3 resultados para Sensor Observation Service

em Reposit


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article analyzed whether the practices of hearing health care were consistent with the principles of universality, comprehensiveness and equity from the standpoint of professionals. It involved qualitative research conducted at a Medium Complexity Hearing Health Care Center. A social worker, three speech therapists, a physician and a psychologist constituted the study subjects. Interviews were conducted as well as observation registered in a field diary. The thematic analysis technique was used in the analysis of the material. The analysis of interviews resulted in the construction of the following themes: Universality and access to hearing health, Comprehensive Hearing Health Care and Hearing Health and Equity. The study identified issues that interfere with the quality of service and run counter to the principles of Brazilian Unified Health System. The conclusion reached was that a relatively simple investment in training and professional qualification can bring about significant changes in order to promote a more universal, comprehensive and equitable health service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first measurement of charmed-hadron (D(0)) production via the hadronic decay channel (D(0) → K(-) + π(+)) in Au+Au collisions at sqrt[s(NN)] = 200 GeV with the STAR experiment. The charm production cross section per nucleon-nucleon collision at midrapidity scales with the number of binary collisions, N(bin), from p+p to central Au+Au collisions. The D(0) meson yields in central Au + Au collisions are strongly suppressed compared to those in p+p scaled by N(bin), for transverse momenta p(T) > 3 GeV/c, demonstrating significant energy loss of charm quarks in the hot and dense medium. An enhancement at intermediate p(T) is also observed. Model calculations including strong charm-medium interactions and coalescence hadronization describe our measurements.