110 resultados para AUDIOMETRY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a review of a study to compare latencies of early evoked responses in young children with those of adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses several tests used to measure speech intelligibility and speech discrimination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper contains a speech discrimination test in the Russian language composed of fifty known Russian monosyllables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a review of speech audiometry materials in the following languages: English, Portuguese and Spanish.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses a study to assess and compare frequency audiometric thresholds obtained under two listening environments--a sound suite and a typical hospital room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses a study of noise levels in audiometric testing rooms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insert and circumaural earphones were used during visual reinforcement audiometry with children 12-to 24-months of age. Acceptance of earphones was determined by the number of ear specific thresholds obtained and by audiologist subjective ratings. Results indicate that children in this age range accept both types of earphones; however, significantly more ear specific thresholds were obtained using insert earphones compared to circumaural.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research set out to test three main hypotheses derived from a summary of literature relevant to the use of audiometry in industry. These hypotheses were: (1) performing audiometry increases the probability that hearing protectors, once issued, will be worn; (2) audiometry is considered by workers to be evidence of their employer's concern for their welfare; (3) audiometry is associated with common law claims by workers against employers for alleged occupational deafness. Six subsidiary hypotheses were also developed. Four methods of data collection were used: (1) attitude questionnaires were administered to samples of workers drawn from an industrial company performing audiometry and two industrial companies not performing audiometry; (2) a postal questionnaire was sent out to industrial medical officers; (3) surveys were undertaken to assess the proportion of the workforce in each of eight industrial companies that was wearing personal hearing protectors that had been provided; (4) structured interviews were carried out with relevant management level personnel in each of five industrial companies. Factor analysis was the main statistical analytic technique used. The data supported all three main hypotheses. Audiometry was also examined as an example of medical screening procedure. It was argued that the validation of medical screening procedures requires the satisfaction of attitudinal or motivational validation criteria in addition to the biological and economic criteria currently used. It was concluded that industrial audiometry failed to satisfy such attitudinal or motivational criteria and so should not be part of a programme of screening for occupational deafness. It was also concluded that industrial audiometry may be useful in creating awareness, amongst workers, of occupational deafness. It was argued that the only profitable approach to investigating the role of audiometry in preventing occupational deafness is to study the attitudes and perceptions of everyone involved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente estudo teve como objetivo descrever os achados audiológicos e genéticos de nove membros de uma família brasileira que apresenta a mutação no DNA mitocondrial. Todos os nove membros realizaram estudo genético, avaliação foniátrica e audiológica (audiometria tonal e logoaudiometria). O estudo genético revelou a presença de mutação mitocondrial A1555G no gene 12S rRNA (MT-RNR-1) do DNA mitocondrial em todos os sujeitos. Oito sujeitos apresentaram deficiência auditiva e somente um apresentou limiares auditivos normais até o término da realização do estudo. Os resultados audiológicos apontaram para perdas auditivas bilaterais, com prevalência das simétricas, de configurações e graus variados (de moderado a profundo) e pós-linguais. Progressão da perda auditiva foi observada em dois irmãos afetados. Não foi possível afirmar a época do início da perda auditiva por falta de informação dos sujeitos, no entanto, observou-se manifestação da perda em crianças e adultos. As mutações no DNA mitocondrial representam uma causa importante de perda auditiva, sendo imprescindível a realização do diagnóstico etiopatológico, a fim de retardar o início ou evitar a progressão da surdez.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TEMA: avaliação audiológica de pais de indivíduos com perda auditiva de herança autossômica recessiva. OBJETIVO: estudar o perfil audiológico de pais de indivíduos com perda auditiva, de herança autossômica recessiva, inferida pela história familial ou por testes moleculares que detectaram mutação no gene GJB2, responsável por codificar a Conexina 26. MÉTODO: 36 indivíduos entre 30 e 60 anos foram avaliados e divididos em dois grupos: grupo controle, sem queixas auditivas e sem história familiar de deficiência auditiva, e grupo de estudos composto por pais heterozigotos em relação a genes de surdez de herança autossômica recessiva inespecífica ou portadores heterozigotos de mutação no gene da Conexina 26. Todos foram submetidos à audiometria tonal liminar (0,25kHz a 8), audiometria de altas freqüências (9kHz a 20) e emissões otoacústicas produtos de distorção (EOAPD). RESULTADOS: houve diferenças significativas na amplitude das EOAPD nas freqüências 1001 e 1501Hz entre os grupos, sendo maior a amplitude no grupo controle. Não houve diferença significativa entre os grupos para os limiares tonais de 0,25 a 20KHz. CONCLUSÃO: as EOAPD foram mais eficazes, em comparação com a audiometria tonal