963 resultados para Active Filter


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Characteristics of tunable wavelength pi'n/pin filters based on a-SiC:H multilayered stacked cells are studied both experimentally and theoretically. Results show that the device combines the demultiplexing operation with the simultaneous photodetection and self amplification of the signal. An algorithm to decode the multiplex signal is established. A capacitive active band-pass filter model is presented and supported by an electrical simulation of the state variable filter circuit. Experimental and simulated results show that the device acts as a state variable filter. It combines the properties of active high-pass and low-pass filter sections into a capacitive active band-pass filter using a changing capacitance to control the power delivered to the load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This letter presents a novel recursive active filter topology that provides dual-band performance, with independent tuning capability in both bands. The dual-band operation is achieved by using two independent feedback lines. Additionally, linear phase shifters based on left-handed cells are included in these two branches in order to tune the center frequency of both pass bands.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Characteristics of tunable wavelength filters based on a-SiC:H multi-layered stacked cells are studied both theoretically and experimentally. Results show that the light-activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal. The sensor is a bias wavelength current-controlled device that make use of changes in the wavelength of the background to control the power delivered to the load, acting a photonic active filter. Its gain depends on the background wavelength that controls the electrical field profile across the device.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An oscillating overvoltage has become a common phenomenon at the motor terminal in inverter-fed variable-speed drives. The problem has emerged since modern insulated gate bipolar transistors have become the standard choice as the power switch component in lowvoltage frequency converter drives. Theovervoltage phenomenon is a consequence of the pulse shape of inverter output voltage and impedance mismatches between the inverter, motor cable, and motor. The overvoltages are harmful to the electric motor, and may cause, for instance, insulation failure in the motor. Several methods have been developed to mitigate the problem. However, most of them are based on filtering with lossy passive components, the drawbacks of which are typically their cost and size. In this doctoral dissertation, application of a new active du/dt filtering method based on a low-loss LC circuit and active control to eliminate the motor overvoltages is discussed. The main benefits of the method are the controllability of the output voltage du/dt within certain limits, considerably smaller inductances in the filter circuit resulting in a smaller physical component size, and excellent filtering performance when compared with typical traditional du/dt filtering solutions. Moreover, no additional components are required, since the active control of the filter circuit takes place in the process of the upper-level PWM modulation using the same power switches as the inverter output stage. Further, the active du/dt method will benefit from the development of semiconductor power switch modules, as new technologies and materials emerge, because the method requires additional switching in the output stage of the inverter and generation of narrow voltage pulses. Since additional switching is required in the output stage, additional losses are generated in the inverter as a result of the application of the method. Considerations on the application of the active du/dt filtering method in electric drives are presented together with experimental data in order to verify the potential of the method.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

WDM multilayered SiC/Si devices based on a-Si:H and a-SiC:H filter design are approached from a reconfigurable point of view. Results show that the devices, under appropriated optical bias, act as reconfigurable active filters that allow optical switching and optoelectronic logic functions development. Under front violet irradiation the magnitude of the red and green channels are amplified and the blue and violet reduced. Violet back irradiation cuts the red channel, slightly influences the magnitude of the green and blue ones and strongly amplifies de violet channel. This nonlinearity provides the possibility for selective removal of useless wavelengths. Particular attention is given to the amplification coefficient weights, which allow taking into account the wavelength background effects when a band needs to be filtered from a wider range of mixed signals, or when optical active filter gates are used to select and filter input signals to specific output ports in WDM communication systems. A truth table of an encoder that performs 8-to-1 multiplexer (MUX) function is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Multilayered heterostructures based on embedded a-Si:H and a-SiC:H p-i-n filters are analyzed from differential voltage design perspective using short- and long-pass filters. The transfer functions characteristics are presented. A numerical simulation is presented to explain the filtering properties of the photonic devices. Several monochromatic pulsed lights, separately (input channels) or in a polychromatic mixture (multiplexed signal) at different bit rates, illuminated the device. Steady-state optical bias is superimposed from the front and the back side. Results show that depending on the wavelength of the external background and impinging side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. Particular attention is given to the amplification coefficient weights, which allow to take into account the wavelength background effects when a band or frequency needs to be filtered or the gate switch, in which optical active filter gates are used to select and filter input signals to specific output ports in wavelength division multiplexing (WDM) communication systems. This nonlinearity provides the possibility for selective removal or addition of wavelengths. A truth table of an encoder that performs 8-to-1 MUX function exemplifies the optoelectronic conversion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the experimental implementation of a shunt active power filter applied to a three-phase induction generator. The control strategy of active filter turned to the excitation control of the machine and to decrease the harmonics in the generator output current. Involved the implementation of a digital PWM switching, and was made a comparison of two techniques for obtaining the reference currents. The first technique is based on the synchronous dq reference method and the second on the theory of instantaneous power. The comparison is performed via simulation and experimental results. To obtain the experimental results, was mounted a bench trial and the control and communications needed were implemented using DSP - MS320F2812. The simulation results and experimental data proved the efficiency of the filter to apply, highlighting the technique of instantaneous power

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a novel and simple positive sequence detector (PSD), which is inherently self-adjustable to fundamental frequency deviations by means of a software-based PLL (Phase Locked Loop). Since the proposed positive sequence detector is not based on Fortescue's classical decomposition and no special input filtering is needed, its dynamic response may be as fast as one fundamental cycle. The digital PLL ensures that the positive sequence components can be calculated even under distorted waveform conditions and fundamental frequency deviations. For the purpose of validating the proposed models, the positive sequence detector has been implemented in a PC-based Power Quality Monitor and experimental results illustrate its good performance. The PSD algorithm has also been evaluated in the control loop of a Series Active Filter and simulation results demonstrate its effectiveness in a closed-loop system. Moreover, considering single-phase applications, this paper also proposes a general single-phase PLL and a Fundamental Wave Detector (FWD) immune to frequency variations and waveform distortions. © 2005 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents possible selective current compensation strategies based on the Conservative Power Theory (CPT). This recently proposed theory, introduces the concept of complex power conservation under non-sinusoidal conditions. Moreover, the related current decompositions results in several current terms, which are associated with a specific physical phenomena (power absorption P, energy storage Q, voltage and current distortion D). Such current components are used in this work for the definition of different current compensators, which can be selective in terms of minimizing particular disturbing effects. The choice of one or other current component for compensation directly affects the sizing and cost of active and/or passive devices and it will be demonstrated that it can be done to attend predefined limits for harmonic distortion, unbalances and/or power factor. Single and three-phase compensation strategies will be discussed by means of the CPT Framework. Simulation and experimental results will be demonstrated in order to validate their performance. © 2009 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’obiettivo di tesi consiste nel valutare il funzionamento di regolatori ripetitivi per il controllo di un inverter utilizzato come filtro attivo al fine di eliminare le armoniche di corrente prodotte da un carico distorcente trifase connesso in rete. È descritto lo schema di simulazione realizzato in ambiente Simulink di Matlab per poter individuare una possibile implementazione del controllo. È descritta l’attività di prototipazione rapida svolta mediante il sistema dSPACE per poter verificare sperimentalmente il funzionamento del controllo con regolatore ripetitivo su un modello di impianto reale costituito da inverter, carico distorcente e rete.