970 resultados para Acidification wet bulb
Resumo:
The close relationship between rain and lightning is well known. However, there are numerous documented observations of heavy rain accompanied by little or no lightning activity (Williams et al, 1992; Jayaratne, 1993). Kuleshov et al (2002) studied thunderstorm distribution and frequency in Australia and concluded that thunderstorm frequency (as expressed by number of thunder-days) in Australia does not, in general, appear to vary in any consistent way with rainfall. However, thunder-days describe occurrence of thunderstorms as heard by an observer, and therefore could be only proxy data to evaluate actual lightning activity (i.e. number of total or cloud-to-ground flashes). Field experiments have demonstrated a strong increase in lightning activity with convective available potential energy (CAPE). It has also been shown that CAPE increases linearly with potential wet bulb temperature, Tw (Williams et al, 1992). In this study, we examine the relationship between lightning ground flash incidence and the two parameters – surface rainfall and surface wet bulb maximum temperature for selected localities around Australia...
Resumo:
On cover: Reduction of Greenwich meteorological observations. pt. II. Barometer, 1874-1876, & thermometers, 1869-1876
Resumo:
O uso da irrigação em cafeeiro é uma tecnologia que vem se consolidando e mostrando-se economicamente viável ao longo dos tempos, trazendo junto com ela a técnica da fertirrigação. Desta forma, o presente estudo teve como objetivo avaliar a influência de formas de aplicação e fontes de fertilizantes sobre a condutividade elétrica e pH da solução do solo, bem como no desenvolvimento e produção do café conilon irrigado por gotejamento. O trabalho foi desenvolvido em São Gabriel da Palha, Espírito Santo, utilizando o clone 12V da variedade INCAPER 8142. O experimento foi delineado em blocos ao acaso (DBC) com seis tratamentos e quatro blocos. Os tratamentos adotados foram: T1 - Controle - adubação nitrogenada e potássica aplicada via solo nas fontes ureia e cloreto de potássio; T2 - Adubação nitrogenada e potássica aplicada via solo nas fontes ureia e cloreto de potássio de liberação controlada; T3 - Adubação nitrogenada e potássica aplicada via fertirrigação nas fontes ureia e cloreto de potássio; T4 - Adubação nitrogenada e potássica aplicada via fertirrigação nas fontes nitrato de amônio e sulfato de potássio; T5 - Adubação nitrogenada e potássica aplicada via fertirrigação nas fontes nitrato de amônio e nitrato de potássio; T6 - Adubação nitrogenada e potássica aplicada via solo nas fontes ureia e cloreto de potássio de liberação controlada no período de outubro a março (período chuvoso) e adubação nitrogenada e potássica aplicada via fertirrigação, nas fontes nitrato de amônio e sulfato de potássio no período de abril a setembro (período seco). Foi monitorado o pH e condutividade elétrica da solução do solo, avaliações biométricas das plantas tais como altura, comprimento do primeiro ramo plagiotrópico e número de nós no primeiro ramo plagiotrópico, além da produção por planta e estimativa de produtividade. Os tratamentos T1 e T3 que utilizaram ureia e cloreto de potássio e o T4 - nitrato de amônio e sulfato de potássio disponibilizaram maiores quantidade de nitrogênio na forma amoniacal, causando maior acidificação do bulbo. Em contrapartida os tratamentos T2, T5 e T6 apresentaram menor acidificação, com diferença estatística significativa na variação do pH nas duas profundidades analisadas a partir de 18 meses da aplicação dos tratamentos. Nos tratamentos T2 e T6 observou-se menor salinidade inicial na avaliação aos 90 dias após o plantio através da leitura da condutividade elétrica da solução do solo. Para as avaliações biométricas, os tratamentos T2, T4, T5 e T6 diferiram estatisticamente dos tratamentos T1 e T3, influenciando positivamente à altura de plantas, comprimento e número de nós no primeiro ramo plagiotrópico.
Resumo:
Fertirrigation with phosphoric acid has been considered as an option to avoid drips from clogging. In some cases, this acid cause soil acidification and it can be substituted bypotassium hydroxide. This study had the objective of evaluating the effects of different phosphoric acid and potassium hydroxide doses, applied via fertirrigation, on soil fertility, plant nutrition and lettuce yield, compared to the conventional fertilization system. The experiment was carried out in greenhouse, in the College of Agricultural Sciences, FCA/UNESP, Botucatu-SP-Brazil. The experimental design was the completely randomized block, with 6 treatments and 4 replications. Treatments consisted of the combinations of doses (25% and 50% of the recommended complete dose for the lettuce) and application ofcomplete dose (100%) of phosphorus (P) and potassium (K) applied via fertirrigation, and a control (conventional fertilization system). The results showed that P and K availability in soil and nutrient concentration in plants were affected by treatments. Low phosphorus and potassium doses, applied via fertirrigation, were not efficient for the appropriate development of lettuce plants. The results showed that agronomic characteristics and commercial lettuce were affected by doses and application systems, especially the treatment with application of P and K full dose fertirrigation.
