990 resultados para Constant pressure sprayer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The micro-scale abrasive wear test by rotative ball has gained large acceptance in universities and research centers, being widely used in studies on the abrasive wear of materials. Two wear modes are usually observed in this type of test: ""rolling abrasion"" results when the abrasive particles roll on the surface of the tested specimen, while ""grooving abrasion"" is observed when the abrasive particles slide; the type of wear mode has a significant effect on the overall behaviour of a tribological system. Several works on the friction coefficient during abrasive wear tests are available in the literature, but only a few were dedicated to the friction coefficient in micro-abrasive wear tests conducted with rotating ball. Additionally, recent works have identified that results may also be affected by the change in contact pressure that occurs when tests are conducted with constant applied force. Thus, the purpose of this work is to study the relationship between friction coefficient and abrasive wear modes in ball-cratering wear tests conducted at ""constant normal force"" and ""constant pressure"". Micro-scale abrasive wear tests were conducted with a ball of AISI52100 steel and a specimen of AISIH10 tool steel. The abrasive slurry was prepared with black silicon carbide (SiC) particles (average particle size of 3 mu m) and distilled water. Two constant normal force values and two constant pressure values were selected for the tests. The tangential and normal loads were monitored throughout the tests and their ratio was calculated to provide an indication of the friction coefficient. In all cases, optical microscopy analysis of the worn craters revelated only the presence of grooving abrasion. However, a more detailed analysis conducted by SEM has indicated that different degrees of rolling abrasion have also occurred along the grooves. The results have also shown that: (i) for the selected values of constant normal force and constant pressure, the friction coefficient presents, approximately, the same range of values and (ii) loading conditions play an important role on the occurrence of rolling abrasion or grooving abrasion and, consequently, on the average value and scatter of the friction coefficient in micro-abrasive wear tests. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several machining processes have been created and improved in order to achieve the best results ever accomplished in hard and difficult to machine materials. Some of these abrasive manufacturing processes emerging on the science frontier can be defined as ultra-precision grinding. For finishing flat surfaces, researchers have been putting together the main advantages of traditional abrasive processes such as face grinding with constant pressure, fixed abrasives for two-body removal mechanism, total contact of the part with the tool, and lapping kinematics as well as some specific operations to keep grinding wheel sharpness and form. In the present work, both U d-lap grinding process and its machine tool were studied aiming nanometric finishing on flat metallic surfaces. Such hypothesis was investigated on AISI 420 stainless steel workpieces U d-lap ground with different values of overlap factor on dressing (Ud=1, 3, and 5) and grit sizes of conventional grinding wheels (silicon carbide (SiC)=#800, #600, and #300) applying a new machine tool especially designed and built for such finishing. The best results, obtained after 10 min of machining, were average surface roughness (Ra) of 1.92 nm, 1.19-μm flatness deviation of 25.4-mm-diameter workpieces, and mirrored surface finishing. Given the surface quality achieved, the U d-lap grinding process can be included among the ultra-precision abrasive processes and, depending on the application, the chaining steps of grinding, lapping, and polishing can be replaced by the proposed abrasive process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical Reaction Engineering. Course 2011-12. Solution of problem 2: constant pressure adiabatic stirred batch reactor with variable heat capacities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Durante a fase de desenvolvimento de novos produtos fitossanitários é comumente utilizado o pulverizador a pressão constante, pressurizado com CO2. O gás carbônico pode provocar a acidificação da água e afetar o comportamento do composto que está sendo avaliado. No presente trabalho, amostras de água de 30 diferentes fontes foram pressurizadas com CO2 durante cinco minutos, até 275 kPa (40 lbf/pol.2), e o pH foi medido na água que saiu do bico e na água no inteior do tanque do pulverizador. Os resultados mostraram redução nos valores do pH em toda as amostras . Os valores do pH elevaram-se ligeiramente após a saída da água pelo bico do pulverizador. A redução, em alguns casos, foi marcante, atingindo 4,91 unidades de pH no caso mais drástico. Esses dados levam a recomendar cautela na interpretação dos resultados obtidos com o uso dos pulverizadores pressurizados com o gás carbônico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paperaims to determine the velocity profile, in transient state, for a parallel incompressible flow known as Couette flow. The Navier-Stokes equations were applied upon this flow. Analytical solutions, based in Fourier series and integral transforms, were obtained for the one-dimensional transient Couette flow, taking into account constant and time-dependent pressure gradients acting on the fluid since the same instant when the plate starts it´s movement. Taking advantage of the orthogonality and superposition properties solutions were foundfor both considered cases. Considering a time-dependent pressure gradient, it was found a general solution for the Couette flow for a particular time function. It was found that the solution for a time-dependent pressure gradient includes the solutions for a zero pressure gradient and for a constant pressure gradient.