436 resultados para ANSYS Workbench
Resumo:
Currently, finite element analyses are usually done by means of commercial software tools. Accuracy of analysis and computational time are two important factors in efficiency of these tools. This paper studies the effective parameters in computational time and accuracy of finite element analyses performed by ANSYS and provides the guidelines for the users of this software whenever they us this software for study on deformation of orthopedic bone plates or study on similar cases. It is not a fundamental scientific study and only shares the findings of the authors about structural analysis by means of ANSYS workbench. It gives an idea to the readers about improving the performance of the software and avoiding the traps. The solutions provided in this paper are not the only possible solutions of the problems and in similar cases there are other solutions which are not given in this paper. The parameters of solution method, material model, geometric model, mesh configuration, number of the analysis steps, program controlled parameters and computer settings are discussed through thoroughly in this paper.
Resumo:
According to the importance of rehabilitation and recovery of Architectural Heritage in the live of people, this paper is aimed to strengthen the traditional methods of stone vaults calculation taking advantage of the technological characteristics of the powerful program ANSYS Workbench. As an example of this, it could find out the possible pathologies that could arise during the construction history of the building. To limit this research, the upper vault of the main chapel of the Santiago parish church in Orihuela -Alicante- is selected as a reference which is a Jeronimo Quijano´s important building work in the XVI century in the Renaissance. Moreover, it is an innovative stone masonry vault that consists of 8 double intercrossed arches with each other and braced by severies. During the seventeenth century there was a lantern in the central cap and it is unknown why it was removed. Its construction could justify the original constructive solution with intercrossed arches that freed the center to create a more enlightened and comfortable presbytery. By similarity with other Quijano’s works, it is considered a small lantern drilling the central spherical cap. It is proposed to carry out a comparative study of it with different architectural solutions from the same period and based on several common parameters such as: a vault of square plant with spherical surround, intercrossed arches, a possible lantern, the dimension of the permitted space, similar states of loads and compact limestone masonry. The three solutions are mainly differentiated by their size and the type of lantern and its comparison lets us know which one is the most resistant and stable. The other two building works maintain some connection with the Quijano's professional scope. It has selected the particular case of the Communion chapel of the Basilica in Elche (a large prismatic lantern with a large cylindrical drum that starts from the own arches and an upper hemispherical dome), for its conservation, its proximity to Orihuela and its implementation during the century XVIII. Finally, a significant Dome Spanish Renaissance complete the selection: a cross vault of the Benavides Chapel of the Saint Francisco Convent in Baeza - Jaén-, designed by Andres of Vandelvira in the sixteenth century (a large hemispherical dome that starts from the own arcs). To simplify the calculation and standardize the work that have to be contrasted, all of them were considered with some similar characteristics: 30 cm constant thickness, the intercrossed arches were specifically analyzed and had identical loads, Young's modulus and Poisson's ratio. Regarding the calculation solutions, in general terms, the compressive stresses predominate, influencing on it the joint collaboration of the filling material on the vault, the vault itself, the thick side walls, the buttresses and the top cover weight . In addition, the three solutions are suitable, being the Orihuela one the safest and the Baeza one the riskiest for its large dimensions. Thus, the idea of intercrossed arches with suitable thickness would allow carry out the heaviest lantern and this would confirm it as a Renaissance architectural typology built in stone.
Resumo:
Hardness is defined as the resistance and load bearing capability of an item. Seat hardness is an important factor in seat comfort as it impacts on a number of variables including seat postural stability, postural control, pressure comfort as a result of tissue deformation, and occupant vibration. The development of the test rig further on described in this report will enable Futuris Automotive to develop their current comfort testing procedures and thus increase the comfort of their automotive seats. The test rig consists of a buttock indenter, which produces a controlled application of a load to a seat cushion with measured displacement via a linear indenter. In parallel with the physical property presented, an analytic (software) finite element tool was developed to simulate seat pressure in an ANSYS Workbench V13 environment. This report also details the procedure required for Futuris to accurately and precisely measure cushion hardness which will enhance their comfort testing procedures, product development and target settings. The report is divided into three main sections: 1 Test equipment specification (M4) - A detailed description of the process used to build the seat cushion indenter and a description of the indenter mechanical structure and electrical functionality (chapter 2). 2 Analytic tool specification (M5) – A detailed description of the CAE seat and indenter software tool, developed as a finite element model (FEM) under ANSYS Workbench V13 to simulate indentation of a physical seat cushion similar to the hardware tool (chapter 3). 3 Product Development and Comfort Design Procedure (M6) - The cushion hardness testing procedure to be used with the physical indenter. This milestone is partially incomplete, as it covers a description of the test procedure to be applied, however not the operating system (control software) required to operate the physical property (chapter 4). Although outside the scope of this project, this report also details the testing procedures required to measure overall seatback hardness.
