997 resultados para Contamination during Obturation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The literature suggests that environmental contamination is common during labeled aerosol inhalation procedures in nuclear medicine. We have tested an adherent mask to prevent environmental contamination in 70 procedures. Two groups of patients were evaluated, Group 1 (60 inhalation cases in which the mask was used) presented no environmental contamination in 95% of the procedures (means of 553 dpm and 596 dpm before and after inhalation, p > 0.05, mean of the differences before/after inhalation 6.95, SD = 21.2 dpm) and the only 3 cases in which contamination did occur concerned bearded men; Group 2 (10 inhalation cases in which the mask was not used) showed large increases of environmental radioactive levels in 70% of the procedures (means of 601 dpm and 2,756 dpm before and after inhalation, p < 0.05, mean of the differences 3,066, SD = 2,98 dpm), We conclude that such a mask is very helpful in avoiding environmental contamination during radioaerosol inhalation procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the incidence of Piry virus contamination among surgical instruments used with disposable accessories for phacoemulsification during sequential surgeries. Methods: An experimental model was created with 4 pigs' eyes that were contaminated with Piry virus and 4 pigs' eyes that were not contaminated. Phacoemulsification was performed on the eyes, alternating between the contaminated and non-contaminated eyes. From one surgery to another, the operating fields, gloves, scalpel, tweezers, needles, syringes, tips and bag collector from the phacoemulsification machine were exchanged; only the hand piece and the irrigation and aspiration systems were maintained. Results: In the collector bag, three samples from the contaminated eyes (3/4) were positive, and two samples from the non-contaminated (2/4) eyes were also positive; at the tip, one sample from the contaminated eyes (1/4) and two samples of the noncontaminated eyes (2/4) yielded positive results. In the irrigation system, one sample from a non-contaminated eye (1/4) was positive, and in the aspiration system, two samples from contaminated eyes (2/4) and two samples from non-contaminated eyes (2/4) were positive. In the gloves, the samples were positive in two samples from the non-contaminated eyes (2/4) and in two samples from the contaminated eyes (2/4). In the scalpel samples, three contaminated eyes (3/4) and none of the non-contaminated eyes (0/4) were positive; finally, two samples from the anterior chambers of the non-contaminated eyes gathered after surgery were positive. Conclusions: In two non-contaminated eyes, the presence of genetic material was detected after phacoemulsification surgery, demonstrating that the transmission of the genetic material of the Piry virus occurred at some point during the surgery on these non-contaminated eyes when the hand piece and irrigation and aspiration systems were reused between surgeries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From October 2014 to March 2015, I provided excavation oversight services at a property with substantial environmental concerns. The property in question is located near downtown Seattle and was formerly occupied by the Washington’s first coal gasification plant. The plant operated from 1888 to 1908 and produced coal gas for municipal use. A coal tar like substance with a characteristically high benzene concentration was a byproduct of the coal gasification process and heavily contaminated at or below the surface grade of the plant as shown in previous investigations on the property. Once the plant ceased operation in 1908 the property was left vacant until 1955 when the site was filled in and a service station was built on the property. The main goal of the excavation was not to achieve cleanup on the property, but to properly remove what contaminated soil was encountered during the redevelopment excavation. Areas of concern were identified prior to the commencement of the excavation and an estimation of the extent of contamination on the property was developed. “Hot spots” of contaminated soil associated with the fill placed after 1955 were identified as areas of concern. However, the primary contaminant plume below the property was likely sourced from the coal gasification plant, which operated at an approximate elevation of 20 feet. We planned to constrain the extents of the soil contamination below the property as the redevelopment excavation progressed. As the redevelopment excavation was advanced down to an elevation of approximately 20 feet, soil samples were collected to bound the extents of contamination in the upper portion of the site. The hot spots, known pockets of carcinogenic polycyclic aromatic hydrocarbons (cPAH) located above 20 feet elevation, were excavated as part of the redevelopment excavation. Once a hot spot was excavated, soil samples were collected from the north, south, east, west and bottom sidewalls of the hot spot excavation to check for remaining cPAH. Additionally, four underground storage tanks (USTs) associated with the service station were discovered and subsequently removed. Soil samples were also collected from the resulting UST excavation sidewalls to check for remaining petroleum hydrocarbons. Once the excavation reached its final excavation depth of 20 to 16 feet in elevation, bottom of excavation samples were