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: We aimed to compare plasma concentrations of carbon dioxide (CO(2)) in dogs that underwent intra- and preperitoneal CO(2) insufflation. Materials and Methods: Thirty dogs were studied. Ten formed a control group, 10 underwent intraperitoneal CO(2) insufflation, and 10 underwent preperitoneal CO(2) insufflation. General anesthesia with controlled ventilation was standardized for all dogs. After stabilizing the anesthesia, blood samples were collected at predetermined times and were sent for immediate gasometric analysis. Analysis of variance was used for comparing variables. Results: The plasma CO(2) concentration in the intraperitoneal insufflation group increased significantly more than in the preperitoneal insufflation group and was significantly greater than in the control group (P < 0.05). The pH values in the intraperitoneal group were lower than in the preperitoneal group (P < 0.05). Conclusion: The data from this study suggest that a greater plasma concentration of CO(2) is achieved by insufflation at constant pressure into the intraperitoneal space than into the preperitoneal space.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to assess the effectiveness of glyphosate, as Rodeo(r) formulation, to control Eichhornia crassipes, Pistia stratiotes, Salvinia molesta, Salvinia herzogii and Urochloa subquadripara, under greenhouse conditions. The doses assessed were (480, 960, 1440, 1920, 2400, 2880, 3360 and 3840 g ha-1 of glyphosate) with 0.5% of the Aterbane(r) BR surfactant and a control, with no herbicide application. All experiments were conducted in a completely randomized experimental design with ten replications. Applications were carried out by precision backpack sprayer at a CO2 constant pressure of 25 psi and spray solution consumption of 200 L ha-1. Product effectiveness was determined by assessing the growth inhibitions and phytotoxicity signals during the periods of 3, 7, 15, 21, 30 and 45 days after application (DAA). At 45 DAA, the highest glyphosate dose (3840 g ha-1) displayed 100% effectiveness for all four macrophyte species. Under greenhouse conditions, the glyphosate in formulation Rodeo(r) with 0.5% of Aterbarne(r) BR surfactant showed excellent effectiveness, inhibiting the growth of the floating aquatic macrophytes. This procedure can be included on the tillage plans for these species.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 µg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 µg/paw) and dipyrone (80-320 µg/paw) on carrageenin- (200 µg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 µg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Studies were conducted at Estacao Experimental de Citricultura de Bebedouro, SP to evaluate the response of glyphosate-resistant horseweed and hairy fleabane biotypes to herbicides glyphosate, bromacil + diuron, diuron e paraquat isolated and in mixture and effect of a sequential application of glyphosate. The experimental design was of complete randomized blocks with four replication and seven treatments. The herbicides were applied with costal sprayer, constant pressure with three nozzles TT110015, the equivalent spray volume was 150 L ha(-1). The control was visually evaluated, trough percentile note scale. The best results were obtained to general control of weed with diuron isolated and glyphosate in mixture with bromacil + diuron while to glyphosate-resistant horseweed and hairy fleabane there was no difference between the treatments. After sequential application to Conyza sp control, the best treatment was obtained associated with diuron and bromacil+diuron.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Apesar de possuir boa ação herbicida, alguns fatores afetam a eficácia do glifosato e, nesse contexto, realizaram-se estudos buscando formulações mais eficazes. O experimento foi instalado em área do Campus da FCAV-UNESP, Jaboticabal (SP). Testou-se a formulação potássica de glifosato comparada com solução aquosa e grânulos dispersíveis em água à mesma dosagem (0,36 kg.ha-1 e.a) em cinco intervalos (1, 2, 4, 6 e > 48 horas) sem chuva após a aplicação, comparados com uma testemunha sem uso de herbicidas. Foram aplicados em pós-emergência sobre Brachiaria plantaginea, B. decumbens e Digitaria horizontalis. A aplicação foi feita com pulverizador costal a CO2, à pressão de 2,5 kg.cm-2, munido de barra com seis bicos DG 110.02 e consumo de calda equivalente a 200 L.ha-1. Realizaram-se cinco avaliações de porcentagem de controle em relação à testemunha infestada, atribuídas visualmente, até 42 dias após aplicação. Notou-se que o controle da formulação potássica sobre as espécies avaliadas foi mais precoce, necessitando apenas quatro horas após sua aplicação para se igualar ao intervalo superior a 48 horas sem chuva. As demais necessitaram de, no mínimo, seis horas de intervalo.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Avaliou-se a eficácia do herbicida glifosato potássico, comparado ao sulfosato e ao glifosato amínico, utilizados como padrões comerciais. Os herbicidas foram aplicados em um pomar de laranja da variedade Pêra-rio, infestado por grama-seda (Cynodon dactylon) com aproximadamente 25 cm de altura, em 70% da área. O experimento foi instalado no município de Taiúva-SP, em solo Podzólico Vermelho-Amarelo, distrófico, de textura arenosa, com relevo suave ondulado. Os tratamentos testados foram: glifosato potássico (ZAPP Qi) a 1,05; 2,10 e 2,50 kg e.a./ha, sulfosato (ZAPP) e glifosato amínico (ROUNDUP CS) a 1,98 e 2,16 kg e.a./ha, respectivamente, além da testemunha sem capina. Os herbicidas foram aplicados em pós-emergência da planta daninha, com pulverizador costal, à pressão constante (mantida por CO2 comprimido) de 2,5 kg/cm², munido de barra com seis bicos de jato plano (leque) DG 11002, com um consumo de calda equivalente a 200 L/ha. Os melhores resultados de controle foram obtidos com 2,5 kg e.a./ha do glifosato potássico, que também garantiu menor brotação da grama-seda. No entanto, a dosagem de 2,10 kg e.a./ha deste mesmo herbicida não foi menos eficaz que o sulfosato e o glifosato, com 1,98 e 2,16 kg e.a./ha, respectivamente.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4K ≤ T ≤ 300K and hydrostatic pressure P ≤ 250MPa. Helium ( 4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1MPa (ambient pressure) and 104MPa on a single crystal of azurite, Cu 3(CO 3) 2(OH) 2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system. © 2012 American Institute of Physics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)