1 resultado para machining robots

em Instituto Politécnico de Bragança


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental implant is used to replace the natural dental root. The process to fix the dental implant in the maxillary bone needs a previous drilling operation. This machining operation involves the increasing of temperature in the drilled region which can reach values higher than 47°C and for this temperature is possible to occur the osseous necrosis [I]. The main goal of this work is to implement an optimization method to define the optimal drilling parameters that could minimize the drilling temperature. The proposal optimization method is the Taguchi method. This method has been used with success in machining processes optimization of metallic materials [2]. However, the Taguchi method is also used in medical applications, namely in dental medicine [3].