liminar, para detectar diferenças auditivas entre os grupos. Mais pesquisas são necessárias para verificar a confiabilidade destes dados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We hypothesized that the processing of auditory information by the perisylvian polymicrogyric cortex may be different from the normal cortex. To characterize the auditory processing in bilateral perisylvian syndrome, we examined ten patients with perisylvian polymicrogyria (Group 1) and seven control children (Group 11). Group I was composed by four children with bilateral perisylvian polymicrogyria and six children with bilateral posterior perisylvian polymicrogyria. The evaluation included neurological and neuroimaging investigation, intellectual quotient and audiological assessment (audiometry and behavior auditory tests). The results revealed a statistically significant difference between the groups in the behavioral auditory tests, Such as, digits dichotic test, nonverbal dichotic test (specifically in right attention), and random gap detection/random gap detection expanded tests. Our data showed abnormalities in the auditory processing of children with perisylvian polymicrogyria, suggesting that perisylvian polymicrogyric cortex is functionally abnormal. We also found a correlation between the severity of our auditory findings and the extent of the cortical abnormality. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To determine the accuracy of the whispered voice test in detecting hearing impairment in adults and children. Design Systematic review of studies of test accuracy. Data sources Medline, Embase, Science Citation Index, unpublished theses, manual searching of bibliographies of known primary and review articles, and contact with authors. Study selection Two reviewers independently selected and extracted data on study characteristics, quality, and accuracy of studies. Studies were included if they had cross sectional designs, at least one of the index tests was the whispered voice test, and the reference test (audiometry) was performed on at least 80% of the participants. Data extraction Data were used to form 2x2 contingency tables with hearing impairment by audiometry as the reference standard. Data synthesis The eight studies that were found used six different techniques. The sensitivity in the four adult studies was 90% or 100% and the specificity was 70% to 87%. The sensitivity in the four childhood studies ranged from 80% to 96% and specificity ranged from 90% to 98%. Conclusion The whispered voice test is a simple and accurate test for detecting hearing impairment. There is some concern regarding the lower sensitivity in children and the overall reproducibility of the test, particularly in primary care settings. Further studies should be conducted in primary care settings to explore the influence of components of the testing procedure to optimise test sensitivity and to promote standardisation of the testing procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Long latency auditory evoked potentials (LLAEP) alterations in individuals with tinnitus are suggestive of dysfunction in the central auditory pathways at a cortical level. Aim: to characterize the LLAEP in individuals with and without tinnitus exposed to occupational noise. Method: Cross-sectional contemporary cohort, prospective study. Sixty subjects exposed to occupational noise, ranging in age from 29 to 50 years underwent LLAEP assessment; 30 of them had tinnitus complaint and 30 did not have tinnitus. Results: we observed significant statistical difference regarding the mean values of latencies of waves N1 (p<0.001), P2 (p=0.002) and P300 (p=0.039) when we compared individuals with and without tinnitus. In individuals with tinnitus we also noticed a greater number of altered results concerning components N1 (60%) and P2 (66.7%), although only component P2 presented significant statistical difference (p=0.010). For the LLAEP, the latency increase was the only type of alteration found (p=1.000). We found a greater association between bilateral tinnitus and bilateral alteration for all components N1(73%), P2(73%) and P300(50%). Conclusion: It is relevant to study LLAEP in individuals with tinnitus exposed to high occupational sound pressure levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tinnitus is a symptom present in approximately 15% of the world population. Most patients are between 40 and 80 years of age; the prevalence above 60 reaches 33%. About 20% have moderate to severe impact in the quality of life but the factors associated with the tinnitus annoyance are not completely known. Aim: The objective of this study is to evaluate the relationship between age, gender and hearing loss on tinnitus annoyance. Materials and methods: 68 patients were evaluated at the tinnitus center at our hospital, from March 2007 to march 2008, with a detailed interview, complete otolaryngological examination, the Portuguese version of the Tinnitus Handicap Inventory and pure tone audiometry. Results: Age varied from 24 to 83 (mean=59); the mean THI value was 39 (females: 36; males: 44). THI grades were: slight: 32.3%; mild: 19.1%; moderate: 20.6%; severe: 13.2% and catastrophic: 14.7%. No significant correlation was found between gender (p=0.30), age (p=0.77) hearing loss (p>0.05 for all averages analyzed) and tinnitus severity. Conclusion: Gender, age and hearing loss do not influence tinnitus annoyance, using the THI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. Aim: The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Study design: Contemporary cohort study. Materials and Methods: A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. Results: The prevalence of hearing loss was of 21.7%. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p=0.044), discomfort with the sound intensity in the work place (p=0.009) and intolerance to loud sound (p=0.029). Conclusions: There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.