948 resultados para Cervical spine


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rheumatoid arthritis (RA) is a systemic chronic inflammatory disorder that can compromise the cervical spine in up to 80% of the cases. The most common radiological presentations of cervical involvement are atlantoaxial subluxation (AAS), cranial settling and subaxial subluxation (SAS). We performed a systematic review in the PubMed Database of articles published later 2005 to evaluate the prevalence, progression and risk factors for cervical spine involvement in RA patients. Articles were classified according to their level of evidence. Our literature review reported a wide range in the prevalence of cervical spine disease, probably explained by the different studied populations and disease characteristics. Uncontrolled RA is probably the main risk factor for developing a spinal instability. Adequate treatment with DMARD and BA can prevent development of cervical instabilities but did not avoid progression of a pre-existing injury. MRI is the best radiological method for diagnosis cervical spine involvement. AAS is the most common form of RA. Long term radiological follow-up is necessary to diagnosis patients with late instabilities and monitoring progression of diagnosed injuries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Manipulative therapy is frequently used in the management of musculoskeletal pain. A frequently reported clinical feature of this treatment is the immediacy with which it appears to initiate improvement in pain and function. A randomised, double blind, placebo controlled, repeated measures design was employed to study the initial effects of a cervical spine treatment technique in a group of 15 patients with lateral epicondylalgia. Pressure pain threshold, pain-free grip strength, upper limb neurodynamics, pain and function were assessed prior to and following application of either a treatment, placebo or control condition. All subjects received all three conditions. Differences between the pre-post measures were used as indicators of change in subject's symptom profiles. The treatment condition produced significant improvement in pressure pain threshold, pain-free grip strength, neurodynamics and pain scores relative to placebo and control conditions (P < 0.05). In summary, this study demonstrates that manipulative therapy is capable of eliciting a rapid hypoalgesic effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spinal involvement is a common presentation of multiple myeloma (MM); however, the cervical spine is the least common site of myelomatous involvement. Few studies evaluate the results of percutaneous vertebroplasty (PV) in the treatment of MM of the spine. The purpose of this series is to report on the use of PV in the treatment of MM of the cervical spine and to review the literature. From January 1994 to October 2007, four patients (three men and one woman; mean age, 45 years) who underwent five PV for painful MM in the cervical spine were retrospectively reviewed. The pain was estimated by the patient on a verbal analogic scale. Clinical follow-up was available for all patients (mean, 27.5 months; range, 1-96 months). The mean volume of cement injected per vertebral body was 2.3 +/- 0.8 mL (range, 1.0-4.0 mL) with a mean vertebral filling of 55.0 +/- 12.0% (range, 40.0-75.0%). Analgesic efficacy was achieved in all patients. One patient had a spinal instability due to a progression of spinal deformity noted on follow-up radiographs, without clinical symptoms. Cement leakage was detected in three (60%) of the five treated vertebrae. There was no clinical complication. The present series suggests that PV for MM of the cervical spine is safe and effective for pain control; nonetheless, the detrimental impact of the disease on bone quality should prompt close radiological follow-up after PV owing to the risk of spinal instability.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RAPPORT DE SYNTHÈSE : Chez les patients présentant une pathologie de la colonne cervicale, l'instrumentation des voies aériennes peut s'avérer délicate. En effet, l'impossibilité d'effectuer une extension de la nuque afin d'aligner correctement l'axe oro-pharyngo-trachéal, ainsi que l'ouverture de bouche limitée par la présence d'une minerve cervicale, rendent la laryngoscopie standard extrêmement difficile. Le but de cette étude est de démontrer que l'intubation oro-trachéale avec une minerve cervicale semi-rigide est possible à l'aide d'un vidéolaryngoscope récemment développé, le GlideScope®. Celui-ci est formé d'une lame courbe présentant une angulation accentuée à 60° à partir de son milieu, avec une petite caméra haute résolution et une source lumineuse enchâssées dans la partie inférieure au point d'inflexion. Différents travaux ont montré les avantages du GlideScope® par rapport à la lame de Macintosh standard "pour l'instrumentation des voies aériennes de routine ou en situation difficile. Après acceptation par la Commission d'Ethique, 50 patients, adultes consentants et programmés pour une intervention chirurgicale élective nécessitant une anesthésie générale ont été inclus dans cette étude. Malgré la présence d'une minerve cervicale semi-rigide Philadelphia® Patriot correctement positionnée et la tête fixée à la table d'opération, tous les patients ont pu être intubés a l'aide du GlideScope®. Aucune complication n'a été documentée pendant la procédure ou en post-opératoire. De plus, nous avons démontré que dans cette situation la visualisation des structures laryngées est significativement améliorée grâce au GlideScope®, par rapport à la lame de Macintosh utilisée lors de toute intubation standard. En conclusion, l'intubation oro-trachéale chez les patients ayant une minerve cervicale et la tête fixée est possible à l'aide du GlideScope®. La meilleure façon de sécuriser les voies aériennes chez les patients présentant une instabilité de la colonne cervicale est un sujet fortement débattu. L'utilisation du GlideScope® pourrait s'avérer une alternative intéressante, en particulier dans les situations d'urgence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot (R) cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope (R) and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack-Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients' tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43-61 