Resumo:
Objectives This study evaluated the heat strain experienced by armored vehicle officers (AVOs) wearing personal body armor (PBA) in a sub-tropical climate. Methods Twelve male AVOs, aged 35-58 years, undertook an eight hour shift while wearing PBA. Heart rate and core temperature were monitored continuously. Urine specific gravity (USG) was measured before and after, and with any urination during the shift. Results Heart rate indicated an intermittent and low-intensity nature of the work. USG revealed six AVOs were dehydrated from pre through post shift, and two others became dehydrated. Core temperature averaged 37.4 ± 0.3°C, with maximum's of 37.7 ± 0.2°C. Conclusions Despite increased age, body mass, and poor hydration practices, and Wet-Bulb Globe Temperatures in excess of 30°C; the intermittent nature and low intensity of the work prevented excessive heat strain from developing.
Resumo:
Bomb technicians perform their work while encapsulated in explosive ordnance disposal (EOD) suits. Designed primarily for safety, these suits have an unintended consequence of impairing the body’s natural mechanisms for heat dissipation. Purpose: To quantify the heat strain encountered during an EOD operational scenario in the tropical north of Australia. Methods: All active police male bomb technicians, located in a tropical region of Australia (n=4, experience 7 ± 2.1 yrs, age 34 ± 2 yrs, height 182.3 ± 5.4 cm, body mass 95 ± 4 kg, VO2max 46 ± 5.7 ml.kg-1.min-1) undertook an operational scenario wearing the Med-Eng EOD 9 suit and helmet (~32 kg). The climatic conditions ranged between 27.1–31.8°C ambient temperature, 66-88% relative humidity, and 30.7-34.3°C wet bulb globe temperature. The scenario involved searching a two story non air-conditioned building for a target; carrying and positioning equipment for taking an X-ray; carrying and positioning equipment to disrupt the target; and finally clearing the site. Core temperature and heart rate were continuously monitored, and were used to calculate a physiological strain index (PSI). Urine specific gravity (USG) assessed hydration status and heat associated symptomology were also recorded. Results: The scenario was completed in 121 ± 22 mins (23.4 ± 0.4% work, 76.5 ± 0.4% rest/recovery). Maximum core temperature (38.4 ± 0.2°C), heart rate (173 ± 5.4 bpm, 94 ± 3.3% max), PSI (7.1 ± 0.4) and USG (1.031 ± 0.002) were all elevated after the simulated operation. Heat associated symptomology highlighted that moderate-severe levels of fatigue and thirst were universally experienced, muscle weakness and heat sensations experienced by 75%, and one bomb technician reported confusion and light-headedness. Conclusion: All bomb technicians demonstrated moderate-high levels of heat strain, evidenced by elevated heart rate, core body temperature and PSI. Severe levels of dehydration and noteworthy heat-related symptoms further highlight the risks to health and safety faced by bomb technicians operating in tropical locations.
Resumo:
Explosive ordnance disposal (EOD) technicians are required to wear protective clothing to protect themselves from the threat of overpressure, fragmentation, impact and heat. The engineering requirements to minimise these threats results in an extremely heavy and cumbersome clothing ensemble that increases the internal heat generation of the wearer, while the clothing’s thermal properties reduce heat dissipation. This study aimed to evaluate the heat strain encountered wearing EOD protective clothing in simulated environmental extremes across a range of differing work intensities. Eight healthy males [age 25±6 years (mean ± sd), height 180±7 cm, body mass 79±9 kg, V˙O2max 57±6 ml.kg−1.min−1] undertook nine trials while wearing an EOD9 suit (weighing 33.4 kg). The trials involved walking on a treadmill at 2.5, 4 and 5.5 km⋅h−1 at each of the following environmental conditions, 21, 30 and 37°C wet bulb globe temperature (WBGT) in a randomised controlled crossover design. The trials were ceased if the participants’ core temperature reached 39°C, if heart rate exceeded 90% of maximum, if walking time reached 60 minutes or due to fatigue/nausea. Tolerance times ranged from 10–60 minutes and were significantly reduced in the higher walking speeds and environmental conditions. In a total of 15 trials (21%) participants completed 60 minutes of walking; however, this was predominantly at the slower walking speeds in the 21°C WBGT environment. Of the remaining 57 trials, 50 were ceased, due to attainment of 90% maximal heart rate. These near maximal heart rates resulted in moderate-high levels of physiological strain in all trials, despite core temperature only reaching 39°C in one of the 72 trials.