Resumo:
Master Thesis in Mechanical Engineering field of Maintenance and Production
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The presence of porosities at the dentin/adhesive interface has been observed with the use of new generation dentin bonding systems. These porosities tend to contradict the concept that etching and hybridization processes occur equally and simultaneously. Therefore, the aim of this study was to evaluate the micromechanical behavior of the hybrid layer (HL) with voids based on a self-etching adhesive system using 3-D finite element (FE) analysis. Three FE models (Mr) were built: Mr, dentin specimen (41x41x82 μm) with a regular and perfect (i.e. pore-free) HL based on a self-etching adhesive system, restored with composite resin; Mp, similar to M, but containing 25% (v/v) voids in the HL; Mpp, similar to Mr, but containing 50% (v/v) voids in the HL. A tensile load (0.03N) was applied on top of the composite resin. The stress field was obtained by using Ansys Workbench 10.0. The nodes of the base of the specimen were constrained in the x, y and z axes. The maximum principal stress (σmax) was obtained for all structures at the dentin/adhesive interface. The Mpp showed the highest peak of σmax in the HL (32.2 MPa), followed by Mp (30 MPa) and Mr (28.4 MPa). The stress concentration in the peritubular dentin was high in all models (120 MPa). All other structures positioned far from voids showed similar increase of stress. Voids incorporated into the HL raised the σmax in this region by 13.5%. This behavior might be responsible for lower bond strengths of self-etching and single-bottle adhesives, as reported in the literature.
Resumo:
The aim of this study was to evaluate the influence of the high values of insertion torques on the stress and strain distribution in cortical and cancellous bones. Based on tomography imaging, a representative mathematical model of a partial maxilla was built using Mimics 11.11 and Solid Works 2010 softwares. Six models were built and each of them received an implant with one of the following insertion torques: 30, 40, 50, 60, 70 or 80 Ncm on the external hexagon. The cortical and cancellous bones were considered anisotropic. The bone/implant interface was considered perfectly bonded. The numerical analysis was carried out using Ansys Workbench 10.0. The convergence of analysis (6%) drove the mesh refinement. Maximum principal stress (σ max) and maximum principal strain (ε max) were obtained for cortical and cancellous bones around to implant. Pearson's correlation test was used to determine the correlation between insertion torque and stress concentration in the periimplant bone tissue, considering the significance level at 5%. The increase in the insertion torque generated an increase in the σ max and ε max values for cortical and cancellous bone. The σmax was smaller for the cancellous bone, with greater stress variation among the insertion torques. The ε max was higher in the cancellous bone in comparison to the cortical bone. According to the methodology used and the limits of this study, it can be concluded that higher insertion torques increased tensile and compressive stress concentrations in the periimplant bone tissue.
Resumo:
Objectives: Based on a maxillary premolar restored with laminate veneer and using the 3-D finite element analysis (FEA) and mCT data, the aim of this study was to evaluate the influence of different types of buccal cusp reduction on the stress distribution in the porcelain laminate veneer and in the resin luting cement layer. Methods: Two 3-D FEA models (M) of a maxillary premolar were built from mCT data. The buccal cusp reduction followed two configurations: Mt-buccal cusp completely covered by porcelain laminate veneer; and Mp-buccal cusp partially covered by porcelain laminate veneer. The loading (150 N in 458) was performed on the top of the buccal cusp. The finite element software (Ansys Workbench 10.0) was used to obtain the maximum shear stress (σmax) and maximum principal stress (σmax). Results: The Mp showed reduced the stress (σmax) in porcelain laminate veneer (from-2.3 to 24.5 MPa) in comparison with Mt (from-5.3 to 27.4 MPa). The difference between the peak and lower stress values of σmax in Mp (-6.8 to 26.7 MPa) and Mt (-5.3 to 27.4 MPa) was similar for the resin luting cement layer. The structures not exceeded the ultimate tensile strength or the shear bond strength. Conclusions: Cusp reduction did not affect significant increase in σmax and τmax. The Mt showed better stress distribution (τmax) than Mp. © 2011 Published by Elsevier Ireland on behalf of Japan Prosthodontic Society.
Resumo:
Purpose: To evaluate the stress distribution in peri-implant bone by simulating the effect of an implant with microthreads and platform switching on angled abutments through tridimensional finite element analysis. The postulated hypothesis was that the presence of microthreads and platform switching would reduce the stress concentration in the cortical bone. Methods: Four mathematical models of a central incisor supported by an implant (5.0mm×13mm) were created in which the type of thread surface in the neck portion (microthreaded or smooth) and the diameter of the angled abutment connection (5.0 and 4.1mm) were varied. These models included the RM (regular platform and microthreads), the RS (regular platform and smooth neck surface), the SM (platform switching and microthreads), and the SS (platform switching and smooth neck). The analysis was performed using ANSYS Workbench 10.0 (Swanson Analysis System). An oblique load (100N) was applied to the palatine surface of the central incisor. The bone/implant interface was considered to be perfectly integrated. Values for the maximum (σmax) and minimum (σmin) principal stress, the equivalent von Mises stress (σvM), and the maximum principal elastic strain (e{open}max) for cortical and trabecular bone were obtained. Results: For the cortical bone, the highest σmax (MPa) were observed for the RM (55.1), the RS (51.0), the SM (49.5), and the SS (44.8) models. The highest σvM (MPa) were found for the RM (45.4), the SM (42.1), the RS (38.7), and the SS models (37). The highest values for σmin were found for the RM, SM, RS and SS models. For the trabecular bone, the highest σmax values (MPa) were observed in the RS model (6.55), followed by the RM (6.37), SS (5.6), and SM (5.2) models. Conclusion: The hypothesis that the presence of microthreads and a switching platform would reduce the stress concentration in the cortical bone was partially rejected, mainly because the microthreads increased the stress concentration in cortical bone. Only platform switching reduced the stress in cortical bone. © 2012 Japan Prosthodontic Society.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Pós-graduação em Odontologia - FOA