81 resultados para BALLOONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intra-aortic balloon pump (IABP) is the most frequently used mechanical circulatory support. Repeated trauma on the aortic wall has been reported as a cause of balloon perforation by endothelial denudation of atheromatous plaque. This study analyses the effect of IABP on the endothelium of the calf aorta. In 12 calves (mean weight: 72 +/- 6 kg) an IABP was inserted by femoral route and left during 6 hours on internal mode with a frequency of 80 cycles/min. The animals were sacrificed after the procedure (n = 4), at postoperative day (POD) 7 (n = 4), and at POD 14 (n = 4). In the aorta facing the balloon, nine transmural samples were taken proximally (n = 3), at mid height (n = 3) and distally (n = 3), for histological analysis of the percentage of aortic surface covered with endothelium. The percentage of aortic surface covered with endothelium at POD 0, 7 and 14 was proximally: 72.5 +/- 27.5%, 83.7 +/- 16.9% and 93.3 +/- 8.9% respectively; at mid-height: 50.8 +/- 30.7%, 65 +/- 25% and 95 +/- 5%; and distally: 31.4 +/- 20.1%, 48.3 +/- 34.4% and 85 +/- 10%. A large portion of the aortic endothelium is abraded after 6 hours of IAB pumping. This effect is more important at the distal level of the aorta. After two weeks, most of the endothelium has regenerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ever since the first percutaneous transluminal angioplasty (PTA) was carried out in Switzerland in 1977, restenosis remains a major drawback of this minimally invasive treatment intervention. Numerous attempts to increase vessel patency after PTA have included systemic medications and endovascular brachytherapy, but these techniques have not met our expectations in preventing restenosis. Nitinol stents have been shown to reduce rates of restenosis and target lesion revascularization in patients undergoing endovascular treatment of long femoropopliteal obstructions. Despite further technical refinements in nitinol stent technology, restenosis occurs in approximately every third patient undergoing femoropopliteal stenting. Similarly, initial clinical trials with drug-eluting stents have failed to indicate restenosis inhibition in femoropopliteal segment. Unfortunately, restenosis rates after below-the-knee PTA and stenting have been reported to be even higher than those following femoropopliteal revascularization. Current concepts for the prevention and treatment of restenosis after PTA or stenting include the sustained release of antiproliferative paclitaxel into the vessel wall. Drug eluting balloons are a promising, novel technology aimed at inhibiting restenosis after PTA. Its clinical efficacy in reducing restenosis has already been proven for coronary arteries as well as for the femoropopliteal segment. The purpose of this article is to review the clinical utility of drug-eluting balloons for lower limb endovascular interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug-coated balloons (DCB) are being increasingly used in interventional cardiology and are established for the treatment of in-stent restenosis (ISR). It is unclear how effective they are in patients with de novo lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To explore the cost-effectiveness of using drug-eluting balloon (DEB) angioplasty for the treatment of femoropopliteal arterial lesions, which has been shown to significantly lower the rates of target lesion revascularization (TLR) compared with standard balloon angioplasty (BA). METHODS A simplified decision-analytic model based on TLR rates reported in the literature was applied to baseline and follow-up costs associated with in-hospital patient treatment during 1 year of follow-up. Costs were expressed in Swiss Francs (sFr) and calculated per 100 patients treated. Budgets were analyzed in the context of current SwissDRG reimbursement figures and calculated from two different perspectives: a general budget on total treatment costs (third-party healthcare payer) as well as a budget focusing on the physician/facility provider perspective. RESULTS After 1 year, use of DEB was associated with substantially lower total inpatient treatment costs when compared with BA (sFr 861,916 vs. sFr 951,877) despite the need for a greater investment at baseline related to higher prices for DEBs. In the absence of dedicated reimbursement incentives, however, use of DEB was shown to be the financially less favorable treatment approach from the physician/facility provider perspective (12-month total earnings: sFr 179,238 vs. sFr 333,678). CONCLUSION Use of DEBs may be cost-effective through prevention of TLR at 1 year of follow-up. The introduction of dedicated financial incentives aimed at improving DEB reimbursements may help lower total healthcare costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bibliographical references included in "Notes" (p. 45-47)