Resumo:
This study evaluated the physiological tolerance times when wearing explosive and chemical (>35kg) personal protective equipment (PPE) in simulated environmental extremes across a range of differing work intensities. Twelve healthy males undertook nine trials which involved walking on a treadmill at 2.5, 4 and 5.5 km.h-1 in the following environmental conditions, 21, 30 and 37 °C wet bulb globe temperature (WBGT). Participants exercised for 60 min or until volitional fatigue, core temperature reached 39 °C, or heart rate exceeded 90% of maximum. Tolerance time, core temperature, skin temperature, mean body temperature, heart rate and body mass loss were measured. Exercise time was reduced in the higher WBGT environments (WBGT37
Resumo:
Background Explosive ordnance disposal (EOD) technicians are often required to wear specialised clothing combinations that not only protect against the risk of explosion but also potential chemical contamination. This heavy (>35kg) and encapsulating ensemble is likely to increase physiological strain by increasing metabolic heat production and impairing heat dissipation. This study investigated the physiological tolerance times of two different chemical protective undergarments, commonly worn with EOD personal protective clothing, in a range of simulated environmental extremes and work intensities Methods Seven males performed eighteen trials wearing two ensembles. The trials involved walking on a treadmill at 2.5, 4 and 5.5 km.h-1 at each of the following environmental conditions, 21, 30 and 37°C wet bulb globe temperature (WBGT). The trials were ceased if the participants’ core temperature reached 39°C, if heart rate exceeded 90% of maximum, if walking time reached 60 minutes or due to volitional fatigue. Results Physiological tolerance times ranged from 8 to 60 min and the duration (mean difference: 2.78 min, P>0.05) were similar in both ensembles. A significant effect for environment (21>30>37°C WBGT, P<0.05) and work intensity (2.5>4>5.5 km.h-1, P< 0.05) was observed in tolerance time. The majority of trials across both ensembles (101/126; 80.1%) were terminated due to participants achieving a heart rate equivalent to greater than 90% of their maximum. Conclusions Physiological tolerance times wearing these two chemical protective undergarments, worn underneath EOD personal protective clothing, were similar and predominantly limited by cardiovascular strain.
Resumo:
Objective Explosive ordnance disposal (EOD) often requires technicians to wear multiple protective garments in challenging environmental conditions. The accumulative effect of increased metabolic cost coupled with decreased heat dissipation associated with these garments predisposes technicians to high levels of physiological strain. It has been proposed that a perceptual strain index (PeSI) using subjective ratings of thermal sensation and perceived exertion as surrogate measures of core body temperature and heart rate, may provide an accurate estimation of physiological strain. Therefore, this study aimed to determine if the PeSI could estimate the physiological strain index (PSI) across a range of metabolic workloads and environments while wearing heavy EOD and chemical protective clothing. Methods Eleven healthy males wore an EOD and chemical protective ensemble while walking on a treadmill at 2.5, 4 and 5.5 km·h− 1 at 1% grade in environmental conditions equivalent to wet bulb globe temperature (WBGT) 21, 30 and 37 °C. WBGT conditions were randomly presented and a maximum of three randomised treadmill walking trials were completed in a single testing day. Trials were ceased at a maximum of 60-min or until the attainment of termination criteria. A Pearson's correlation coefficient, mixed linear model, absolute agreement and receiver operating characteristic (ROC) curves were used to determine the relationship between the PeSI and PSI. Results A significant moderate relationship between the PeSI and the PSI was observed [r = 0.77; p < 0.001; mean difference = 0.8 ± 1.1 a.u. (modified 95% limits of agreement − 1.3 to 3.0)]. The ROC curves indicated that the PeSI had a good predictive power when used with two, single-threshold cut-offs to differentiate between low and high levels of physiological strain (area under curve: PSI three cut-off = 0.936 and seven cut-off = 0.841). Conclusions These findings support the use of the PeSI for monitoring physiological strain while wearing EOD and chemical protective clothing. However, future research is needed to confirm the validity of the PeSI for active EOD technicians operating in the field.