collected on a 35 foot by 35 foot grid to test for concentrations of contaminants remaining onsite. Once the redevelopment excavation was complete, soils observed from borings drilled for either structural elements, geotechnical wells, or environmental wells were checked for any evidence of contamination using field screening techniques. Evidence of contamination was used to identify areas below the final excavation grade which had been impacted by the operation of the coal gasification plant. Samples collected from the excavation extents of hot spots and USTs show that it was unlikely that any contamination traveled from the post-1955 grade down to the pre-1955 grade. Additionally, the lack of benzene in the bottom of excavation samples suggests that a release from the coal gasification plant occurred below the redevelopment excavation final elevations of 20 to 16 feet. Qualitative data collected from borings for shoring elements and wells indicated that the spatial extent of the subsurface contaminant plume was different than initially estimated. Observations of spoils show that soil contamination extends further to the southwest and not as far to the east and north than originally estimated. Redefining the extent of the soil contamination beneath the property will allow further subsurface investigations to focus on collecting quantitative data in areas that still represent data gaps on the property, and passing over areas that have shown little signs of contamination. This information will help with the formation of a remediation plan should the need to clean up the site arise in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: Ao longo do tempo o Tratamento Endodôntico Não Cirúrgico tem sido das áreas da Medicina Dentária que mais tem evoluído. Todos os passos do tratamento têm sido revistos de forma a aumentar a taxa de sucesso. O controlo microbiológico é crucial para que o tratamento seja um sucesso a curto, médio e longo prazo. A assepsia deve ser mantida em todas as fases deste tratamento para que este seja um sucesso. Objetivo: Ao longo do meu percurso académico pude concluir que a fase da descontaminação dos cones, aquando a obturação (fase final do Tratamento Endodôntico Não Cirúrgico) era desvalorizada, o que me levou a efetuar uma revisão bibliográfica de modo a poder melhorar os meus conhecimentos e técnica. Material e Métodos: Para a elaboração deste trabalho foi realizada uma pesquisa bibliográfica recorrendo aos seguintes motores de busca: B-on, PubMed, Scielo e ScienceDirect, com as seguintes palavras-chave: “decontamination in endodontics”;” disinfection in endodontics”; “root canal irrigants”; “endodontics microbiology”; “Candida albicans“; “Enterococcus faecalis”; “sodium hypochlorite ”; “alcohol”; “contamination during Obturation”; “clorohexidine”; “filling materials endodontics”; “termoplastic gutta-percha”; “obturation material”; “Mineral Trioxide Aggregate”; “resilon”; “resin cement”; “resin material for root canal obturation”; “resin sealer”; “root canal”; “root canal sealing”; “root canal filling materials”; “condensation in endodontics”; “lateral condensation”; “gutta-percha”; “microlekeage”; “system B”; “fluid filtration model”;“dye penetration”. Como critério de inclusão estabeleceu-se que os artigos deveriam ser em Português, Inglês ou Espanhol e publicados entre 1995 e 2015. Dos resultados apresentados foram utilizados 110 artigos, pesquisados entre Maio de 2015 e 20 de Outubro de 2015. Foram ainda consultados livros de referência nestes mesmos locais. Conclusão: a presença de bactérias e os seus subprodutos no sistema tridimensional de canais está diretamente implicado com o insucesso do Tratamento Endodôntico. A descontaminação dos cones de guta-percha, é, portanto, um processo importante no Tratamento Endodôntico pois impede que os cones sejam colocados nos canais radiculares, estando contaminados por microorganismos que inviabilizam o tratamento efetuado. A submersão dos cones durante um minuto em clorohexidina a 2% ou hipoclorito a 5,25% está indicado e comprovado como um processo eficiente de desinfeção dos cones.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. The aim was to compare the percentage and depth of sealer penetration into dentinal tubules during obturation using Sealer 26, GuttaFlow, or Sealapex in root canals filled with the lateral compaction technique. Study design. Thirty root canals filled with the lateral compaction technique using GuttaFlow (n = 10), Sealapex (n = 10), or Sealer 26 (n = 10) were analyzed using confocal microscopy. The teeth were sectioned at 3 and 5 mm from the apex, and statistical analyses was performed using analysis of variance-Tukey test (P < .05). Results. Sealapex showed the deepest sealer penetration at both levels evaluated (P < .05). No statistically significance was found between Sealer 26 and GuttaFlow at the 3 mm and 5 mm levels. No statistical significance was found in the percentage of penetration around the root canal wall among the 3 sealers evaluated at both levels. Conclusions. Although Sealapex displayed deeper penetration into the dentinal tubules there was no difference in the percentage of adaptation to the root canal walls among the 3 sealers evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 450-457)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Prosthetic restorations that have been tried in the patient's mouth are potential sources of infection. In order to avoid cross-infection, protocols