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The real-time optimization of large-scale systems is a difficult problem due to the need for complex models involving uncertain parameters and the high computational cost of solving such problems by a decentralized approach. Extremum-seeking control (ESC) is a model-free real-time optimization technique which can estimate unknown parameters and can optimize nonlinear time-varying systems using only a measurement of the cost function to be minimized. In this thesis, we develop a distributed version of extremum-seeking control which allows large-scale systems to be optimized without models and with minimal computing power. First, we develop a continuous-time distributed extremum-seeking controller. It has three main components: consensus, parameter estimation, and optimization. The consensus provides each local controller with an estimate of the cost to be minimized, allowing them to coordinate their actions. Using this cost estimate, parameters for a local input-output model are estimated, and the cost is minimized by following a gradient descent based on the estimate of the gradient. Next, a similar distributed extremum-seeking controller is developed in discrete-time. Finally, we consider an interesting application of distributed ESC: formation control of high-altitude balloons for high-speed wireless internet. These balloons must be steered into a favourable formation where they are spread out over the Earth and provide coverage to the entire planet. Distributed ESC is applied to this problem, and is shown to be effective for a system of 1200 ballons subjected to realistic wind currents. The approach does not require a wind model and uses a cost function based on a Voronoi partition of the sphere. Distributed ESC is able to steer balloons from a few initial launch sites into a formation which provides coverage to the entire Earth and can maintain a similar formation as the balloons move with the wind around the Earth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of subglottic stenosis in children remains a challenge for the otolaryngologist and may involve procedures such as endoscopy, open surgery, and often both. In the recent past, high-pressure balloons have been used in endoscopic treatment due to their relative facility and high success rates. To report success rates in the treatment of acquired subglottic stenosis with balloon laryngoplasty in children and identify predictive factors for the success of the technique and its complications. Descriptive, prospective study of children who were diagnosed with acquired subglottic stenosis and underwent balloon laryngoplasty as the primary treatment. Balloon laryngoplasty was performed in 48 children with an average age of 20.7 months: 31 presented with chronic subglottic stenosis and 17 with acute stenosis. Success rate was 100% for acute and 39% for chronic subglottic stenosis. Success was significantly associated with several factors, including recently acquired stenosis, initial grade of stenosis, younger patient age, and the absence of tracheotomy. Complications were transitory dysphagia observed in three children and a submucosal cyst in one of the patients. Balloon laryngoplasty may be considered as a first line of treatment for acquired subglottic stenosis. In acute cases, the success rate was 100%, and even though results are less promising in chronic cases, complications were not significant and the patients can undergo open surgery without contraindications. Predictive factors of success were acute stenosis, less severe grades of stenosis, younger patient age, and the absence of tracheotomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prosthetic restorations that have been tried in the patient's mouth are potential sources of infection. In order to avoid cross-infection, protocols for infection control should be established in dental office and laboratory. This study evaluated the antimicrobial efficacy of disinfectants on full metal crowns contaminated with microorganisms. Full crowns cast in a Ni-Cr alloy were assigned to one control group (n=6) and 5 experimental groups (n=18). The crowns were placed in flat-bottom glass balloons and were autoclaved. A microbial suspension of each type of strain - S. aureus, P. aeruginosa, S. mutans, E. faecalis and C. albicans- was aseptically added to each experimental group, the crowns being allowed for contamination during 30 min. The contaminated specimens were placed into recipients with the chemical disinfectants (1% and 2% sodium hypochlorite and 2% glutaraldehyde) for 5, 10 and 15 min. Thereafter, the crowns were placed into tubes containing different broths and incubated at 35ºC. The control specimens were contaminated, immersed in distilled water for 20 min and cultured in Thioglycollate broth at 35ºC. Microbial growth assay was performed by qualitative visual examination after 48 h, 7 and 12 days. Microbial growth was noticed only in the control group. In the experimental groups, turbidity of the broths was not observed, regardless of the strains and immersion intervals, thus indicating absence of microbial growth. In conclusion, all chemical disinfectants were effective in preventing microbial growth onto full metal crowns.