Resumo:
An adaptive conjoint analysis was use to evaluate stakeholders' opinion of welfare indicators for ship-transported sheep and cattle, both onboard and in pre-export depots. In consultations with two nominees of each identified stakeholder group (government officials, animal welfare representatives, animal scientists, stockpersons, producers/pre-export depot operators, exporters/ship owners and veterinarians), 18 potential indicators were identified Three levels were assigned to each using industry statistics and expert opinion, representing those observed on the best and worst 5% of voyages and an intermediate value. A computer-based questionnaire was completed by 135 stakeholders (48% of those invited). All indicators were ranked by respondents in the assigned order, except fodder intake, in which case providing the amount necessary to maintain bodyweight was rated better than over or underfeeding, and time in the pre-export assembly depot, in which case 5 days was rated better than 0 or 10 days. The respective Importance Values (a relative rating given by the respondent) for each indicator were, in order of declining importance: mortality (8.6%), clinical disease incidence (8.2%), respiration rate (6.8%), space allowance (6.2%), ammonia levels (6.1%), weight change (6.0%), wet bulb temperature (6.0%), time in assembly depot (5.4%), percentage of animals in hospital pen (5.4%), fodder intake (5.2%), stress-related metabolites (5.0%), percentage of feeding trough utilised (5.0%), injuries (4.8%), percentage of animals able to access food troughs at any one time (4.8%), percentage of animals lying down (4.7%), cortisol concentration (4.5Y.), noise (3.9y.), and photoperiod (3.4%). The different stakeholder groups were relatively consistent in their ranking of the indicators, with all groups nominating the some top two and at least five of the top seven indicators. Some of the top indicators, in particular mortality, disease incidence and temperature, are already recorded in the Australian industry, but the study identified potential new welfare indicators for exported livestock, such as space allowance and ammonia concentration, which could be used to improve welfare standards if validated by scientific data. The top indicators would also be useful worldwide for countries engaging in long distance sea transport of livestock.
Resumo:
This study compared the effects of a low-frequency electrical stimulation (LFES; Veinoplus® Sport, Ad Rem Technology, Paris, France), a low-frequency electrical stimulation combined with a cooling vest (LFESCR) and an active recovery combined with a cooling vest (ACTCR) as recovery strategies on performance (racing time and pacing strategies), physiologic and perceptual responses between two sprint kayak simulated races, in a hot environment (∼32 wet-bulb-globe temperature). Eight elite male kayakers performed two successive 1000-m kayak time trials (TT1 and TT2), separated by a short-term recovery period, including a 30-min of the respective recovery intervention protocol, in a randomized crossover design. Racing time, power output, and stroke rate were recorded for each time trial. Blood lactate concentration, pH, core, skin and body temperatures were measured before and after both TT1 and TT2 and at mid- and post-recovery intervention. Perceptual ratings of thermal sensation were also collected. LFESCR was associated with a very likely effect in performance restoration compared with ACTCR (99/0/1%) and LFES conditions (98/0/2%). LFESCR induced a significant decrease in body temperature and thermal sensation at post-recovery intervention, which is not observed in ACTCR condition. In conclusion, the combination of LFES and wearing a cooling vest (LFESCR) improves performance restoration between two 1000-m kayak time trials achieved by elite athletes, in the heat.
Resumo:
Thermodynamic parameters of the atmosphere form part of the input to numerical forecasting models. Usually these parameters are evaluated from a thermodynamic diagram. Here, a technique is developed to evaluate these parameters quickly and accurately using a Fortran program. This technique is tested with four sets of randomly selected data and the results are in agreement with the results from the conventional method. This technique is superior to the conventional method in three respects: more accuracy, less computation time, and evaluation of additional parameters. The computation time for all the parameters on a PC AT 286 machine is II sec. This software, with appropriate modifications, can be used, for verifying various lines on a thermodynamic diagram
Resumo:
A new objective climatology of polar lows in the Nordic (Norwegian and Barents) seas has been derived from a database of diagnostics of objectively identified cyclones spanning the period January 2000 to April 2004. There are two distinct parts to this study: the development of the objective climatology and a characterization of the dynamical forcing of the polar lows identified. Polar lows are an intense subset of polar mesocyclones. Polar mesocyclones are distinguished from other cyclones in the database as those that occur in cold air outbreaks over the open ocean. The difference between the wet-bulb potential temperature at 700 hPa and the sea surface temperature (SST) is found to be an effective discriminator between the atmospheric conditions associated with polar lows and other cyclones in the Nordic seas. A verification study shows that the objective identification method is reliable in the Nordic seas region. After demonstrating success at identifying polar lows using the above method, the dynamical forcing of the polar lows in the Nordic seas is characterized. Diagnostics of the ratio of mid-level vertical motion attributable to quasi-geostrophic forcing from upper and lower levels (U/L ratio) are used to determine the prevalence of a recently proposed category of extratropical cyclogenesis, type C, for which latent heat release is crucial to development. Thirty-one percent of the objectively identified polar low events (36 from 115) exceeded the U/L ratio of 4.0, previously identified as a threshold for type C cyclones. There is a contrast between polar lows to the north and south of the Nordic seas. In the southern Norwegian Sea, the population of polar low events is dominated by type C cyclones. These possess strong convection and weak low-level baroclinicity. Over the Barents and northern Norwegian seas, the well-known cyclogenesis types A and B dominate. These possess stronger low-level baroclinicity and weaker convection.