for infection control should be established in dental office and laboratory. This study evaluated the antimicrobial efficacy of disinfectants on full metal crowns contaminated with microorganisms. Full crowns cast in a Ni-Cr alloy were assigned to one control group (n=6) and 5 experimental groups (n=18). The crowns were placed in flat-bottom glass balloons and were autoclaved. A microbial suspension of each type of strain - S. aureus, P. aeruginosa, S. mutans, E. faecalis and C. albicans- was aseptically added to each experimental group, the crowns being allowed for contamination during 30 min. The contaminated specimens were placed into recipients with the chemical disinfectants (1% and 2% sodium hypochlorite and 2% glutaraldehyde) for 5, 10 and 15 min. Thereafter, the crowns were placed into tubes containing different broths and incubated at 35ºC. The control specimens were contaminated, immersed in distilled water for 20 min and cultured in Thioglycollate broth at 35ºC. Microbial growth assay was performed by qualitative visual examination after 48 h, 7 and 12 days. Microbial growth was noticed only in the control group. In the experimental groups, turbidity of the broths was not observed, regardless of the strains and immersion intervals, thus indicating absence of microbial growth. In conclusion, all chemical disinfectants were effective in preventing microbial growth onto full metal crowns.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Studies on microbial characterization of cold-smoked salmon and salmon trout during cold storage were performed on samples available in the Portuguese market. Samples were also classified microbiologically according to guidelines for ready-to-eat (RTE) products. Further investigations on sample variability and microbial abilities to produce tyramine and histamine were also performed. The coefficient of variation for viable counts of different groups of microorganisms of samples collected at retail market point was high in the first 2 wk of storage, mainly in the Enterobacteriaceae group and aerobic plate count (APC), suggesting that microbiological characteristics of samples were different in numbers, even within the same batch from the same producer. This variation seemed to be decreased when storage and temperature were controlled under lab conditions. The numbers of Enterobacteriaceae were influenced by storage temperature, as indicated by low microbial numbers in samples from controlled refrigeration. Lactic acid bacteria (LAB) and Enterobacteriaceae were predominant in commercial products, a significant percentage of which were tyramine and less histamine producers. These results might be influenced by (1) the technological processes in the early stages of production, (2) contamination during the smoking process, and (3) conditions and temperature fluctuations during cold storage at retail market point of sale.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective Biomonitoring of solvents using the unchanged substance in urine as exposure indicator is still relatively scarce due to some discrepancies between the results reported in the literature. Based on the assessment of toluene exposure, the aim of this work was to evaluate the effects of some steps likely to bias the results and to measure urinary toluene both in volunteers experimentally exposed and in workers of rotogravure factories. Methods Static headspace was used for toluene analysis. o-Cresol was also measured for comparison. Urine collection, storage and conservation conditions were studied to evaluate possible loss or contamination of toluene in controlled situations applied to six volunteers in an exposure chamber according to four scenarios with exposure at stable levels from 10 to 50 ppm. Kinetics of elimination of toluene were determined over 24 h. A field study was then carried out in a total of 29 workers from two rotogravure printing facilities. Results Potential contamination during urine collection in the field is confirmed to be a real problem but technical precautions for sampling, storage and analysis can be easily followed to control the situation. In the volunteers at rest, urinary toluene showed a rapid increase after 2 h with a steady level after about 3 h. At 47.1 ppm the mean cumulated excretion was about 0.005% of the amount of the toluene ventilated. Correlation between the toluene levels in air and in end of exposure urinary sample was excellent (r = 0.965). In the field study, the median personal exposure to toluene was 32 ppm (range 3.6-148). According to the correlations between environmental and biological monitoring data, the post-shift urinary toluene (r = 0.921) and o-cresol (r = 0.873) concentrations were, respectively, 75.6 mu g/l and 0.76 mg/g creatinine for 50 ppm toluene personal exposure. The corresponding urinary toluene concentration before the next shift was 11 mu g/l (r = 0.883). Conclusion Urinary toluene was shown once more time a very interesting surrogate to o-cresol and could be recommended as a biomarker of choice for solvent exposure. [Authors]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35°C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 µg/ml, Isoniazid - 0.2 µg/ml, Pyrazinamide - 100 µg/ml, Ethambutol - 2.5 µg/ml, Ethionamide - 1.25 µg/ml, and Streptomycin - 2 µg/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We studied the ectoparasitic bat flies of three phyllostomid vampire bat species. Bats were collected