s). The modified Cormack-Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi-rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions. METHODS Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact. RESULTS The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect. CONCLUSIONS Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In patients with cervical spine injury, a cervical collar may prevent cervical spine movements but renders tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesized that despite the presence of a semi-rigid cervical collar and with the patient's head taped to the trolley, we would be able to intubate all patients with the GlideScopeR and its dedicated stylet. Methods: 50 adult patients (ASA 1 or 2, BMI ≤35 kg/m2) scheduled for elective surgical procedures requiring tracheal intubation were included. After standardized induction of general anesthesia and neuromuscular blockade, the neck was immobilized with an appropriately sized semi-rigid Philadelphia Patriot® cervical collar, the head was taped to the trolley. Laryngoscopy was attempted using a Macintosh laryngoscope blade 4 and the modified Cormack Lehane grade was noted. Subsequently, laryngoscopy with the GlideScopeR was graded and followed by oro-tracheal intubation. Results: All patients were successfully intubated with the GlideScopeR and its dedicated stylet. The median intubation time was 50 sec [43; 61]. The modified Cormack Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScopeR (p <0.0001), reaching 2a in most of patients. Maximal mouth opening was significantly reduced with the cervical collar applied, 4.5 cm [4.5; 5.0] vs. 2.0 cm [1.8; 2.0] (p <0.0001). Conclusions: The GlideScope® allows oro-tracheal intubation in patients having their cervical spine immobilized by a semi-rigid collar and their head taped to the trolley. It furthermore decreases significantly the modified Cormack Lehane grade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To test the hypothesis that calcium pyrophosphate dihydrate (CPPD) deposition disease is a risk factor for neck pain. METHODS: A prevalent case-control study was conducted to assess cervical calcifications and neck pain between patients with and without known peripheral CPPD deposition disease. CPPD cases were included if diagnosed with CPPD deposition disease of peripheral joints, and excluded if their chief complaint was neck pain. Controls were randomly selected among consecutive patients, hospitalized for conditions unrelated to CPPD deposition disease or neck pain, and matched to CPPD cases by age and sex. Cervical calcifications were assessed by lateral cervical radiographs and computed tomography scans of the upper cervical spine; neck pain and cervical function were appraised by a validated questionnaire. RESULTS: Cervical calcifications were found in 24 out of 35 patients (69%) in the CPPD group compared to 4 out of 35 patients (11%) in the control group (p < 0.001). Patients with CPPD deposition disease reported significantly more neck pain and discomfort than controls (p < 0.001), and were 5 times more likely to report any neck pain (odds ratio 5.5; 95% confidence interval: 1.9, 21.9). Among male patients, more extensive cervical calcified deposits correlated with more severe neck pain (rs = 0.58, p = 0.03). CONCLUSION: These results suggest that CPPD deposition disease frequently involves the cervical spine and may be associated with the development of neck pain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spondylo-megaepiphyseal-metaphyseal dysplasia (SMMD; OMIM 613330) is a dysostosis/dysplasia caused by recessive mutations in the homeobox-containing gene, NKX3-2 (formerly known as BAPX1). Because of the rarity of the condition, its diagnostic features and natural course are not well known. We describe clinical and radiographic findings in six patients (five of which with homozygous mutations in the NKX3-2 gene) and highlight the unusual and severe changes in the cervical spine and the neurologic complications. In individuals with SMMD, the trunk and the neck are short, while the limbs, fingers and toes are disproportionately long. Radiographs show a severe ossification delay of the vertebral bodies with sagittal and coronal clefts, missing ossification of the pubic bones, large round "balloon-like" epiphyses of the long bones, and presence of multiple pseudoepiphyses at all metacarpals and phalanges. Reduced or absent ossification of the cervical vertebrae leads to cervical instability with anterior or posterior kinking of the cervical spine (swan neck-like deformity, kyknodysostosis). As a result of the cervical spine instability or deformation, five of six patients in our series suffered cervical cord injury that manifested clinically as limb spasticity. Although the number of individuals observed is small, the high incidence of cervical spine deformation in SMMD is unique among skeletal dysplasias. Early diagnosis of SMMD by recognition of the radiographic pattern might prevent of the neurologic complications via prophylactic cervical spine stabilization. © 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fibreoptic intubation remains a key technique for the management of difficult intubation. We randomly compared the second generation single-use Ambu(®) aScope? 2 videoscope with a standard re-usable flexible intubating fibrescope in 50 tracheal intubations in patients with a difficult airway simulated by a semirigid collar. All patients' tracheas were intubated successfully with the aScope 2 or the re-usable fibrescope. The median (IQR [range]) time to intubate was significantly longer with the aScope 2 70 (55-97 [41?-226]) s vs 50 (40-59 [27-175]) s, p = 0.0003) due to an increased time to see the carina. Quality of vision was significantly lower with the aScope 2 (excellent 24 (48%) vs 49 (98%), p = 0.0001; good 22 (44%) vs 1 (2%), p = 0.0001; poor 4 (8%) vs 0, p = 0.12) but with no difference in the subjective ease to intubate (easy score of 31 (62%) vs 38 (76%), p = 0.19; intermediate 12 (24%) vs 7 (14%), p = 0.31; difficult 7 (14%) vs 5 (5%), p = 0.76). The longer times to intubate and the poorer scores for quality of vision do not support the use of the single-use aScope 2 videoscope as an alternative to the re-usable fibrescope.