, aligned with one another to construct clusters of similar copies and each cluster was analyzed to generate the evolutionary relationship between the members of the cluster. The approach resulted in identification of one major driver copy of all human specific Yb8 and the source copy of the Yb9 lineage. Three new subfamilies within the AluYb family – Yb8a1, Yb10 and Yb11 were also identified, with Yb11 being the youngest and most polymorphic. Second, an attempt to construct a relation between transposable elements (TEs) and tandem repeats (TRs) was made at a genome-wide scale for the first time. Upon sequence comparison, positional cross-checking and other relevant analyses, it was observed that over 20% of all TRs are derived from TEs. This result established the first connection between these two types of repetitive elements, and extends our appreciation for the impact of TEs on genomes. Furthermore, only 6% of these TE-derived TRs follow the already postulated initiation and expansion mechanisms, suggesting that the others are likely to follow a yet-unidentified mechanism. Third, by taking a combination of multiple computational approaches involving all types of genetic variations published so far including transposable elements, the first whole genome sequence of the most recent common ancestor of all modern human populations that diverged into different populations around 125,000-100,000 years ago was constructed. The study shows that the current reference genome sequence is 8.89 million base pairs larger than our common ancestor’s genome, contributed by a whole spectrum of genetic mechanisms. The use of this ancestral reference genome to facilitate the analysis of personal genomes was demonstrated using an example genome and more insightful recent evolutionary analyses involving the Neanderthal genome. The three data chapters presented in this thesis conclude that the tandem repeats and transposable elements are not two entirely distinctly isolated elements as over 20% TRs are actually derived from TEs. Certain subfamilies of TEs themselves are still evolving with the generation of newer subfamilies. The evolutionary analyses of all TEs along with other genomic variants helped to construct the genome sequence of the most recent common ancestor to all modern human populations which provides a better alternative to human reference genome and can be a useful resource for the study of personal genomics, population genetics, human and primate evolution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’effort physique a été reconnu comme l’un des déterminants majeurs qui affecte l’absorption pulmonaire et la cinétique des solvants industriels, composés volatils très répandus dans le milieu de travail. L’objectif global de ce projet était de caractériser la relation entre divers niveaux de charge de travail et les concentrations biologiques de l’acétone et du styrène ou de ses métabolites utilisés comme des indicateurs biologiques de l’exposition (IBEs) à ces solvants. Des modèles pharmacocinétiques à base physiologique ont été développés et validés afin de reproduire une exposition professionnelle à l’acétone et au styrène, individuellement et en combinaison, durant une semaine complète de travail (8h/jour, 5 jours). Les simulations ont été effectuées suivant une exposition aux valeurs limite d’exposition (500 ppm et 20 ppm, respectivement) et à des charges de travail de 12,5 W (repos), 25 W et 50 W. Les valeurs prédites par les modèles ont été comparées aux valeurs de référence des IBEs actuels. Le niveau d’acétone dans l’urine obtenu à la fin du dernier quart de travail était 3,5 fois supérieur à la valeur au repos (28 mg/L) pour un effort de 50 W, tandis que les niveaux de styrène dans le sang veineux et de ses métabolites dans l’urine ont augmenté d’un facteur d’environ 3,0 en comparaison avec les valeurs au repos, respectivement de 0,17 mg/L et 144 mg/g créatinine. Pour une co-exposition à des concentrations de 20 ppm de styrène et 200 ppm d’acétone et à une activité physique de 50 W, les simulations ont montré une augmentation de 10% du styrène sanguin et une faible diminution de ses métabolites dans l’urine. Les valeurs simulées par les modèles pour l’acétone ou le styrène montrent que des travailleurs dont la charge de travail équivaut à plus de 25 W sont susceptibles d’avoir des concentrations internes pouvant dépasser les valeurs de référence des IBEs respectifs de ces solvants et peuvent être à risque. Les résultats soulignent ainsi l’importance de tenir compte de la charge de travail dans la détermination d’une valeur de référence pour la surveillance biologique de l’acétone et du styrène.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a new methodology to control the power flow between a distributed generator (DG) and the electrical power distribution grid. It is used the droop voltage control to manage the active and reactive power. Through this control a sinusoidal voltage reference is generated to be tracked by voltage loop and this loop generates the current reference for the current loop. The proposed control introduces feed-forward states improving the control performance in order to obtain high quality for the current injected to the grid. The controllers were obtained through the linear matrix inequalities (LMI) using the D-stability analysis to allocate the closed-loop controller poles. Therefore, the results show quick transient response with low oscillations. Thus, this paper presents the proposed control technique, the main simulation results and a prototype with 1000VA was developed in the laboratory in order to demonstrate the feasibility of the proposed control. © 2012 IEEE.