995 resultados para Atomic absortion spectroscopy
Resumo:
The adhesion force between an atomic force microscope (AFM) tip and sample surfaces, mica and quartz substrates, was measured in air and water. The force curves show that the adhesion has a strong dependence on both the surface roughness and the environmental conditions surrounding the sample. The variability of the adhesion force was examined in a series of measurements taken at the same point, as well as at different places on the sample surface. The adhesion maps obtained from the distribution of the measured forces indicated regions contaminated by either organic compounds or adsorbed water. Using simple mathematical expressions we could quantitatively predict the adhesion force behavior in both air and water. The experimental results are in good agreement with theoretical calculations, where the adhesion forces in air and water were mostly associated with capillary and van der Waals forces, respectively. A small long-range repulsive force is also observed in water due to the overlapping electrical double-layers formed on both the tip and sample surfaces.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
L’objectiu d’aquest projecte fi de carrera és en primer lloc, determinar les modificacions a realitzar en el laboratori de lubricants i combustibles de l’EPS per a la utilització de l’espectrofotòmetre d’absorció atòmica de flama; en segon lloc, posar a punt l’aparell establint els paràmetres i les condicions d’assaig idònies per a portar a terme les anàlisis de metalls de desgast presents en olis lubricants usats de motors de combustió interna. I finalment, establir un protocol de treball al laboratori i estudiar la viabilitat d’oferir el servei d’anàlisi de lubricants a empreses i particulars
Resumo:
L’objectiu d’aquest projecte fi de carrera és en primer lloc, determinar les modificacions a realitzar en el laboratori de lubricants i combustibles de l’EPS per a la utilització de l’espectrofotòmetre d’absorció atòmica de flama; en segon lloc, posar a punt l’aparell establint els paràmetres i les condicions d’assaig idònies per a portar a terme les anàlisis de metalls de desgast presents en olis lubricants usats de motors de combustió interna. I finalment, establir un protocol de treball al laboratori i estudiar la viabilitat d’oferir el servei d’anàlisi de lubricants a empreses i particulars
Resumo:
Markets are increasingly competitive and the companies feel the urge to improve their manufacturing processes. Blending that with a larger control of quality and safety it was created a need to develop new methods of analysis each time more accurate, faster and with lower costs. Alentejo is a region with a wide variety of soils, most of them are rich in calcium and potassium. In the production of sparkling wine many wineries use encapsulated yeast in alginate beads, instead of the traditional method, champenoise. The first method is faster, allowing a more versatile production, reducing the risk of contamination and features organoleptic characteristics similar to the traditional method (yeast free). However, encapsulated yeast spheres should be only used if the base wine matches a number of features, among them calcium content. In this study the calcium content in the wine was determined by atomic absorption spectroscopy (AAS) and by near-infrared spectroscopy. The AAS is a high sensitivity method clearly produces a reliable result, however it is very time consuming and produces great quantities of environmental waste, therefore the possibility of using near-infrared spectroscopy as a method was studied to be a fast, simple and clean alternative to the AAS. It was obtained a calibration model with a variation coefficient higher than 0.80 which indicates that the near-infrared spectroscopy as an adequately alternative the ASS.
Resumo:
In this study, a procedure is developed for cloud point extraction of Pd(II) and Rh(III) ions in aqueous solution using Span 80 (non-ionic surfactant) prior to their determination by flame atomic absorption spectroscopy. This method is based on the extraction of Pd(II) and Rh(III) ions at a pH of 10 using Span 80 with no chelating agent. We investigated the effect of various parameters on the recovery of the analyte ions, including pH, equilibration temperature and time, concentration of Span 80, and ionic strength. Under the best experimental conditions, the limits of detection based on 3Sb for Pd(II) and Rh(III) ions were 1.3 and 1.2 ng mL-1, respectively. Seven replicate determinations of a mixture of 0.5 µg mL-1 palladium and rhodium ions gave a mean absorbance of 0.058 and 0.053 with relative standard deviations of 1.8 and 1.6%, respectively. The developed method was successfully applied to the extraction and determination of the palladium and rhodium ions in road dust and standard samples and satisfactory results were obtained.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)