monthly from April 2004-March 2005 in caves within the Cafuringa Environmental Protection Area in the Federal District of Brazil. A total of 1,259 specimens from six species in the Streblidae family were collected from 332 bats. High host affinity from the sampled bat fly species and high prevalence of bat flies confirms the primary fly-host associations (Strebla wiedemanni, Trichobius parasiticus and Trichobius furmani with Desmodus, Trichobius diaemi and Strebla diaemi with Diaemus and T. furmani with Diphylla). Male flies outnumbered females in several associations. Some of the observed associations (e.g., Strebla mirabilis with Desmodus and S. mirabilis, Trichobius uniformis and S. wiedemanni with Diphylla) were inconclusive and the causes of the associations were unclear. There are several explanations for these associations, including (i) accidental contamination during sampling, (ii) simultaneous capture of several host species in the same net or (iii) genuine, but rare, ecological associations. Although various species of vampire bats share roosts, have similar feeding habits and are close phylogenetic relatives, they generally do not share ectoparasitic streblid bat flies. T. diaemi and S. diaemi associations with Diaemus youngi have not been previously reported in this region.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To investigate the dual-energy CT behavior of cocaine and heroin and of typical adulterants, and to evaluate the elemental composition of pure cocaine and heroin compared with cocaine and heroin in bodypacks. METHODS: Pure heroin and pure synthetic cocaine samples, eight different adulterants, and in each case ten different bodypacks containing cocaine or heroin, were imaged at 80, 100, 120, and 140 kVp in a dual source CT system at two different degrees of compression. Two radiologists, blinded to the samples, measured the attenuation. The dual-energy index (DEI) was calculated. We performed atomic mass spectrometry for the elemental analysis of pure cocaine, pure heroin, and heroin and cocaine in bodypacks, and 140 kVp in a dual-source CT system. RESULTS: Inter- and intra-observer agreement for attenuation measurements was good (r = 0.61-0.72; p < 0.01). The cocaine bodypacks had a positive DEI of 0.029, while the pure drugs and the heroin bodypacks had a negative DEI (-0.051 to -0.027). Levamisole was the only substance which expressed a positive DEI of 0.011, while the remaining adulterants had negative DEIs ranging between -0.015 and -0.215. Atomic mass spectrometry revealed a concentration of tin in the cocaine bodypack that was 67 times higher than in the pure synthetic cocaine sample. CONCLUSIONS: The different DEIs of bodypacks containing cocaine and heroin allow them to be distinguished with dual-energy CT. Although the material properties of pure cocaine, pure heroin, or common drug extenders do not explain the differences in DEI, tin contamination during illicit natural cocaine production may be a possible explanation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although prosthetic joint infection (PJI) is a rare event after arthroplasty, it represents a significant complication that is associated with high morbidity, need for complex treatment, and substantial healthcare costs. An accurate and rapid diagnosis of PJI is crucial for treatment success. Current diagnostic methods in PJI are insufficient with 10-30% false-negative cultures. Consequently, there is a need for research and development into new methods aimed at improving diagnostic accuracy and speed of detection. In this article, we review available conventional diagnostic methods for the diagnosis of PJI (laboratory markers, histopathology, synovial fluid and periprosthetic tissue cultures), new diagnostic methods (sonication of implants, specific and multiplex PCR, mass spectrometry) and innovative techniques under development (new laboratory markers, microcalorimetry, electrical method, reverse transcription [RT]-PCR, fluorescence in situ hybridization [FISH], biofilm microscopy, microarray identification, and serological tests). The results of highly sensitive diagnostic techniques with unknown specificity should be interpreted with caution. The organism identified by a new method may represent a real pathogen that was unrecognized by conventional diagnostic methods or contamination during specimen sampling, transportation, or processing. For accurate interpretation, additional studies are needed, which would evaluate the long-term outcome (usually >2 years) with or without antimicrobial treatment. It is expected that new rapid, accurate, and fully automatic diagnostic tests will be developed soon.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Probably one of the most difficult and challenging aspects of measuring trace metals in natural waters is to avoid contamination during sampling, manipulation and analysis. This work discusses how to avoid contamination using simple procedures, and considers alternative methods to purify deionised water and low grade reagents to enable accurate determination of trace metals in natural waters in a common laboratory. Measurements were performed by cathodic stripping voltammetry and copper was used as a model metal to test the procedures. It was possible to evaluate copper speciation in natural waters even when total dissolved copper concentration was as low as 1.5 nmol L-1. The methods' accuracy was confirmed by analysis of certified seawater.